Introduction to Bubble Chamber: Introduction to Bubble Chamber:

Introduction to Bubble Chamber: - PowerPoint Presentation

SkylineBabe
SkylineBabe . @SkylineBabe
Follow
343 views
Uploaded On 2022-08-04

Introduction to Bubble Chamber: - PPT Presentation

Ops Training https wikijlaborgciswikiindexphpBubbleChamber September 9 2015 Nucleosynthesis and 12 C a g 16 O Reaction Time Reversal Reaction 16 O g ID: 935118

chamber beam mev bubble beam chamber bubble mev energy bremsstrahlung cross test section 16o liquid gas 100 kev nucleosynthesis

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Introduction to Bubble Chamber:" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

Introduction to Bubble Chamber:Ops Training

https://wiki.jlab.org/ciswiki/index.php/Bubble_Chamber

September

9

,

2015

Slide2

Nucleosynthesis

and 12C(

a

,g)16O ReactionTime Reversal Reaction: 16O(g,a)12CBubble ChamberElectron Beam RequirementsBremsstrahlung BeamPenfold-Leiss Cross Section UnfoldingBubble Chamber Test PlansBubble Chamber Safety

Outline

2

Slide3

Relative Abundance of Elements by Weight

3

This region is bypassed by 3

a process

Slide4

Big Bang Nucleosynthesis:

quark ̶ gluon plasma → p, n, He

Stellar

Nucleosynthesis: H burning, He burning, NCO cycle Supernovae Nucleosynthesis: Si burningCosmic Ray SpallationNucleosynthesis

4

Slide5

Nucleosynthesis and

12

C

(a,g)16O5Stellar Helium burningThe holy grail of nuclear astrophysics:

Affects synthesis of most of

elements in periodic

table

Sets

N(

12

C)/N(

16

O) (

0.4) ratio

in

universe

Determines

minimum

mass

star

requires to become

supernova

Slide6

6

Previous cross section measurements

:

Helium ions on carbon target: 12C(a,g)16OCarbon ions on helium gas: 4He(12C, g)16O or 4He(12C,16O)g Define S-Factor to remove both 1/E dependence of nuclear cross sections and Coulomb barrier transmission probability:

Heroic Efforts in Search of

12

C

(

a

,

g

)

16

O

R-

m

atrix Extrapolation

to stellar

helium burning at

E = 300

keV

Author

S

tot

(300)

(keV b

)

Hammer (2005)

162±39

Kunz (2001)

165

±50

Slide7

New Approach: Reversal Reaction + Bubble Chamber

7

+ 16O → 12C + 

beam

target

signal

Extra gain (factor of 100) by measuring time reversal

reaction

Bremsstrahlung at JLab

10

9

g

/s (top 250 keV

)

Target density up to 10

4

higher than conventional targets.

Number of

16

O nuclei =

/cm

2

(3.0 cm cell

)

Electromagnetic

debris

(electrons

and gammas, or positrons)

do NOT trigger nucleation (

detector

is insensitive to

g

-rays

by at

least 1 part in 10

11

)

 

Stellar

helium burning

at

E = 300 keV, T=200 106 K

MeV

Slide8

The Bubble Chamber

8

Critical point

309

1051

1

2

3

Liquid

Vapor

1 Cell is cooled then filled with room temperature gas

2 Gas is cooled and condenses into liquid

3 Once cell is completely filled with liquid, pressure is reduced creating a superheated liquid

3 Nuclear reactions induce bubble nucleation

2 High speed camera detects bubble and

repressurizes

3 System depressurizes and ready for another cycle

Slide9

N

2O (Laughing Gas) Bubble Chamber

9

T = -10˚CP = 50 atm

Slide10

10

User Interface

Slide11

Bubble Growth and Quenching

11

100 Hz Digital

Camera Dt = 10 ms3.0 cmN2O Chamber with PuC

neutron source

Slide12

Electron Beam Requirements

Beam Properties at Radiator:

Beam Kinetic Energy, (MeV)

7.9 – 8.5

Beam Current (µA)

0.01

– 100

Absolute Beam Energy Uncertainty

<0.1%

Relative Beam Energy Uncertainty

<0.02%

Energy Resolution (Spread),

σ

T

/T

<0.06%

Beam Size,

σ

x,y

(mm)

1

Polarization

None

12

Slide13

Bremsstrahlung Beam

13

Use

both GEANT4 and FLUKA to calculate Bremsstrahlung spectra (we will not measure Bremsstrahlung spectra)Monte Carlo simulation of Bremsstrahlung at radiotherapy energies is well studied, accuracy: ±5%

