Coils Design of Commutator amp Brushes Design of Interpoles Magnetic circuit The path of magnetic flux is called magnetic circuit Magnetic circuit of dc machine comprises of yoke poles ID: 1031508

coil field pole winding field coil winding pole armature design area loss current commutation lmt series poles flux shunt

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "D.C Machines Design of Field Poles &..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1. D.C MachinesDesign of Field Poles & Field Coils Design of Commutator & BrushesDesign of Interpoles

2.

3.

4. Magnetic circuit The path of magnetic flux is called magnetic circuitMagnetic circuit of dc machine comprises of yoke , poles, airgap, armature teeth and armature coreFlux produced by field coils emerges from N pole and cross the air gap to enter the armature teeth. Then it flows through armature core and again cross the air gap to enter the S pole .The circuit close through the yoke of a machine.YokeFlux PathPole BodyArmature CoreNSSNMagnetic Circuit of 4-Pole DC Machinehplhpllylc

5. Let Bg – Max. flux density in the core Kg- Gap contraction factor lc – Length of magnetic path in the core l y – Length of magnetic path in the yoke ds - Depth of the slot dc - Depth of core hpl - Height of field pole Dm – Mean diameter of armature When the leakage flux is neglected magnetic circuit of a DC machine consists of following: YokePole and pole shoe Air gap Armature teeth and Armature core Magnetic circuit

6. Total MMF to be developed by each pole is given by the sum of MMF required for the above five sections.MMF for air gap ATg=800000 Bg Kg lgMMF for teeth ATt=att X dsMMF for core ATc=atc X lc/2MMF for pole ATp = atp X hplMMF for yoke ATy= aty X ly/2 att , atc , atp , aty - are determined B-H curveslc = πDm/P = π(D – 2ds – dc)/P ly = πDmy/P = π(D+ 2lg + 2hpl +dy)/P Total AT per pole at no-load and normal voltage =ATg + ATt + ATc + ATp +ATy

7. Design of field windingConsists of poles, pole shoe and field winding.Types:Shunt field windingSeries field windingShunt field winding – have large no. of turns made of thin conductors ,because current carried by them is very low.Series field winding is designed to carry heavy current and so it is made of thick conductors/strips.Field coils are formed, insulated and fixed over the field poles.

8. Design of shunt field winding Involves the determination of the following information regarding the pole and shunt field windingDimensions of the main field pole , Dimensions of the field coil , Current in shunt field winding, Resistance of coil, Dimensions of field conductor, Number of turns in the field coil , Losses in field coil.Dimensions of the main field pole For rectangular field polesCross sectional area, length, width , height of the bodyFor cylindrical poleCross sectional area, diameter, height of the body

9. Let ,ATfl -MMF developed by field winding at full loadQf - Copper loss in each field coil(W)qf - Permissible loss per unit winding surface for normal temperature rise(W/m2 )Sf - Copper space factorρ - Resistivity ( –m)hf - Height of winding(m)df - Depth of winding(m)Design of field systemTentative design of field winding

10. S - Cooling surface of field coil(m2 )Lmt - Length of mean turn of field winding(m)Rf - Resistance of each field coil (ohms)Tf - Number of turns in each field coilAf - Area of each conductor of field winding(m2)If - Current in the field winding (A)δf - Current density in the field winding(A/mm2 )

11. Typical values of various terms used in field design Bp = 1.2 to 1.7 Wb /m2ATfl= (1.1 to 1.25) ATqf = 700 W/m2Sf = 0.4 to 0.75df = 30 to 55mmρ = 2 x 10-8 Ω-mδf = 1.2 to 3.5 A / m m2

12. Important PointsIn a DC machine, each field pole carries one field coil. (No of field coils is equal to the no. of poles)The total amount of flux produced from the main pole is called Main flux or field flux.The amount of flux that strays away (diverts) from the usual path is called leakage flux or loss flux.The amount of flux that links with armature conductors to induced emf – Useful flux or utilised flux.

