/
PX  and PX  TRMS three and single phase digital wattmeters For measurements onsite or PX  and PX  TRMS three and single phase digital wattmeters For measurements onsite or

PX and PX TRMS three and single phase digital wattmeters For measurements onsite or - PDF document

briana-ranney
briana-ranney . @briana-ranney
Follow
562 views
Uploaded On 2014-12-22

PX and PX TRMS three and single phase digital wattmeters For measurements onsite or - PPT Presentation

Excellent readability 3 quantities displayed simultaneously with a digit height of 14 mm Digital transmissions protected by infrared communication interface Mains power supply optional brPage 2br ottering contacts are a thing of the past the connect ID: 28060

Excellent readability quantities

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "PX and PX TRMS three and single phase ..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

For measurements on-site or in a laboratory, ¥¥¥¥¥ DC or AC TRMS networks: balanced single-phase (PX 110) or three-phase (PX 120) Â¥ ltage, current, active/reactive/apparent powers and power factor measurements Â¥ High degree of sensitivity Â¥ Simple and quick implementation with direct access keys Â¥ Numerous automatic functions: current range switching, HOLD, filtering, starting current, etc. Â¥ Excellent readability: 3 quantities displayed simultaneously with Â¥ Digital transmissions protected by infrared communication interface Â¥ Mains power supply (optional) ottering contacts are a thing ofperformed merely by a mag- sensitivity, the PX 120 and PX 110 arevocational training; examples of which areinstallers and comdepartments. To be more precise, theirability to measure RMS values in AC + DCmeasurements in the 4 quadrants on sig-nals which are disturbed and polluted bytalking about a new breed of instrument:The only difference between the two mod-els is that the PX 120 measures powersusing the three-phase three balanced wiresystem, whereas the PX 110 is reserved for Smoothing function The SMOOTH function is very useful fromthe moment the measurement in questionmeasurements with a time constant ofapproximately 3 seconds. Display stabilitythen goes from 5 counts to 2 counts. Exceptional readability In addition to a particularly large digit size(14 mm), the readout unit of the PX 1209,999 counts (4 digits) on three lines. Theuser thus simultaneously displays threevalues. Two different tables then suffice todisplay all the quantities measured by thedifferent symbols which, at any moment,battery. Protected digitallink and software The PX 120 and 110 have an infrared digitalnection into place. Moreover, this trans-improved safety; besides, the PX 120 and110 comply with the IEC 61010-1 standardA processing software package thenenables different quantities to bedisplayed on the screen of a PC, screenmeasurement files to be transferred to aspreadsheet and stored. User comfort and sturdiness Their casing reinforced with an elastomerhandholding capability and a sturdinessstand allows the instrument to be proppedto read the results. This stand is retractedwhen measurements are carried out on site. Easy implementation Although they offer elaborate functions, thePX 120 and PX 110 are very simple to(PX 120) keys corresponds to a singlethen accessible via a single press of thekey. Finally, the automatic change of rangebe powered by batteries or the mainspower supply. Starting current There are loads, such as engines, someheating resistors or lighting systems which,rush of current. Although they last only ashort time, these currents can triggerinstallation. To counter this, the PX 120and PX 110 are provided with the INRUSHmeasured). PX 120 and PX 110: TRMS three- and singlephase digital wattmeters Accessories and information required for orderingAccessories included Basically, each wattmeter is delivered with 2 voltage cables (1 red, 1 black), two 20 A current cables, 2 test probes (1 red, 1 black), 6 batteries, a verification Accessories available as optional extras HX0011 Wattmeter switch HX0012 Multiratio AC transformer (10, 15 and 30 A) HX0013 Data acquisition and processing software package* HX0021 * Includes the software package on CD and the RS 232 optical lead. To PX0120 DC/AC three-phase three balanced wire digital wattmeter PX0110 DC/AC single-phase digital wattmeter More than a wattmeter, and processing softwareBalanced three-phaseBattery rundownStarting current modeare as much at ease on a table as in yourWith the 73 x 54.3 mm LCD display, the user knows whatthe situation is at a glance. The battery rundown indicatorlight warns him when the period of autonomy is down toone hour. 906 211 012 - Ed. 2 - VS 1/02 single-phase and three-phase 3 balanced wire (T3FE)Number of counts3 lines of 4 digits (14 mm)3 lines of 4 digits (14 mm)BandwidthDC to 1 kHzDC to 1 kHz Range10 W to 1 kW Ð 1 kW to 6 kW10 W to 1 kW Ð 1 kW to 6 kWResolution0.1 W Ð 1 W0.1 W Ð 1 WBasic AC / DC accuracy1.5% R ±2 digits / 2.5% R ±5 digits1.5% R ±2 digits / 2.5% R ±5 digits Apparent/reactive power* Range10 to 1 k Ð 1k to 6 k10 to 1 k Ð 1k to 6 kResolution / Basic accuracy VA1.5% R ±2 digits / 1% R ±2 digits1.5% R ±2 digits / 1% R ±2 digitsResolution / Basic accuracy VAR2% R ±2 digits2% R ±2 digits Power factor Range1.001.00Resolution0.01 / 3% R ±2 digits0.01 / 3% R ±2 digits Vo Range0.5 to 600 V RMS0.5 to 600 V RMSResolution100 mV100 mVBasic AC/DC accuracy0.5% R ±2 digits / 1% R ±3 digits0.5% R ±2 digits / 1% R ±3 digitsInput impedance1 M Current Range10 mA to 2 A - 2 A to 10 A RMS10 mA to 2 A - 2 A to 10 A RMSResolution1 mA Ð 10 mA1 mA Ð 10 mABasic AC/DC accuracy0.7% R ±5 digits / 1.5% R ±5 digits0.7% R ±5 digits / 1.5% R ±5 digits Starting current Range5 A Ð 65 A (peak)5 A Ð 65 A (peak)Resolution / Accuracy100 mA / 10% R ±2 digits100 mA / 10% R ±2 digits TECHNICAL CHARACTERISTICSPX 120PX 110 Interfaces and softwareyesyesOperating temperature0 to 50¡C0 to 50¡CStorage temperature-40 to 70¡C-40 to 70¡CPower supply6 batteries of 1.5 V (LR6) / mains6 batteries of 1.5 V (LR6) / mainsAutonomy40 hours40 hoursDimensions (depth x length x height)60 x 108 x 211 mm60 x 108 x 211 mmight835 g835 gIEC 61010 safety standard600 V, Cat. III, pollution level 2600 V, Cat. III, pollution level 2Guarantee1 year1 year GENERAL CHARACTERISTICSPX 120PX 110 *Apparent power = VA Ð reactive power = VAR Ð In three-phase, the measurement is only exact for sinusoidal signals. For assistance and ordering Characteristics subject to modifications according to technological developments. FRANCE 190, rue Championnet75876 PARIS Cedex 18el: +33 1 44 85 44 86e-mail: export@chauvin-arnoux.frwww.chauvin-arnoux.fr UNITED KINGDOM /Chauvin Arnoux Ltd aldeck House -Waldeck Roade-mail: info@chauvin-arnoux.co.ukwww.chauvin-arnoux.co.uk PX 120 and PX 110: TRMS three- and singlephase digital wattmeters