KABEVETTEDrawing on our long years of experience in medical technology KABE LABORTECHNIK develops and produces highquality consumables for the daily work in clinic medical practice and laboratory At ID: 861210

blood item volume collection item blood collection volume tube pcs box homocysteine 772 kabe labortechnik sampling 150 tubes sample

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "by KABE LABORTECHNIK" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 by KABE LABORTECHNIK KABEVETTE® Drawing
by KABE LABORTECHNIK KABEVETTE® Drawing on our long years of experience in medical technology, KABE LABORTECHNIK develops and produces high-quality consumables for the daily work in clinic, medical practice and laboratory. At the same time, it is our aim to offer our customers and partners innovative and optimal solutions that make every day work simpler, safer and more ef cient.Perfection right down to the smallest detail, hygienically immaculate conditions and a consistent quality management have the highest priority in manufacturing our products. Our quality management system, established on the international standard DIN EN ISO 13485 is constantly reviewed

2 by our noti ed body and authorises
by our noti ed body and authorises us to label our products with the CE mark. Although our products are mass-produced, each item is subjected to the high requirements of a made-to-order production.As varied the duties are in which our products are put to use, as manifold is our product range. This bro-chure provides you with a comprehensive overview of our product range of the venous blood collection Quality, reliability and 3 Table of contents Available drawing volumes and N blood gas analysis The closed, drip-free system with rubber membrane for Aspiration principle for gentle collection particularly from patients with difficult vein conditionsNo dripping

3 after single or multiple collectionAdapt
after single or multiple collectionAdapter with safety catch provides a safe connection High-quality rubber membrane closure guarantees To open the tube, the stopper can easily be turned or tilted off The overlapping stopper reduces the risk of contamination Tubes can be closed again without any difficultiesVacuum technique: Through pre-aspiration of the tube a “fresh” vacuum with an exact filling volume can be generated. Prior to the blood collection pull down the piston completely until it is engaged and break it offCollection tube for direct handling on analysis systems Turnable or tiltable stopper Safety catch 5 7.5 ml Ø 15 x 92 mm5.5 ml Ø 15 x 75 mm

4 5 ml Ø 13 x 100 mm4.9 ml Ø 13 x 92 mm3
5 ml Ø 13 x 100 mm4.9 ml Ø 13 x 92 mm3.5 ml Ø 13 x 72 mm1.6 ml Ø 13 x 72 mm2.8 ml Ø 8.4 x 130 mmAvailable drawing volumes and tube sizes 6 Packing unit: 50 pcs in dispenser box, 500 pcs in boxWe can provide all stopper colours with international colour code in accordance to appendix F “Recommended colour codes for identifying additives and accessories” of DIN EN ISO 6710.Centrifugation recommendation: 2,000 g, 10 min – Serum and heparin plasma 2,500 g, 10 min – Serum and heparin plasma for tubes with separating gel Fill. EDTA PHC/PFA uorideCitrate NaF Item no.Item no.Item no.Item no.Item no.Item no. Item no.Item no.Item no.Item no.

5 Item no.Item no.Item no. 7.5 mlØ 15 x 9
Item no.Item no.Item no. 7.5 mlØ 15 x 92 mm102600S 792 G 7.5102800S 792 G 7.5 Gel103200P 792 G 7.5 Li103000P 792 G 7.5 AH102200E 792 G 7.5102375CPDA-1 792 G 95.5 mlØ 15 x 75 mm102825S 775 G 5.5 Gel5 mlØ 13 x 100 mm102690S 710 G 5102890S 710 G 5 Gel103290P 710 G 5 Li102390E 710 G 54.9 mlØ 13 x 92 mm102700S 790 G 4.9102900S 790 G 4.9 Gel103300P 790 G 4.9 Li102300E 790 G 4.9 102100C 790 G 5.5 3.5 mlØ 13 x 72 mm102725S 772 G 3.5102925S 772 G 3.5 Gel103325P 772 G 3.5 Li102325E 772 G 3.5 PHC/PFA 772 G 4 1.6 mlØ 13 x 72 mm102735S 772 G 1.6102330E 772 G 1.6 BZ 772 G 1,8 NaF Ø 8.5 x 130 mm 103475BSG 312 G 3.5 7 No more drawing blood than necessaryThe so-called Pat

