PWS 1K20B BR up Power Module Specification INPUT CHARACTERISTICS RATED VOLTAGE CURRENT DC 112 to 129Vdc Battery Cell Capacity 68 Whr DC OUTPUT CHARACTERISTICS Discharging Time x0000 ID: 938123

battery operating load output operating battery output load 1200w x0000 12v current 100 power exclusive 000hours class hot emi

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "1200W 1U Redundant Battery Back" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

PWS - 1K20B - BR 1200W 1U Redundant Battery Back - up Power Module Specification INPUT CHARACTERISTICS RATED VOLTAGE / CURRENT DC 11.2 to 12.9Vdc Battery Cell Capacity 68 Whr DC OUTPUT CHARACTERISTICS Discharging Time: � 35 Sec. at output load 1200W ( 12V/ 100A) � 180 Sec. at output load 500W Output VOLTAGE +12V +12Vsb MAXIMUM CURRENT 100A (1200W) 2.5A REGULATION 12V + - 5% RIPPLE & NOISE 120mV 120mV OUTPUT CONNECTOR Gold Finger GENERAL SPECIFICAIONS REMOTE MANAGEMENT SBS(Smart Battery Spec) 1.1 FRU Data MTBF �100,000hours at 100% load 40 ° C (exclusive of Battery). �300,000hours at 100% load 35 ° C (exclusive of Battery). REDUNDANCY Hot swappable LEAKAGE CURRENT Less than 100uA PROTECTION OCP, OVP, Short Circuit, Over Temperature • Dimension (W x L x H): 106.5 x 245 x 84mm • Maximum Output Power: 1200W REGULATORY SAFETY COMPLIANCE UL60950 - 1 IEC60950 - 1/62133 CCC 5000m BSMI CE /CB FCC EMC EMI Class A ENVIRONMENTAL SPECIFICAIONS AMBIENT TEMPERATURE Operating: 5 ° C to 50 ° C Charge mode: 5 to 50 ° C Discharge mode:5 to 50 ° C Non - Operating: - 40 to 70 ° C OPERATING ALTITUDE Operating: to 3023m Non - Operating: to 10580m RELATIVE HUMIDITY Operating: 20% to 90% (non - condensing) Non - Operating: 5% to 95% (non - condensing) Features and Benefits: • Hot - swappable • SBS 1.1 requirements • Redundant Battery Back - up power module (BBP) • Support MicroBlade . SuperBlade • Real time backup • EMI Class A Disclaimer: Specification is subject to change without prior notice