FBE04 BUILDING CONSTRUCTION AND MATERIALS Wong Chear Ching chearchinggmailcom Stairs S T AIRS 1 Why do we need to learn about Stairs Interconnectivity of space Accessibility Circulation ID: 762696

staircases stairs handrail concrete stairs staircases concrete handrail width design risers landing barrier height staircase considerations steel flight tread

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "FBE04 BUILDING CONSTRUCTION AND MATERIAL..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

FBE04 BUILDING CONSTRUCTION AND MATERIALS Wong Chear Chingchearching@gmail.com Stairs

S TAIRS1

Why do we need to learn about Stairs Interconnectivity of space Accessibility Circulation / Flow Fire escapeFunctional requirementsDesign considerationsTypes of Stairs

OBJECTIVES 4 State the functional requirements of stairs Define the various terminology related to stairs Identify the different forms of staircase construction and list the design considerations of staircases.Describe the characteristics of different staircases and compare their advantages and disadvantages.

Introduction Staircases provide a mean of access between different floor levels within a building 5

Functions of Stairs6 To allow normal access from floor to floor To allow escape from upper floors in the event of fire

Strength & stabilityFire Resistance Sound InsulationAesthetics Functional Requirement

CLASSIFICATION Shap e Materials Quar t er turn Dog leg Spiral Straight Timber f l ight Co n crete Steel Brick 8

Configuration of Staircases9

Configuration of Staircases10

Straight Flight Stairs 11

Quarter Turn Stairs 12

Half Turn (dog-leg) Staircases 13

Spiral Stairs 14

CLASSIFICATION Shap e Materials Quar t er turn Dog leg Spiral Straight Timber f l ight Co n crete Steel Brick 15

Timber Stairs 16

Concrete Stairs 17

Brick Stairs 18

Metal Stairs 19

Composite Stairs combination of at least two different materials made of concrete or steel composite stairs are steel support with concrete or timber treads 20

Components of A StaircaseTreads and Risers StringsClosed String Open or Cut String Landings Balustrades Open balustradeClosed balustrade21

Open Strings Cut to the profile of the treads and risers to support them 22

Closed Strings Encloses the treads and risers which it supports and top edge protrude 50- 63mm above nosing23

L andings 24

24 Handrail,Baluster & Newel Post Baluster Handrail Newel post

Closed Balustrades Consists of framed or unframed panels acting as baluster to support the handrail 26

Open Balustrades Vertical balusters spaced at certain interval to support the handrail 27

Handrails & Balustrade s 28

Stair Terminology

Stair Terminology

Basic Design ConsiderationsThe risers and treads within each flight of stairs shall be of uniform height and size. The height of a riser shall not be more than 175 mm . The width of a tread shall not be less than 275 mm . The width of a tread of any staircase in any residential unit shall not be less than 225mm. The width of a tread of any staircase in any industrial building shall not be less than 250mm. The width of the tread of any tapered step shall be taken as that when measured at a distance of 500mm from the narrower end.TreadRiser31

The pitch of the stair shall be a maximum of 42°. The clearance of headroom should not be less than 2.0 m measured vertically above pitch line. Basic Design Considerations 32

A landing shall be provided at every floorlevel and door opening. Except for spiral staircases, an intermediate landing shall be provided in between floor levels at intervals of not more than 18 risers . The clear width of any landing, measured from the handrail or kerb (whichever protrudes further into the landing) to the wall or external railing of the landing, shall not be less than 900 mm32Basic Design Considerations

Width of Stair & Landing (min 900mm) 34

A handrail shall be provided on at least one side of the flight of staircase The height of the handrail shall be between 750mm and 1000mm above the pitch line. Where there is a vertical drop in level of 1.0 m or more (for a staircase with more than say 5 steps), appropriate measures shall be taken to prevent people from falling from a height. Where a barrier is used to prevent falling from a height, the barrier shall not have any feature that facilitates the climbing of the barrier. The height of a barrier shall not be less than 1.0 m. The height of a barrier at the flight of stairs is measured vertically from the pitch line to the top of the barrier. Basic Design Considerations 35

Handrails shall: have a circular section of 32mm to 50mm in diameter or an equivalent gripping surface; andhave a clear space between the handrail and all wall surface – (i) not less than 40mm; or (ii) at least 60mm where the wall has a rough surface.A recess containing a handrail shall extend at least 450mm35Basic Design Considerations above the top of the rail

For a flight of staircase,In all buildings, except for industrial buildings, any triangular opening or void formed around a tread, riser and the bottom edge of the barrier, the size of any opening or gap shall not be large enough as to permit the passage of a sphere of a diameter of 150mm.In all buildings, except for industrial buildings, the gap size between any two consecutive steps shall not be large enough as to permit the passage of a sphere of a diameter of 100mm; and In industrial buildings, the gap size between any two consecutive steps shall not be large enough as to permit the passage of a sphere of a diameter of 150mm . Basic Design Considerations 37

Number of risers is not to exceed 18 in any flight of steps. Except for spiral, circular or geometric staircases, an intermediate landing shall be provided in between floor levels at intervals of not more than 18 risers. The width of landings should not be less than the width of the stairway.Basic Design Considerations38

Concrete StaircasesMost commonAdvantages good fire resistanceStrong better sound insulation Disadvantages Slow in erection – wet process Proper training required39

Requirements: Concrete Grade 30 or above Minimum concrete cover 20 mm Waist thickness between 100 to 250mm Mild steel or high yield steel bars can be used as reinforcement Handrail to be at least 900 mm above the pitch line40Concrete Staircases

Concrete cover Waist thickness Min 900 mm H a n d - railing Concrete Staircases 41

Finishes Warehouse – natural finishes. Add carborundum dust / rubber strips for slip resistance PVC tiles Rubber tiles Carpet mats 42Concrete Staircases

Concrete Staircases43

Precast Staircases44 Advantages Better quality control Saving in site space Faster construction Installation issimple.DisadvantagesRequires mass production.

Precast Staircases Precast Concrete Treads 45