Parthasarathy MD DA DNB MD Acu Dip Diab DCA Dip Software statistics PhD physiology IDRA Supraglottic device the first standard fixtures in airway management ID: 1033864

tube lma drainage mask lma tube mask drainage airway pressure cuff laryngeal ventilation position plma seal tip device epiglottis

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Laryngeal mask airway Dr. S." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1. Laryngeal mask airway Dr. S. Parthasarathy MD., DA., DNB, MD (Acu), Dip. Diab. DCA, Dip. Software statistics- PhD ( physiology), ( IDRA )

2. Supraglottic device – the first standard fixtures in airway management, filling a niche between the face mask and the tracheal tube in terms of both anatomical position and degree of invasiveness. These devices sit outside the trachea but provide a hands-free means of achieving a gas-tight airway.

3. History Archie Brain – Supraglottic approach was less traumatic Gold man mask in his dental anesthesia clinic Nasal mask was possibly similar to laryngeal inlet Connected the tube with the rim Prototype LMA in 1981

4. From the internet for closed academic purpose only

5. 1983 – first published article in BJA 1985 Katz MD popularized the use in US Slowly commercial devices Replaced ETT in the use as such in number of cases Various modifications !!

6. LMA – classic It consists of an oval soft silicone mask that sits over the larynx with an integrated stem that extends through the oral cavity to allow attachment to the anaesthetic circuit or other appropriate equipment. Mask when inflated, fits around the laryngeal inlet and supports it in a position away from the posterior pharyngeal wall

7. Mask like a bowl continues as a stem to end in a 15 mm male connector for a breathing circuit Mask and stem – 30 degrees Inflatable mask – tube, pilot balloon , valve Grilles across the mask for preventing down folding of epiglottis.Silicone rubber – 40 times autoclavable

8. Taken from internet for closed academic purpose only

9. INSERTION TECHNIQUESomething like swallowing Deflate smooth, Fbs, pilot balloonSniffing positionJaw assistant pen hold – index at junctionBlack line centre of upper lip push for hard palate Release pull assistant cuff tip flat against palate --See folding of tip.

10. Continue pushing with left hand Resistance Anterior laryngeal displacement Inflate to desired ml to see LMA slightly coming out

11. When properly placed, the mask rests on the hypopharyngeal floor. The sides face the pyriform fossae, and the upper border of the cuff is behind the tongue base Other techniques Partially inflated Retromolar and turn Lateral in high arched palate Release cricoid pressure if not

12.

13. Seals !! pharyngeal seal. During controlled ventilation efficacy is dependent on factors such as whether the device orifice sits over the larynx and the quality of the device seal with the laryngopharynx esophageal seal Reducing aspiration risk requires a good-quality seal with the hypopharynx and/or oesophagus

14.

15.

16. If the epiglottis has downfolded, moving the LMA up and down without deflating the cuff may help to reposition the epiglottis. Another maneuver is to withdraw for 5 cm and reinsertMy fixing – gauze piece and a plaster as bite block Intubate through LMA if needed Maintain anesthesia

17. Extubate LMA – my option Supraglottic device – hence patient acceptance is better Small dose fentanyl , cut off agents , awake Reverse and totally awake Deflate – remove the LMA – ask the patient to swallow No suction in LMA removal

18. Although careful placement, cuff inflation, and adaptation time improve the seal, leakage often occurs at 20 cm H2O airway pressure with the classic LMA. Obesity, a head-down tilt, abdominal insufflation, airway obstruction, or any other conditions necessitating ventilation with high airway pressures increase the risk of hypoventilation, gastric insufflation, and regurgitation

19. Taken from internet for closed academic purpose only

20. Advantage LMA !! Professional singers Remote locations Resuscitation Endoscopies ESWL

21. Complications injuries have been reported with LMA use, including injuries to the epiglottis, posterior pharyngeal wall, uvula, soft palate, tongue, and tonsilsSore throat Ventilate ? Change of head position ? rare complications include 12th cranial nerve paralysis, unilateral hypoglossal nerve paralysis and transient bilateral vocal cord paralysis

22. If gastric contents are seen in the laryngeal mask, the patient should be placed in the 30° head-down position, the LMA left in situ, anesthesia deepened, and the breathing system disconnected temporarily to allow drainage and suctioning of the airway tube.Intubate if aspirated

23. LMA-Unique The single-use LMA-Unique (disposable laryngeal mask airway, DLMA) is made of polyvinyl chloride and costs less than a reusable LMAtube is stiffer and the cuff is less compliant. It may be helpful to warm the tube before insertion

24. The reinforced (or flexible) LMAThe reinforced (or flexible) LMA (sizes 2-5) is an alternative version of the LMA in which the tube is thinner, narrower and longer and is reinforced with a spiral of steel wire to add flexibility and reduce the risk of kinking; Difficult to insert. can rotate later Tongue bite safety , no in MRI But nasal surgeries , tonsils !!

25. Insertion of an LMA is frequently difficult in patients in whom tracheal intubation is difficult.

26. Proseal LMA ( pLMA) Aspiration is the danger? Can we decrease leak ?

27. Drainage tube with a ring No grille Cuff s- 2Anterior and posterior Reinforced tube - Hence narrower Bite block

28. pLMAGreater depth Technically more demanding insertionThe device may be introduced digitally or with a special introducer. Bougie to drainage tube and esophagus Bougie to larynx – straight to main tubeLaryngoscope or a tongue depressor

29.

30. Position ?? (1) The PLMA may not be inserted sufficiently far, with the consequence that the tip of the drainage tube lies in the pharynx. Positive-pressure ventilation is ineffective because delivered gas passes out the drainage tube. (2) The tip of the PLMA may lie within the glottis, thereby obstructing ventilation and impairing function of the drainage tube. (3) The tip may be folded over and obstruct ventilation and the drainage tube.

31. Gel to proximal portion of drainage tube The drainage tube gel does not move with positive-pressure ventilation or brief firm pressure applied to the sternum. The drainage tube gel does not move when airway pressure is raised to 20 cm H2O. The drainage tube gel moves slightly when brief “bobbing” pressure is applied to the suprasternal notch (the mechanism is pressure on the esophagus).( SS notch test )Catheter inside drain tube

32. Clinical pearls Can we nebulize ??Pregnancy more than 14 weeks ?? Prone position ?? Classic 20 cm Vs 30 cm peak pressure for pLMA Cuff pressure is 60 cm for both Limit of surgical duration – 2 hours but with proseal 12 hours reported

33. Supreme LMA . Similar to the pLMA, sLMA has an improved cuff design that produces higher airway leak pressures, drainage tube that allows for gastric access,integrated bite block Fixation tab to insert and to find size

34. Summary LMA – history Types Classical insertion tecniques Indications and contraindications Merits and demerits Supreme pLMA Thank you all Other SGD in next classes