ROLACHEM Digital Controller                    PN 554236      21920 ROLACHEM Digital Controller                    PN 554236      21920

ROLACHEM Digital Controller PN 554236 21920 - PDF document

hadly
hadly . @hadly
Follow
342 views
Uploaded On 2021-08-19

ROLACHEM Digital Controller PN 554236 21920 - PPT Presentation

MODEFLOW SWITCHpH OUTPUTFEEDSETLEVELCALIBPOWERALERTAUTO FLOW IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ROLACHEM Digital Controller PN 5 ID: 866953

feed controller chem mode controller feed mode chem rola button time flow chemical alert digital set page 2018 554236

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "ROLACHEM Digital Controller ..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 ROLA-CHEM Digital Controller
ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 1 of 16 MODEFLOW SWITCH pH OUTPUTFEEDSETLEVELCALIBPOWERALERT AUTO FLOW IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 2 of 16 pment, basic safety precautions should always be followed, including: permit children to use they are closely supervised at all times Risk of electric shock. Connect only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI). Contact qualified electrician if you cannotacle is protected by a GFCI and that your installation including grounding of water system components. Do not bury electric cords. Loca lawn mowers, hedge trimmers, and other equipment. Replace damaged cords immediately. Do not use extension cords. Risk of Chemical Overdose/Exposure. Removing power from circulating pump must also remove power from the control

2 ler. d outlet controlled by the circulat
ler. d outlet controlled by the circulating pump circuit. pinching/chemical exposure. Remove power sources or lockout circuit prionance on controller. Risk of Chemical Overdose/Exposure Use a device such as a flow swthe controller in the event of matically dispense chemicals into a circulating Risk of Chemical Exposure. Risk of Chemical Overdose/Exposure. Minimize amount of chemical on site that is available to dispense. Size the feeder and container to pool/spa capacity. all bodies of water. Risk of Chemical Exposure Do not shut down circulation and control system immediately after using pool, spa or hot tub. Systems must operate until water chemistry is stable. Systems must be restarted before water chemistry is out of NSPI recommended ranges or water chemistry must be manually corrected. Wireless communication equipment or other electrical devices operated in close proximity may cause inadvertent actuation of chemical feed pumps. ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 3 of

3 16 1. Safety Instructions
16 1. Safety Instructions 2 2. Quick Start Reference 4 3. Description and Specifications 3.1 General Description 5 3.2 Specifications 6 3.3 Description of controls 6 4. Installation 4.1 Locating the controller 8 4.2 Mechanical installation 8 4.3 Power panel access 8 4.3.1 Fuses 9 4.3.2 Flow Switch 9 4.3.3 Acid/Base Feed 9 4.3.4 Globe Flowcell 9 5. Operation 5.1 Startup 10 5.2 pH settings 10 5.3 pH Calibration 10 5.4 Operating Mode 11 Factory Default 11 6. Troubleshooting 12 7. Warranty 14 8. Appendix 8.1 Water chemistry ranges-NSPI 15 Typical system installations 16 ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 4 of 16 ctions and appropriate manual nd operation instructions. Do NOT add chemicals to feeders until all startup operations are completed. Manually adjust and balance pool/spa to acceptable levels

4 and verify using DPD test used to maint
and verify using DPD test used to maintain chem acceptable chemical ranges. Press the MODE button to turn the unit To turn the controller off press the MODE the MODE button until display reads “OFF”. To Operate: Press and release the MODE button until the “AUTO” light is lit. 0.6 second feed with a 5-minute delay the SET LEVEL button until the desired set point is reached. e FEED TIME button until the de 5 minute delays). - High Alert: press and hold the MODE button then press SET LEVEL button (red pH alert LED will come one), releas decrease the pH High Alert. Press MODE button to continue. - Low Alert: press and hold the MODE button then press SET LEVEL button (red pH alert LED will come one), releas: See the appropriate manual sections for: Calibrating the pH se Changing function (acid/base chemee section 4.3.3 ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 5 of 16 The controller is a microprocessor-based chemical automation system which continuously moni

5 tors and The pH is displayed using sun-b
tors and The pH is displayed using sun-bright light emitting diodemonitored and displayed on the controller’designed to be user friendly. One MODEoperator to easily set parameters. The pH display range is 6.0 to 8.4 with a adjustable from 7.0 to 8.0 with a factory default set point of 7.4. Durifeed lamp will flash when chemicals are being fed and illuminate continuously during the feed delay portion of the feed cycle. The Alert lamp will illuminate when the pH reading its for more than 10 minutes and prevent the feeding of pH chemicals. The feed cycle is a timed based ‘feed then delay’ system. The controller has a series of well as a Continuous feed ). A feed cycle consists second feed time followed by a five-minute delay would have a 5½ minute feed cycle. The chemical feeder dispenses chemical only portion of the cycle and then waits for a delay period to allow swimming pool or spa. Consecutive Feed Alert occurs after 120 minutes ‘Continuous’ feed mode. Feeders will be disabled and digital display will flash (requiring reset). The controller incorpo

