/
Peripherals for Industrial Automation Peripherals for Industrial Automation

Peripherals for Industrial Automation - PDF document

hanah
hanah . @hanah
Follow
360 views
Uploaded On 2021-06-17

Peripherals for Industrial Automation - PPT Presentation

Date 7 th Feb 2018 Doc No B1000pdf Rev 2 Page 1 of 1 ANALOG TIMER TADU 60M All dimensions in mm FEATUR ES ON Delay Interval DIP switches on front 8 time ran ID: 844272

sec supply ops min supply sec min ops time terminals 60m switch voltage power interval delay 24v 230v tadu

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "Peripherals for Industrial Automation" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 Peripherals for Industrial Automation
Peripherals for Industrial Automation Date: 7 th Feb 2018 Doc No: B1000.pdf Rev. 2 Page 1 of 1 ANALOG TIMER : TADU - 60M All dimensions in mm FEATUR ES  ON Delay / Interval  DIP switches on front  8 time ranges  Dual Supply Voltage  Low Cost  High Reliability  Compact  DIN Rail / Base Mounting TIME RANGES Switch Settings 0 – 3 Sec / Min 0 – 10 Sec / Min 0 – 30 Sec / Min 0 – 60 Sec / Min (switch s electable) ( Refer NOTE below ) OPERATING MODES ON Delay / Interval (switch s electable) INDICATIONS LED Status Indicator : Power ON, Relay ON SUPPLY VOLTAGE SUPPLY VOLT AGE 230V AC or 24V AC/DC ± 15% , 47 – 63 Hz 110 V AC or 24V AC/DC ± 15% , 47 – 63 Hz (Refer ordering information below) POWER CONSUMPTION 6VA MAX INRUSH CURRENT Maximum 3.2A , 20ms ISOLATION Supply Terminals – Contact : 1.5 KV, 1min. OUT PUT SPECIFICATION OUTPUT CONTACT SPDT (1 C/O) CONTACT RATING 5A@230V AC / 24V DC, Resistive ACCURACY Setting: ± 5% of Full Scale, Repeat: ± 0.5% or 50msec of Full Scale. RESET On interruption of power, Reset time 100msec ENDURANCE POTENTIOMETER MECHANICAL : 1000 Cycles RELAY M ECHANICAL : 10,000,000 ops. Minimum (1800 ops./h) ELECTRICAL : 100,000 ops. Minimum (1200 ops./h) AMBIENT CONDITIONS OPERATING AMBIENT 0~55 o C, 85% RH STORAGE AMBIENT - 20 o C to 85 o C HUMIDITY 95% RH n on condensing GENERAL SPECIFICATIONS TERMINATIONS Screw type, for 2.5mm sq. wire MOUNTING DIN rail / Base Mount WEIGHT 100 gms PROTECTION LEVEL IP40 for housing, IP20 for terminals, Finger Safe Terminals ORDERING INFORMATION TADU – 60M – W DESIGN NO. SUPPLY VOLTAGE TADU - 60M W : 230VAC or 24VAC/DC X : 110VAC or 24VAC/DC NOTE : I f the time setting is altered , it will be effective from next cycle. Timing Diagram Dimensions  ON ON Delay / Interval Terminal Connections * Apply either 2 4V AC/DC or 230V AC supply as shown