13. Cooling surface of the field winding, S=2Lmthf -- (1)Permissible copper loss in each field coil, Sqf=2Lmthfqf -- (2)Area of X-section of field coil=hfdf -- (3)Area of copper in each section=Sfhfdf -- (4) i.e, Tfaf=Sfhfdf -- (5)Copper loss in each field coil, Qf=If2 Rf=If2 (TfLmt)/af i.e., Copper loss  f2 (Square of the current density)Design of field system

14. To have temperature rise within the limit, the copper loss should be equal to the permissible loss. Using Eqns. (2) & (6), 2Lmt hf qf =f2 Lmt (Sfhf df ) =>MMF per metre height of field windingDesign of field system

15. Normal values:Permissible loss, qf -700W/m2Copper Space factor, Sf :Small wires: 0.4Large round wires: 0.65Large rectangular conductors: 0.75Depth of the field winding, df :Design of field systemArmature Dia (m)Winding Depth (mm)0.2300.35350.5400.65451.00501.00 and above55

16. Height of field, Total height of the pole, hpl=hf+hs+ height for insulation and curvature of yokewhere, hs - Height of the pole shoe (≈0.1 to 0.2 of the pole height)Design of field system

17. Area of the pole body can be estimated from the knowledge of flux per pole , leakage coefficient and flux density in the pole.Leakage coefficient (Cl) depends on power output of the DC machine. Bp in the pole 1.2 to 1.7 wb/m2 Фp = Cl. ФAp = Фp/BpWhen circular poles are employed, cross section area will be a circleAp = πdp2 /4Design of shunt field winding

18. When rectangular poles employed, length of pole is chosen as 10 to15 mm less than the length of armatureLp=L –(0.001 to 0.015)Net iron length Lpi = 0.9 LpWidth of pole, bp = Ap/LpiHeight of pole body hp = hf + thickness of insulation and clearance Total height of the pole hpl = hp + hsDesign of shunt field winding

19. Field coils are former wound and placed on the poles.They may be of rectangular or circular cross section depends on the type of poles.Dimensions – Lmt, depth, height, diameter.Depth(df) – depends on armature.Height (hf) - depends on surface required for cooling the coil and no. of turns(Tf).hf, Tf – cannot be independently designed.Design of shunt field winding

20. Lmt - Calculated using the dimensions of pole and depth of the coilFor rectangular coilsLmt =2(Lp + bp + 2df) or (Lo +Li)/2Where Lo – length of outer most turn & Li – length of inner most turnFor cylindrical coils Lmt = π(dp +df)No. of turns in field coil: When the ampere turns to be developed by the field coil is known, the turns can be estimatedField ampere turns on load, ATfl= If. Tf Turns in field coil, Tf = ATfl/If Design of shunt field winding

21. Power Loss in the field coil:Power loss in the field coil is copper loss, depends on Resistance and currentHeat is developed in the field coil due to this loss and it is dissipated through the surface of the coilIn field coil design , loss dissipated per unit surface area is specified and from which the required surface area can be estimated.Surface area of field coil – depends on Lmt, depth and height of the coil.Design of shunt field winding

22. Lmt – estimated from dimensions of poleDepth – assumed (depends on diameter of armature)Height – estimated in order to provide required surface area Heat can be dissipated from all the four sides of a coil. i.e, inner , outer, top and bottom surface of the coilInner surface area= Lmt (hf – df)Outer surface area = Lmt (hf + df)Top and bottom surface area = Lmt dfTotal surface area of field coil, S= Lmt (hf – df)+ = Lmt (hf + df)+ Lmt df + Lmt df S= 2Lmt hf +Lmt df = 2Lmt (hf +df) Permissible copper loss, Qf=S.qf [qf -Loss dissipated/ unit area]Design of shunt field winding

23. Substitute S in Qf , Qf = 2Lmt (hf +df).qfActual Cu loss in field coil=If2Rf=Ef2/Rf Substituting Rf=(Lmt Tf)/ af ,Actual Cu loss in field coil=Ef2 .af /(Lmt Tf)Design of shunt field winding

