MULTISPLIT MULTI LIBERTY DC INVERTER MULTISPLIT MULTI LIBERTY DC INVERTER

MULTISPLIT MULTI LIBERTY DC INVERTER - PDF document

madeline
madeline . @madeline
Follow
345 views
Uploaded On 2021-08-19

MULTISPLIT MULTI LIBERTY DC INVERTER - PPT Presentation

18HKEU XHTFU XHFIU XHUCU XHKEU 209539 XHTFU 208538 XHFIU 208538 XHUCU 208538 XWide range of indoor units from wall to cassette 60x60 console and ductedPossibility to connect up to 5 indoor units19MULT ID: 866864

220 refrigerant terminal board refrigerant 220 board terminal side external internal 230v 1510 50hz1 inverterdc efficiency 208 538 class

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "MULTISPLIT MULTI LIBERTY DC INVERTER" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 18 MULTISPLIT MULTI LIBERTY DC INVERTER
18 MULTISPLIT MULTI LIBERTY DC INVERTER HKEU X HTFU X HFIU X HUCU X HKEU 209~539 XHTFU 208~538 XHFIU 208~538 XHUCU 208~538 X Wide range of indoor units, from wall to cassette 60x60, console and ducted.Possibility to connect up to 5 indoor units. 19 MULTISPLIT MULTI LIBERTY DC INVERTER HCKU 408 X2 DUAL HCKU 808 X3 TRIALHCKU 1068 X4 POKER (QHUJ\HIÀFLHQF\YDOXHVUHIHUWRWKHIROORZLQJFRPELQDWLRQV1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825.3 Value measured according to EN14511.Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. ModelHCKU 408 X2HCKU 538 X2HCKU 608 X3HCKU 808 X3HCKU 818 X4HCKU 1068 X4HCKU 1068 X5TypeDC InverterDC InverterDC InverterDC InverterDC InverterDC InverterDC InverterIndoor unit connectable n°2233445Capacity (T=35°C)CoolingkW4.10 (1.54~5.50)5.30 (1.40~6.60)6.16 (1.56~8.93)8.00 (1.38~9.80)8.21 (1.38~11.09)10.55 (1.27~13.80)10.50 (1.30~17.23)Power Input (T=+35° C)CoolingkW1.200 (0.61~1.83)1.570 (0.41~2.09)1.900 (0.53~3.03)2.410 (0.48~3.06)2.470 (0.58~3.75)3.250 (0.55~4.31)3.280 (0.55~5.82)Annual ConsumptionCoolingkWh/a282320386477470707656Energy Efficiency Class SeasonalCooling626/2011AA+A+A+A++AA+Energy Efficiency Class Seasonal IndexCoolingSEER5.15.85.85.86.15.25.6Coefficient of Energy Efficiency RatedCoolingEER3.423.383.243.323.323.253.20Design load (Pdesignc)CoolingkW4.105.306.407.908.2010.5010.50Capacity (T=+7° C)HeatingkW4.60 (1.59~5.70)5.80 (1.30~6.40)6.74 (1.67~9.32)8.85 (1.47~10.50)9.10 (1.59~12.30)11.70 (1.59~14.40)12.30 (1.59~17.74)Power Input (T=+7° C)HeatingkW1.080 (0.45~1.75)1.462 (0.37~1.80)1.750 (0.49~2.80)2.350 (0.46~2.75)2.440 (0.47~3.71)3.100 (0.61~4.23)3.400 (0.61~5.23)Ann

2 ual ConsumptionHeatingkWh/a1540206322473
ual ConsumptionHeatingkWh/a1540206322473021298438323868Energy Efficiency Class Seasonal (average season)Heating626/2011A+AAAAAAEnergy Efficiency Class Seasonal Index HeatingSCOP4.03.83.83.83.83.83.8Coefficient of Energy Efficiency RatedHeatingCOP4.263.973.853.773.733.773.62Design load (Pdesignh)HeatingkW4.405.606.108.208.1010.4010.50T° operational limit (Tol)Heating°C-15-15-15-15-15-15-15Power supplyPh-V-Hz1-220~230V-50HZ1-220~230V-50HZ1-220~230V-50HZ1-220~230V-50HZ1-220~230V-50HZ1-220~230V-50HZ1-220~230V-50HZI.U. ~ O.U.O.U.O.U.O.U.O.U.O.U.O.U.O.U.Input Rated Current (Cooling - Heating)A5.70 - 6.507.00 - 7.408.30 - 7.6010.80 - 10.3011.20 - 11.1014.30 - 14.5016.60 - 15.30Wiring cables i.u./o.u. (without ground)n°3 (internal and external side terminal board)3 (internal and external side terminal board)3 (internal and external side terminal board)3 (internal and external side terminal board)3 (internal and external side terminal board)3 (internal and external side terminal board)3 (internal and external side terminal board)Refrigerant circuitRefrigerant Pipe Liquid/Gas sidemm/inch.[¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ [¡ µ 5HIULJHUDWLQJSLSHVDGDSWHU  D n.1222345TOTAL Piping Lengthm30304545606075MAX length of one refrigerant linem20202525303030Max splitting level difference O.U./I.U. - I.U./ O.U.m10/1510/1510/1510/1510/1510/1510/15Refrigerant Prechargekg1.551.902.102.402.402.703.00MAX Splitting with Refrigerant Precharge (each I.U.)m5555555Additional Refrigerant ChargeLiquid Pipe ø1/4"g/m15151515151515Temperature range cooling°C-15° C ~ +50° CTemperature range heating°C-15° C ~ +24° CSpecificationsOutdoor UnitDimension (WxHxD)mm845x700x320845x700x320845x700x320900x860x315900x860x315990x965x345990x965x345Netkg46485062657880Max noise level 1 m dB(A)60625862616565Max power sound leveldB(A)63636467707068Max air flow /h250025002700350038005500550