/
IR-4 NORTH CENTRAL REGION LABORATORY IR-4 NORTH CENTRAL REGION LABORATORY

IR-4 NORTH CENTRAL REGION LABORATORY - PowerPoint Presentation

SmilingSunshine
SmilingSunshine . @SmilingSunshine
Follow
343 views
Uploaded On 2022-07-28

IR-4 NORTH CENTRAL REGION LABORATORY - PPT Presentation

Method Development for Flonicamid on Prickly Pear Lester Geissel Sima Kumar Ingredients Hibiscus Flower reduce blood pressure Chamomile Flower reduce anxiety Orange Peel Natural Flavor ID: 930583

acetate ethyl water steps ethyl acetate steps water peaks pear tfna partition clean prickly recovery method control c18 column

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "IR-4 NORTH CENTRAL REGION LABORATORY" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

IR-4 NORTH CENTRAL REGION LABORATORY

Method Development for Flonicamid on Prickly Pear

Lester Geissel,

Sima

Kumar

Slide2

Slide3

Slide4

Ingredients

:

Hibiscus Flower

(reduce blood pressure)

Chamomile Flower

(reduce anxiety)

Orange Peel

Natural Flavor

Sunflower Lecithin

Soy Lecithin

Slide5

THE PROBLEM

SOLUTIONS ATTEMPTED

RESULTS OF ATTEMPTS

Slide6

FLONICAMID AND THREE METABOLITES

TFNA

TFNG

TFNA-AM

FOLLOWED REFERENCE METHOD

- Two cleanup steps: C18 SPE column, and ethyl acetate partition

- First control showed significant interference or contamination for: TFNA and TFNA-AM

Method Development

Slide7

PSA (3-AMINOPROPYL FUNCTIONALIZED SILICA GEL) CLEAN UP AT

0.2G AND 0.4G

No improvement

SOLVENT BLANK THROUGH REFERENCE METHOD

Came up clean

TRIAL CONTROL WITH GLASSWARE FROM SOLVENT BLANK TEST

Peaks still present

Steps

Slide8

TRIED CONTROL FROM INITIAL TRIAL AND ONE FROM EACH REMAINING TRIAL

All peaks still present

CONTACTED CA LAB - THEY SENT THEIR FLONICAMID ON HOPS

Had the C18 and ethyl acetate clean up, plus additional Nexus SPE clean up column

Peaks still present

Steps

Slide9

Steps

HORROCK'S FARM MARKET

They sold prickly pear pads - some were purchased for test run

RAN HORROCK'S PRICKLY PEAR PADS

Results were good - no peaks

Slide10

Recovery Issues

- Spiked blank solutions at various points

- Loss occurring during evaporation steps

- N-EVAP was taking a long time for evaporation of:

-

Acetonitrile:water

after C18 column

- Ethyl acetate from the partition

Slide11

Recovery Issues

Tried

:

- increasing bore size of N-EVAP needles

- increasing water bath from 45C to 50C

Result

:

- This combo slightly improved recoveries

Increased recovery with 1ml of water added before

evap

of ethyl acetate

Also collected fourth ethyl acetate partition and found small amount of analytes (added fourth partition to working outline)

Slide12

Using the

Turbovap

, we tried:

- addition of 0.5ml of water to the ethyl acetate

- water bath temp set at 50C

Result:

- Evaporation rate increased

- Recovery in acceptable range

CA Working Outline mentioned

Turbovap

Slide13

Prickly

Beyond

Com-pear

Slide14

SIMA KUMAR

LC/MS/MS Analyst