6 rates an in which all factory default or
rates an in which all factory default ored. The internal memory is not affected by power interruption and requires no backup battery. handling 5 amps at 120 Volt AC. The relay output is fused and transient protected. An internal terminal strip is provided for field wiring of the controller. The internal step-down transformer has a class-two energy limiting rating to provide for electrical safety. When automating any body of water, it is desired levels in a relatively short period of time. Generally, automating an existing body accordingly. If feeder is unable to keep up with demand in a short period of time, automation becomes ineffective. ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 6 of 16 Display Range: pH 6.0 to 8.4 Set Level Range: pH 7.0 to 8.0 Factory default: pH 7.4 wire grounded power cord. 120 Volts AC, 50/60 HZ, 5 amps (fused) Two 3-wire grounded power receptacles for hardwire applications included Displays: pH reading -red digital

7 LED Flow/Power indicator
LED Flow/Power indicator -green LED Auto (operating mode) indicator -red LED -red LE -green LED continuously duringcycle. OperatingTemperature + pH feed/delay time + Alert (high & low) + Acid/base feed + Calibratio + Flow switch input + Fused outputs Description of Controls The controller has two modes of operation: ON/OFF/Set mode AUTO mode – normaTo move from one mode to another simply press the MODE button. To turn the controller “ON” press the MODE button. To turn the controller “OFF”veral seconds until the pH display reads “OFF”. Release the MODE button and the controller tuy goes blank. ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 7 of 16 Note: Turning the controller “OFF” using controller functions, but doesthe controller. The FLOW lamp is both the power light and a flow inused. When FLOW light is on Set level button:level. To change the set level, press th

8 e SET LEVEL buttreached. Feed time: The
e SET LEVEL buttreached. Feed time: The feed times are displayed in seconds. Each feed cycle includes a five (5) minute delay time. Pressing the FEED TIME button allows the user to select available sired feed time is reached. To set the controller in Continuous feed, release the button when the display reads “con”. Continuous feed runs feeder continuously; consecutive feed alert limit is reached or (3) until High/Low Alert limit is reached. See 3.1 General Description for Consecutive Feed Alert details. pH calibrate: This button allows calibration of the pH sens tested with a test kit. Press the pH CALI should always be taken from the flow cell or container in which the pH sensor is located. The pH calibration allows the adjustment of +/- 1 Consecutive Feed Alert Limit‘Continuous” feed mode or 30 cycles in timed feed mode. See appendix for setting Consecutive Feed Alert Limit. This is normal operation mode. The controller operates the feeder ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 8 of

9 16 Install the chemical pump/ feed syst
16 Install the chemical pump/ feed systems as shown in manuals Before installing the controller, surface within eight feet of the feeder, at leasand within six feet of the GFCI power source. Never mount a controller above or near an acid tank. Never mount a controller in a location accessible to the public. Install the controller in an area protected from natural elements (sun, rain, freezing, etc.). See appendix for typical feed system schematics. Once the site is selected, obtain screws or anchors to securely mount the controller on the wall or a panel. Screw slots are provided in the controller enclosure. Access to flow switch wires, acid/base changes and terminals is located on the back ofh the back of the enclosure.from wall/panel, remove four screws holding enclosure panel to enclosure body. JUMPER ACID FEEDBASE FEED FLOW SWITCH JUMPER FLOW SWITCH LEADSFLOW SWITCH TERMINAL FUSE HOLDERTERMINAL STRIP ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 9 of 16 Fuses protect the controller fro

10 m defectiveenclosure. The fuse holders a
m defectiveenclosure. The fuse holders are shipped wiacement fuses are 5mm The controller has a flow switch terminal shipmust either have the jumper or a flow switch installed.controller also indicates the controller is connted controller requires the use ofa flow switch, remove the jumper and attachretained to assist in troubleshooting. lp keep the flowcell (including probes) and flow switch free from debris (see Globe Flowcell Operating Manual). Debris may obstruct flow switch and prevent the switch from functioning. The controller is shipped with a jumper used to select acid or base chemical. The jumper gure in Section 4.3 power panel access for when the pH reading is above the pH set point. (see Globe Flowcell Operating Manual)Connect the Globe Flowcell grounding stud to ground in order to prevent erroneous readings and to prevent ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 10 of 16 ll startup operations are completed. Using a and balance the water chemistry to acceptable ranges. Auto

11 mation should be used to maintain chemic
mation should be used to maintain chemical levels, not to balance a pool that is out he controller in the OFF mode, turn the filter pump on and ing a flow switch is always recommended. Press and release the controller MODE button until the AUTO light is off. Then select the 4.3.3 for jumper setting detail. To verify thatlevel below the pH indicated on the display. The feed lamp shoulevel above the pH indicated on the displatest method to determine pH value of sample, unless using presPress and release the controller MODE button until the AUTO light is off. Then use pH to match known pH value of 24 hours for the sensors to acclimate to the system so recalibrate 24 hours after the calibration should be checked every four to six weeks. often then probe may need cleaning or replacement. ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 11 of 16 Press the MODE button until AUTO is lighted. This is the operatThe controller must be in intain the desired parameters. Note: When using the RC554P or 5542