24. Procedure for shunt field designStep1 : determine the dimensions of the pole. Assume a suitable value of leakage coefficient and B = 1.2 to 1.7 T Фp= Cl. Ф Ap = Фp/Bp When circular poles are employed, cross section area will be a circle Ap = πdp2 /4 : dp =Ѵ(4Ap/π) When rectangular poles employed, length of pole is chosen as 10 to15 mm less than the length of armature Lp=L –(0.001 to 0.015) Net iron length Lpi = 0.9 Lp Width of pole = Ap/Lpi

25. Step 1: Leakage CoefficientOutput (kW)Leakage Coefficient (Cl )501.12 to 1.251001.11 to 1.222001.10 to 1.205001.09 to 1.1810001.08 to 1.16

26. Step 2 : Determine Lmt of field coil Assume suitable depth of field winding For rectangular coils Lmt =2(Lp + bp + 2df) or (Lo +Li)/2For cylindrical coils Lmt = π(dp +df)Step 3: Calculate the voltage across each shunt field coil Ef = (0.8 to 0.85) V/PStep 4 : Calculate cross section area of field conductor af = ρLmt ATfl/EfStep 5:Calculate diameter of field conductor dfc =Ѵ(4af/π) Diameter including thickness dfci = dfc + insulation thickness Copper space factor Sf = 0.75(dfc/dfci)2 Procedure for shunt field designArmature Dia (m)Winding Depth (mm)0.2300.35350.5400.65451.00501.00 and above55

27. Step 6 : Determine no. of turns (Tf) and height of coil (hf) They can be determined by solving the following two equations 2Lmtqf (hf + df) = Ef2 af/ρLmt Tf Tf.af = Sf.hf.dfStep 7 : Calculate Rf and If : Rf = Tf. ρLmt /af If = Ef/RfStep 8 : Check for δf δf = If / af δf – not to exceed 3.5A/mm2 . If it exceeds then increase af by 5% and then proceed againProcedure for shunt field design

28. Step 9 : Check for desired value of AT ATactual= If.Tf ATdesired- 1.1 to 1.25 times armature MMF at full load When ATactual less than the desired value then increase the depth of field winding by 5% and proceed again.Procedure for shunt field design

29. Step 10: Check for temp rise: (Class of Insulation) Actual copper loss = If2 Rf Surface area = S = 2Lmt (hf + df) Cooling coefficient C = (0.14 to 0.16)/(1 + 0.1 Va) m = Actual copper loss X (C/S)If temperature rise exceeds the limit , then increase the depth of field winding by 5% and proceed again.

30. Design of Series Field Winding In compound machines, each pole carries a shunt field coil and a series field coil. (appro. 80% of the height – shunt field coil and 20 % by series field coil)Design of shunt field coil for compound machine is same – Already discussed.The series field coil is provided to compensate for the reduction in field mmf due to armature reaction. The ampere turns to be developed by the series field will be 15 to 25% of full load armature ampere turns.

31. In case of series machines, each pole carries a series field coil and all the field coils are connected in series to form series field winding.The ampere turns to be developed by the series field will be 1.15 to 1.25 times the full load armature ampere turns.

32. Design of Series Field Winding Step 1: Estimate the AT to be developed by series field coil, AT /pole = (Iz . (Z/2))/P For compound m/c, ATse = (0.15 to .25) (Iz . Z)/2P For series m/c, ATse = (1.15 to 1.25) (Iz . Z)/2PStep 2: Calculate the no. of turns in the series field coil, Tse = ATse/Ise (Corrected to an integer)(Ia = Ise ---Full load)Step 3: Determine cross sectional area of series field conductor, ase = Ise /δse Normally, δse - 2 to 2.3 A /mm2