6 ient Blood Management is an individual t
ient Blood Management is an individual treatment concept for a more conscious patient care particularly in clinical routine The concept provides a careful handling of patient’s own blood to prevent a clinic-associated anaemia. Risk factors that usually lead to blood transfusions shall be reduced through Patient Blood Management, because transfusions of allogenic blood can have negative side-effects as a consequence In addition to avoiding transfusions, for example through an early treatment of an already existing anaemia, blood collection before surgery can be carried out more carefully to prohibit a clinic-associated anaemia. This can be achieved through sampli

7 ng frequency, sampling routine as well a
ng frequency, sampling routine as well as reducing of the sampling volume.The portfolio of KABE LABORTECHNIK GmbH meets the demands of less blood volume and offers different types of tubes with minor If you have any questions or requests regarding Patient Blood Management, please contact us! Fill. EDTA PHC/PFA uorideCitrate NaF Item no.Item no.Item no.Item no.Item no.Item no. Item no.Item no.Item no.Item no.Item no.Item no.Item no. Ø 15 x 92 mm 102100C 790 G 5.5 Ø 13 x 72 mm PHC/PFA 772 G 4 Ø 13 x 72 mm BZ 772 G 1,8 NaF Ø 8.5 x 130 mm 103475BSG 312 G 3.5 Hans Gombotz, Kai D Zacharowski, Donat Spahn: Patient Blood Management. Thieme Verlag, Stuttgart 20

8 13, ISBN 978-3-131-70621-8. Delaney M,
13, ISBN 978-3-131-70621-8. Delaney M, Wendel S, Bercovitz RS, Cid J, Cohn C, Dunbar NM, et al. Transfusion reactions: prevention, diagnosis, and treatment. The Lancet. 2016;388(10061):2825-36. Mixing ratio: 1:10 G 9 ml prepared for haematological Anticoagulant: CPDA-1Fill. volume: 7.5 ml G 4 ml prepared for the determination of the platelet-dependent haemostasis capacity (PHC/PFA)Anticoagulant: sodium citrate 3.8 %Mixing ratio: 1:10Fill.volume: 3.5 mlPHC/PFA Item no. Item no. 9 G Homocysteine 3.5 ml prepared for the Anticoagulant: EDTA (stabilised)Fill. volume: 3.5 ml3.5 ml, Ø 13 mm, L = 72 mm Item no. 1 The homocysteine blood collection tube from KABE LABOR

9 TECHNIK was especially developed to simp
TECHNIK was especially developed to simplify the preanalytical procedures of homocys-teine testing. In order to measure homocysteine values reliably, it is neces-sary to either separate the blood cells as quickly as possible (within 30 minutes after sampling) from serum/plasma or to put the whole blood sample immediately on crushed ice. This handling procedure however, is often impractical in a surgical clinical The homocysteine blood collection tube can simplify this preanalytical procedure enormously. The purpose-developed stabiliser keeps the homocysteine value stable for No storage on crushed ice No cool transportation No dilution and volume effectsTiming of blo

10 od collection and transportation duratio
od collection and transportation duration have no effect on measure-ment resultsSuitable for overnight Easy to perform pre- analytics – same handling as standard Lit: 40 (2007) 739 – 743 „Clinical Evaluation of a new blood collection tube for the accuracy of total homocysteine measurement by different methods“ 10th International Conference One Carbon Metabolism, Vitamins B and Homocysteine, Nancy 2015: „The suitability ofKabevette sample collection tubes for measurment of total homocysteine using the Abbott Architect chemiluminescence method“ Clin Chem 53, No. 12 (2007) 2217 – 2218 „Stability of Plasma Homocysteine, S-Ad

11 enosylmethionine, and S-Adenosylhomocyst
enosylmethionine, and S-Adenosylhomocysteine in EDTA. Acidic Citrate, and Primavette ™ Collection Tubes, s.a.6th Conference on Homocysteine Metabolism, World Congress on Hyperhomcysteinemia, Saarbrücken 2007 G 3.5 ml prepared for the measurement Anticoagulant: sodium citrate 3.8 %Mixing ratio: 1:5Fill. volume: 2.8 mlMix the blood sample very well. Insert the ESR-KABEVETTEinto the holding clips of the sedimentation rack and adjust the blood level to the 0-mark. The sedimentation rate can be taken after 1 hour.The ESR Analyser is designed for the fully automated determination of the blood sedimentation rate (according to Westergren) of up to 48 samples at the