12 00 controller with ROLA-CHEM pump, the p
00 controller with ROLA-CHEM pump, the pump Note: the ORP reading is highly dependent on both the pH and the cyanuric acid levels. Both of these variables must be kept within acceptable ranges to maintain an acceptable relationship between Note: Low feed rates can cause the feeder to lag or feeding to be extended. A high feed rate chemical being added. during the delay time of the feed cycle. If over feeding is occurring, consider using a shorter feed cycle. When pH alert lamp is on indicating that pH is below or above the alert settings the tory default The controller can be reset to the default factory settings by using the steps below: A. Press MODE to turn AUTO light off. Release the MODE button. Only the flow light should be on. B. Simultaneously depress and hold SET LEVEL and pH CALIB buttons. While they are depressed,C. Release the buttons. D. The controller is now in test mode. Testminutes to 5 seconds to simplify diagnostics. E. Turn the controller Off F. Turn the controller On toely important since this puts the controller back in ROL

13 A-CHEM Digital Controller
A-CHEM Digital Controller PN 554236 2/19/2018 Page: 12 of 16 6. Troubleshooting Check flow switch in Globe Feeder power and time switches muCheck feeder by using alternate power source. * Factory setting for feed time is 0.6 sec on with 5 minute delay. Feeders may require longer feed time. * Chemical reading has met Set Level. 6.2 Displayed chemical level do* Sensor (probe) is not * Sensor (probe) needs cleaning. (see Globe Flowcell Operating Manual) * Sensor (probe) needs replacing. * Connect Globe Flowcell ground stud to ground. (see Globe Flowcell Operating Manual) 6.3 Set-points not being reached or maintained * Factory setting for feed time is 0.6 sec on with 5 minute delafeed time. If time is too short, set-points will not be maintained. If time is too long, er output, chemical concentration and chemical needs. * Controllers are designed to maintain set-points. Do not expect controllers to make major adjustments—major changes should be done manually. Automation using controllers may req

14 uire larger feeder or more concentrated
uire larger feeder or more concentrated chemicals than system that uses continuo* Factory setting for Consecutive Feed Alert Limit is 30 cyclesminutes for continuous feed modemet within this limit then longer feed time may be required. ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 13 of 16 6.4 Error Code Displayed procedure. A. Unplug power from controller. B. Simultaneously depress and hold SET LEVEL and pH CALIB buttons. While they are depressed, plug in controller power cord. C. Release the buttons. Test mode reduces thfrom 5 minutes to 5 seconds to simplify diagnostics.. until display reads “oFF”. Only the flow light should be on. the controller On and return to operating mode. ely important because this If the error code continues to appear contact ROLA-CHEM service personnel. 6.5 Digital Display numbers flashing * Consecutive Feed Alert Limit has been reached. See Consecutive Feed Alert Limit details in section 3.1 General Description. * Adjust feed time as needed. * High/L

15 ow alert limit has been reached. * Adjus
ow alert limit has been reached. * Adjust feed time or alert settings as needed. * See Globe Flowcell operating manual. ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 14 of 16 7. Warranty and Service Limited Warranty: ROLA-CHEM warrants the original purchaser thdefects in material and workmanship from the year. CHEM’s option) at no charge when return proof of purchase receipt. This warranty does not apply to any product damage caused by improper use, accident, misuse, improper line voltage, fire, flood, lightning, earthquake, other acts of nature, or if product was altered or opened by anyoneCHEM personnel. Heavy duty probes are warranted from the datese for one (1) year. ROLA-CHEM, under no circumstances, shall directly or indirectly caused by this unit. Please observe all rules and regulations required by state and local regulations, bucodes, OSHA, etc. Service Procedure: For operation assistance in the United States please call: (800) 549-4473, Monday thro Central Time or email: er and s

16 erial number available. ROLA-CHEM has sp
erial number available. ROLA-CHEM has specialized knowledge and and diagnose your product. Contact our service personnel as noted above for assistance. If you are directed to ship the product to ROLA-CHEM and given an RGA#, please note RGA# on the package and ship freight pre-paid to: ROLA-CHEM CORPORATION ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 15 of 16 8. Appendix 8.1 Water Chemistry Ranges ance with suggested NSPI Standards for swimming pools.) pH: s where it naturally occurs in the local professional in your area. Cyanuric Acid: 0-50 ppm. Maintain at 30 ppm or leTDS (Total Dissolved Solids): Calcium Hardness: Free Chlorine: 1.0-3.0 ppm (� 700 mV ORP) *20-30 ppm of cyanuric acid provides approx. 95% of the shielding effect for chlorine.**When using tri-chlor, recommended alkalinity is 95-125 ppm. ROLA-CHEM Digital Controller PN 554236 2/19/2018 Page: 16 of 16 8.2 Typical System Installations