Bremsstrahlung Peaks

16

O(

g,a

)

12

C is ideal case for Bremsstrahlung beam

and

Penfold–Leiss Unfolding:

Very steep cross section; only

photons near

endpoint

contribute to

yield

No-structure (resonances)

Slide14

Penfold-Leiss Cross Section Unfolding

14

Measure yields at:

where, ,

S

olution can be written in two forms:

Or, Matrix form

:

 

Method

of

Quadratures: numerical solution

of

integral

equation based on

replacement

of

integral

by finite

sum

Volterra

Integral Equation of First Kind

Slide15

15

JLab Projected

12

C(a,g)16O S-Factor Statistical Error: dominated by background subtraction from 18O(g,a)14C (depletion = 5,000)

ElectronBeam

K. E.

Gamma

Energy

(MeV)

E

CM

(MeV)

Cross

Section

(

nb

)

S

tot

Factor

(keV b)Stat

Error(%)Sys

Error(Total, %)7.97.850.690.04662.224.5

15.38.0

7.950.790.185

48.7

20.7

13.5

8.1

8.05

0.89

0.58

41.8

14.7

12.2

8.2

8.15

0.99

1.53

35.5

13.8

11.48.38.251.093.4932.0

13.310.78.4

8.351.197.228.8

13.810.58.58.451.2913.626.314.810.1

Slide16

16

Slide17

Test Beamline

17

Slide18

Schematics of Test Beamline

18

P

ower deposited in radiator (100 µA and 8.5 MeV) : 6 mm: Energy loss = 8.5 MeV, P = 850 WPure Copper and Aluminum (high neutron threshold):63C(g,n) threshold = 10.86 MeV27Al(

g,n) threshold = 13.06 MeV

Electron K.E.

7.9 – 8.5 MeV

0.01 –

1

00 µA

Al Beam Pipe

Cu

Radiator/Dump

6

mm

Bubble Chamber

Superheated N

2

O

3 cm long

-10°C, 50 atm

Al Photon Dump

4

0 cm long

Cu Photon

Collimator

Ceramic

Insulator

Slide19

19

5 MeV

Dipole

5D SpectrometerBubbleChamberlocation

Slide20

20

Al Photon Dump

Cu Photon Collimator

Cu Electron Radiator/Dump

Slide21

21

Slide22

Measuring Absolute Beam Energy

22

Beam Position Monitor (BPM)

5 MeV

Dipole

Electron Beam

Momentum

Installed new higher field

dipole with better uniformity

Installed new Hall probe:

0.01% accuracy, resolution

to 2 ppm, and a temperature

stability of 10 ppm/°C

Still need to shield Earth’s

and other stray magnetic fields

Slide23

Beamline was ready since

Fall 2014

Approved

to run 10 μA CW and total energy of 10 MeVCompleted hot checkout and beam checkoutBeam Studies completed so far:Delivered 10.0 μA and 9.65 MeV (kinetic) for 5 hours in August 2015Measured beam momentum at different ¼ cryo-unit settingsMeasured beam charge at different beam currentsRe-doing realistic thermal analysis to run at 100 μA

Test Beamline Commissioning

23

Slide24

Fill with natural N

2O – test bubble chamber systems operation

Study Chamber with beam

(1:00 – 11:00 pm, Sept 10 – 18)Background measurementsFill with C2F6 – test bubble chamber systems operationWith beam (planned in Oct 16 – 22, 2015)Measure 19F(g,a)15N (Q = +4.013 MeV)

Compare measured cross section to our HIGS data

Fluorine is suitable for a first Penfold-Leiss unfolding:

Only one stable natural isotope (

19

F)

Low electron beam kinetic energy (4.6 – 5.2 MeV) – below threshold of any background

reaction

Bubble Chamber Test Plans

24

Slide25

Bubble Chamber Safety Reviews

Superheated liquid: N

2

O, Nitrous oxide (laughing gas)Colorless, non-flammable gas, with slightly sweet odor and tasteHigh pressure system:Design Authority: Dave MeekinsT = -10˚CP = 50 atm Buffer liquid: MercuryClosed systemVolume: 150 mLBubble Chamber Safety Review was on Aug 18, 2015Temporary Operational

Safety Procedures (TOSP) is approved

25

0

O

X

0

2

0

0

3

C

hemical

R

eactivity

Flammability

Health Hazard

Special Hazards:

Oxidizer

, allows chemicals to burn without an air supply