To learn more about our nursing Infusion education visit To learn more about our nursing Infusion education visit

To learn more about our nursing Infusion education visit - PDF document

adah
adah . @adah
Follow
345 views
Uploaded On 2021-10-01

To learn more about our nursing Infusion education visit - PPT Presentation

httppedagogyeducationcominfusionPeripheral IV Catheter ChartAlways select the smallestgauge peripheral catheter that will accommodate the prescribed therapy and patient need Peripheral catheters la ID: 891645

fluid min transfusion blood min fluid blood transfusion rapid catheter flow infusion trauma peripheral rates infusions neonate patient replacement

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "To learn more about our nursing Infusion..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 To learn more about our nursing Infusion
To learn more about our nursing Infusion education, visit http://pedagogyeducation.com/infusion Peripheral IV Catheter Chart Always select the smallest gauge peripheral catheter that will accommodate the prescribed therapy and patient need. Peripheral catheters larger than 20G are more likely to cause phlebitis. Do not use peripheral veins for continuous infusions of vesicants, parenteral nutrition or infusates with an osmolarity of 900 mOsm/L . 1 External catheter diameters, length and water flow rates are variable among each brand of catheter, with the dimensions and flow rates listed below being app roximate. Fluid flow rates in actual patient use, are influenced by the type and viscosity of fluid, fluid temperature, height of the container and the use of needleless connectors. 2 There are numerous factors that could also affect fluid flow rates, once the catheter is inserted into a patient. Reference s : Infusion Therapy Standards of Practice Jan/Feb 2016 1 https://www.bd.com/infusion/products/ivcatheters/iagbc/videos/pdfs/iagbc_wp3.pdf 2 * varies by specific catheter and manufacturer Color Gauge Size External Diameter (mm) * Length (mm) * Water Flow Rate (mL/min) * Recommended Uses Orange 14G 2.1 mm 45mm ~ 240 mL/min Trauma , Rapid blood transfusion , Surgery 1 Gray 16G 1.8 mm 45mm ~ 180 mL/min Rapid fluid replacement , Trauma , Rapid blood transfusion 1 Green 18G 1.3 mm 32mm ~ 90 mL/min Rapid fluid replacement , Trauma , Rapid blood transfusion 1 Pink 20G 1.1 mm 32mm ~ 60 mL/min Most infusions , Rapid fluid replacement , Trauma , Routine blood transfusion 1 Blue 22G 0.9 mm 25mm ~ 36 mL/min Most infusions Neonate, pediatric, older adults Routine blood transfusion 1 Yellow 24G 0.7mm 19mm ~ 20 mL/min Most infusions Neonate, pediatric, older adults, Routine blood transfusion, Neonate or Pediatric blood transfusion 1 Purple 26G 0.6 mm 19mm ~ 13 mL/min Pediatrics , Neonate 1