33. Step 4 : Estimate the dimension of the field coil Conductor area of field coil = Tse.ase Also Conductor area of field coil = Sfse.hse.dse When circular conductors are used Sfse = 0.6 to 0.7For rectangular conductors, Sfse – depends on thickness and type of insulation On equating above two expressions, Tse.ase = Sfse.hse.dse hse= (Tse.ase )/(Sfse.dse) In case of compound machine, the total height of pole required to accommodate field winding will be sum of the height of shunt field coil and series field coil. Design of Series Field Winding

34. Step 5: Estimate the resistance of series field coil.Resistance of series field coil = ρLmtse Tse ase where Lmtse = Length of mean turn of series field coil The length of mean turn of series field coil can be estimated from the dimensions of the pole.Length of mean turn of series field coil = Lmtse = 2 (Lp +bp + 2dse)

35. Design of commutator and brushes Commutator and brush arrangement are used to convert the bidirectional current to unidirectional current Brushes are located at the magnetic neutral axis (mid way between two adjacent poles)When a armature conductor pass through the magnetic neutral axis, the current in the conductor reverse from the direction to the other. Since the brushes are mounted on magnetic neutral axis, the coil undergoing current reversal is short circuited by carbon brush.  

36. During this short circuit period, the current must be reduced from its original value to zero and then built up to an equal value in the opposite direction. This process is called commutation and the time during which the current reversal takes place is called the time of commutation. The phenomenon of commutation is affected by resistance of the brush , reactance emf induced by leakage flux, emf induced by armature flux.

37. Classification of commutation processResistance commutation Retarded commutation Accelerated commutationSinusoidal commutation When the reactance and rotational emfs are eliminated by the compoles, the commutation is assisted only by the resistance of the brush - Resistance commutation. By employing high resistance carbon brushes, a straight line or linear resistance commutation can be achieved. Design of Commutator and brushes

38. When the brushes are placed at geometrical neutral axis, a reactance voltage and rotational emf are induced in the coil under going commutation. This is due to the shift in magnetic neutral axis during load conditions. These voltages delays the process of current reversal and this type of commutation is called delayed commutation. In this case the commutation is completed before the current can reach its final value and so the current has to jump through the air in the form of a spark at the trailing edge of brush. When the brushes are slightly shifted from magnetic neutral axis in the direction of rotation, the emf induced in the coil undergoing commutation will accelerate the process of current reversal. This type of commutation is called accelerated commutation. This type of commutation may give rise to burning of brushes at the leading edge.

39. When the process of current reversal is delayed at the leading edge and accelerated at the trailing edge, the commutation is called sinusoidal commutation.Commutator is of cylindrical in shape and placed at one end of the armature Consists of number of copper bars or segments separated from one another by a suitable insulating material of thickness of 0.5 to 1mmNumber of commutator segments = no. of coils in the armatureMaterials used : Commutator segments: Hard Drawn Copper or Aluminum Copper Insulation :Mica, Resin Bonded AsbestosBrushes :Natural Graphite, Hard Carbon , Electro Graphite, Metal Graphite

40. Design formulae No. of commutator segments, C = ½ u.Sa where, u – coils sides/slot (always even no) Sa – no. of armature slotsMinimum no. of segments = Ep/15Commutator segment pitch = βc = πDc/C where, Commutator Diameter Dc – 60% to 80% of diameter of armature βc ≥ 4mmThe commutator diameter is also chosen such that the commutator peripheral speed is limited to 15 m/s to 30 m/s. Thickness of brush is selected such that it covers 1 to 3 commutator segments.Current carried by each brush Ib= 2Ia/P for lap winding Ib= Ia  for wave windingTotal brush contact area/spindle Ab= Ib/δbNumber of brush locations are decided by the type of winding Lap winding: No of brush location = no. of poles Wave winding : No of brush location =2Design of Commutator and brushes

41. Area of each individual brush should be chosen such that , it does not carry more than 70A Let , ab – Contact area of each brush nb – Number of brushes / spindle  Contact area of brushes in a spindle, Ab = nb. ab also ab = wb.tb Ab = nb. wb.tb Usually, tb = (1 to 3) βc wb = Ab/ (nb. tb) = ab/tbLc – depends on space required for mounting the brushes and to dissipate the heat generated by commutator losses Lc = nb(wb + Cb) + C1 + C2 where, Cb - Clearance between brushes (5mm) C1 - Clearance allowed for staggering of brushes (10mm, 30mm) C2 – Clearance for allowing end play (10 to 25 mm)Design of Commutator and brushes