12 same time and independently of each othe
same time and independently of each other.For use with ESR systems KABEVETTE S and V as well as Sarstedt S-Sedivette Item no. Item no. Item no. tation system for the determination of the 3.5 ml, Ø 8.4 mm, L = 130 mm 11 G for the automatic platelet count in case of anticoagulant-induced pseudothrombocytopeniaAnticoagulant: Mg Fill. volume: 3.5 mlNo platelet aggregation G for blood sugar determination during pregnancyGlycolysis inhibitor: Citrate/sodium fluorideFill. volume: 3.5 ml/1.6 mlFill the blood collection tube completely to the mark. After blood collection mix sample very well. Because of the dilution effect due to liquid dosing, the measured glucose value

13 out of the plasma has to be multiplied
out of the plasma has to be multiplied by the factor 1.16. Item no. Item no. 3.5 ml, Ø 13 mm, L = 72 mm4 ml, Ø 13 mm, L = 72 mm 1.8 ml, Ø 13 mm, L = 72 mm Sterile, “Butterfly” principleDEHP-freeMultiple sampling adapter with extension tube AM G 46 K green Art.-Nr. AM G 46 K green security Art.-Nr. Tube lengthAM G 46 BF green 120AM G 46 BF green 240 13 Multiple sampling adapter with safety cannula and Sterile, “Butterfly”DEHP-freeBy placing the adapter on a commercial syringe and attaching a multiple sampling adapter, it is possible to sample blood.Multiple sampling adapter with Adapter for sampling Item no. Description104300AM G 46 Item no.

14 Description104402AE G membrane adapter P
Description104402AE G membrane adapter Packing unit: 100 pcs in dispenser box, 1,000 pcs in boxPacking unit: 100 pcs in dispenser box, 1,000 pcs in boxPacking unit: 50 pcs in dispenser box, 500 pcs in box Tube lengthAM G 46 BF green 120 sec.AM G 46 BF green 240 sec. 14 Tourniquet for one-hand operationwith 6 cups for blood collection tubes, 1 disposal box, 2 cups for implements and 1 cup for swabs.for syringes, cannulas, scalpels, blood pipettes, etc.Material: Polypropylen Item no. Tourniquet Item no. Item no. 090014Disposal box 1.6 ltr.090015Disposal box 2.1 ltr.090016Disposal box 3.1 ltr.Other sizes and designs on request.Other sizes available on request.Materi

15 al: PolypropyleneAutoclavable up to 121Â
al: PolypropyleneAutoclavable up to 121°C Item no. 090002VB 600 x 780600 x 780 mmPacking unit: 1,200 pcs in boxPacking unit: 200 pcs in box 15 N for blood gas analysisAnticoagulant: balanced heparinFill. volume: 2.3 mlindividually sterile packedfor the determination of catecholamines Fill. volume: 7.5 mlfor the determination Catecholamines are stable at room temperature for one day in serum/plasma and for two hours in whole Item no. BG 311 KA 2 individually sterile packed Item no. Catecholamines 792 N 7.57.5 ml, Ø 15 mm, L = 92 mm KABE LABORTECHNIK GmbHD-51588 Nümbrecht-ElsenrothPhone: +49 2293 9132 – 0Fax: +49 2293 9132 – 7030 www.kabe-labortechnik.d

16 e KABE LABORTECHNIK – G, KABE LABOR
e KABE LABORTECHNIK – G, KABE LABORTECHNIK offers a varied range of laboratory materials for the medical laboratory: Venous blood collection systems for human sample collection Venous blood collection systems for veterinary sample collection Capillary blood collection system for a small sample volume (Capillary blood collection range GK)Treated test tubes and collection vessels for blood, urine and faeces analysesUntreated test tubes and reaction vessels, laboratory items made of plasticConsumables for the treatment of pathological/histological samplesWe would be happy to provide you with more information material!Or visit us online at www.kabe-labortechnik.de