Peripherals for Industrial Au Peripherals for Industrial Au

Peripherals for Industrial Au - PDF document

eve
eve . @eve
Follow
342 views
Uploaded On 2021-08-05

Peripherals for Industrial Au - PPT Presentation

tomationDate 7th Feb 2018 Doc No B2000pdf Rev 2Page1of1ANALOG TIMER TADU60MUFEATURESON Delay Interval8 time rangesUniversal Supply VoltageLow CostHigh ReliabilityCompactDIN Rail Base M ID: 857017

240v supply ops min supply 240v min ops voltage time contact sec 60m switch power interval delay terminals tadu

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "Peripherals for Industrial Au" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 Peripherals for Industrial Au tomation
Peripherals for Industrial Au tomation Date: 7 th Feb 2018 Doc No: B2000.pdf Rev. 2 Page 1 of 1 ANALOG TIMER : TADU - 60M - U FEATURES  ON Delay / Interval  8 time ranges  Universal Supply Voltage  Low Cost  High Reliability  Compact  DIN Rail / Base Mounting TIME RANGES 0 – 3 Sec / Min 0 – 10 Sec / Min 0 – 30 Sec / Min 0 – 60 Sec / Min ( switch s electable) ( Refer NOTE below ) OPERATING MODES ON Delay / Interval (switch selectable) INDICATIONS LED Status Indicator : Power ON, Relay ON SUPPLY VOLTAGE SUPPLY VOLTAGE 20 to 240V AC , 47 – 63Hz or 12 to 240V DC POWER CONSUMPTION 2VA Max INRUSH CURRENT Max . 5 A @ 240V AC for 20ms , 500mA @12VDC ISOLATION Supply Terminals – Contacts : 1.5KV, 1min Contact Set1 – Contact Set2 : 1.5KV, 1min OUTPUT SPECIFICATION OUTPUT CONTACT DPDT (2 C/O) CONTACT RATING 5A@230V AC / 24V DC, Resistive ACCURACY Setting : ±5% of Full Scale, Repeat : ±0.5% or 50msec of Full Scale. RESET On interruption of power, Reset time 100msec ENDURANCE POTENTIOMETER MECHANICAL : 1000 Cycles RELAY ME CHANICAL : 10,000,000 ops. Minimum (1800 ops./h r. ) ELECTRICAL : 100,000 ops. Minimum (1200 ops./h r. ) AMBIENT CONDITIONS OPERATING AMBIENT 0~55 o C, 85% RH STORAGE AMBIENT - 20 o C to 85 o C HUMIDITY 95% RH non condensing GENERAL SPECIFICATIO NS TERMINATIONS Screw type, for 2.5mm sq. wire MOUNTING DIN rail / Base Mount WEIGHT 120 gms PROTECTION LEVEL IP40 for housing, IP20 for terminals, Finger Safe Terminals ORDERING INFORMATION TADU – 60M – U DESIGN NO. SUPPLY VOLTAGE TADU - 60M U : 20 to 240V AC , 47 – 63Hz Or 12 to 240V DC NOTE : I f the time setting is altered , it will be effective from next cycle.  ON Switch S ettings Timing Diagram Terminal Connections Dimensions All dimensions in mm ON Delay / Interval, Universal Supply