Farshid Feyzi August 16 2018 Outline Status of cable routing work Recommendation Remaining work 2 F Feyzi 16 August 2018 Reference APA Consortium Meeting August 6 2018 Report on activities at PSL httpsindicofnalgovevent17065 ID: 801558

conduit cables 2018 august cables conduit august 2018 feyzi apa side work routing cable tubes inch orientation leader tube

Share:

Link:

Embed:

Download Presentation from below link

Download The PPT/PDF document "Cable Routing through APA Side Tubes" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

Cable Routing through APA Side Tubes

Farshid Feyzi

August 16, 2018

Slide2

Outline

Status of cable routing work

Recommendation

Remaining work

2

F. Feyzi

16 August, 2018

Reference:

APA Consortium Meeting August 6, 2018

Report on activities at PSL: https://indico.fnal.gov/event/17065/

Slide3

Conduit for Routing CE Cables

A 2.5 inch OD conduit will be installed in each of the side tubes of both top and bottom APAs

It is done at the ITF after the photon detectors are installed

3

F. Feyzi

16 August, 2018

Slide4

Leader Tube

Cables are fitted into a leader tube of 2.25 inch OD with a nose cone

Connector are inserted in the leader tube at appropriate stagger and are protected

Cables have a protective mesh sleeve for the portion that is in the conduit

4

F. Feyzi

16 August, 2018

Slide5

Cable through Conduit

Inserting the cables into a 2.5 inch OD conduit works in the horizontal orientation

Cables have a protective mesh sleeve for the portion that is in the conduit

It was also tested in the vertical orientation and cables go down under their own weight

.

5

F. Feyzi

16 August, 2018

Need a crescent or reel

Slide6

Recommendation and Remaining Work

Recommend that routing CE cables through APA side tubes is adopted as baseline

Remining work (does not hold up decision):

Put holes in the conduit for access to fasteners

Design and build conduit attachments to the APA side tubeDesign the link mechanism between the top and bottom APAs

Mock up head wire boards on APA head tubeInsert conduit thru APA side tubesTest again in the horizontal orientation, this will conclude tests at the Physical Science lab

Ship all items to Ash River for vertical testing

Figure out how to adequately support cables, cables can bear their own weight when suspended the full length