42. Losses : Brush contact losses: depends on material, condition, quality of commutationBrush friction losses Brush friction loss Pbf = μ pb AB.Vc μ – Coefficient of friction pb-Brush contact pressure on commutator (N/m2) AB - Total contact area of all brushes (m2) AB =P Ab (for lap winding) = 2 Ab (for wave winding) Vc – Peripheral speed of commutator (m/s)Design of Commutator and brushes

43. Design of Inter polesInter poles are used for reduced the effect of ‘ARMATURE REACTION’

44. Armature Reaction- Armature Reaction is the effect of “Armature field” on the “Main Field”.Armature field is the field which is produced by the armature conductors due to current flowing through them. Main field is the field which is produced by the poles which is necessary for the operation.

45. NSDirection of rotationCurrent going insideCurrent coming outsideMain FieldArmature Field

46. Magnetic flux density increases over one half of the core and decreases over the other half. The flux wave is distorted and there is a shift in the position of M.N.A. It causes the commutation problem. Effects Of Armature Reaction

47. As the compensating windings are too costly, inter-poles are used to neutralize the Cross-magnetizing effect of armature reaction. These are small poles fixed to the yoke and spaced in between the main poles.Inter-poles:

48. The two function of interpoles :(i) As their polarity is the same as that of the main pole ahead, they induce an emf in the coil (under commutation) which helps the reversal of current. The emf induced by the interpoles is known as commutating or reversing emf. The commutating emf neutralizes the reactance emf thereby making commutation sparkless. With interpoles, sparkles commutation can be obtained up to 20 to 30% overload with fixed brush position. In fact, interpoles raise sparking limit of a machine to almost the same value as heating limit. Hence, for a given output, an interpole machine can be made smaller and, therefore, cheaper than a non-interpolar machine. As interpoles carry armature current, their commutating emf is proportional to the armature current. This ensures automatic neutralization of reactance voltage which is also due to armature current.

49. (ii) Another function of the interpoles is to neutralize the cross-magnetising effect of armature reaction. Hence, brushes are not to be shifted from the original position. OF as, represents the mmf due to main poles. OA represents the crossmagnetising mmf due to armature. BC which represents mmf due to interpoles, is obviously in opposition to OA, hence they cancel each other out. This cancellation of crossmagnetisation is automatic and for all loads because both are produced by the same armature current.

50. NNSSNNSSD.C. GeneratorMain PoleInter-Pole

51. NNSSNNSSD.C. MotorMain PoleInter-Pole

52. NSNSMain FieldField by inter polesArmature FieldMain FieldField by inter poles

53. Design of Interpoles Interpoles: Small poles placed between main polesMaterials Used: Cast steel (or) Punched from sheet steel without pole shoesPurposes:To neutralize cross magnetizing armature MMF To produce flux density required to generate rotational voltage in the coil undergoing commutation to cancel the reactance voltage.Since both effects related to armature current, interpole winding should be connected in series with armature winding Average reactance voltage of coil by Pitchelmayer’s Equation is, Erav = 2Tc ac Va.L .λ Inductance of a coil in armature =2Tc2 .L .λ

54. Normally, Length of interpole = length of main pole Flux density under interpole, Bgi = ac. λ .(L/Lip) where, Lip- length of interpole In general, Bgi = 2 Iz. Zs. (L/Lip). (1/Va.Tc).λ MMF required to establish Bgi = 800000Bgi.Kgi.lgi Design of Interpoles

55. Losses and efficiency : Iron Loss - i)Eddy current loss ii) Hysteresis loss Rotational losses - Windage and friction lossesVariable or copper lossCondition for maximum efficiency : Constant Loss= Variable Loss Design of Interpoles