CONTROLLERS FOR PLUGINS IDPlus Invensys Proprietary amp Confidential 1 1 1 1 IDPlus Simplicity and flexibility at the service of refrigerator technicians Invensys 000000 Invensys proprietary amp confidential ID: 473258

proprietary invensys confidential amp invensys proprietary amp confidential slide unicard ntc temp idplus manager device 2hp 12vac defrosttime economy

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "ID PLUS" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

ID PLUS

CONTROLLERS FOR PLUGINS:IDPlus

® Invensys Proprietary & Confidential

1

1

1

1Slide2

IDPlus: Simplicity and flexibility at the service of refrigerator

technicians© Invensys 00/00/00

Invensys proprietary & confidentialSlide

2Slide3

IDPlus: general description

© Invensys 00/00/00Invensys proprietary & confidentialSlide

3

5 models cover the complete range of static and ventilated counters Simple and intuitive menu for rapid learning (like the EW) Each model includes 4 preset configurations for quick, sure installation

Rapid resetting to controller's initial configuration Compatibility of NTC, PTC and PT1000 (-50/150°C) sensors simply by

changing a parameter (Danfoss aftermarket) Unicard USB for easy, quick customizing

Documentation in choice of languagesSlide4

IDPlus: additional features

© Invensys 00/00/00Invensys proprietary & confidentialSlide

4

Modbus/Televis selectable by parameterIntegrated HACCP alarms Pressure switch alarm

COH compressor overheating alarmquick blast chilling (deep cooling)Stock management: the small number of models gives

better availability with a lower stock levelSlide5

IDPlus:

models

© Invensys 00/00/00Invensys proprietary & confidential

Slide 5

IDPlus

902 NTC 8A 230Vac

IDP11D0700000

IDPlus

961 NTC 2Hp 230Vac

IDP17D0700000

IDPlus

971 NTC 2Hp

buz

. 230Vac

IDP29DB700000

IDPlus

974 NTC 2Hp 230Vac BUZ

IDP2EDB700000

IDPlus

978 NTC 2Hp 230Vac BUZ

IDP24DB700000

IDPlus

902 NTC 8A 12Vac-dc

IDP11D0300000IDPlus 961 NTC 2Hp 12Vac-dc IDP17D0300000 IDPlus 971 NTC 2Hp bz 12Vac-dc IDP29DB300000IDPlus 974 NTC 2Hp 12Vac BUZ IDP2EDB300000

230V AC

12Vac-dcSlide6

IDPlus: User Interface

© Invensys 00/00/00Invensys proprietary & confidentialSlide 6

/978Slide7

IDPlus902

© Invensys 00/00/00Invensys proprietary & confidentialSlide 7Slide8

IDPlus961

© Invensys 00/00/00Invensys proprietary & confidentialSlide 8Slide9

IDPlus971

© Invensys 00/00/00Invensys proprietary & confidentialSlide 9Slide10

IDPlus974

© Invensys 00/00/00Invensys proprietary & confidentialSlide 10Slide11

IDPlus978

© Invensys 00/00/00Invensys proprietary & confidentialSlide

11

12Vac-dcSlide12

IDPlus902/961: the applications

© Invensys 00/00/00Invensys proprietary & confidentialSlide

12

12

34

coolcool

heat

cool

compressor

compressor

heating elements

compressor

defrost

---

---

defrost

Economy

(D.I.)

Economy

(D.I.)

COH

on Pb3

ID 961LX

IC 902/C

IC 902/H

ID961 beer coolers

Application 4Slide13

IDPlus971: the applications

© Invensys 00/00/00Invensys proprietary & confidentialSlide

13

12

34

coolcool

cool

cool

Time/temp defrost

Time defrost

Time/temp defrost

Time defrost

Heating elements

Heating elements

fans

alarm

---

---

---

buzzer

Economy

(D.I.)

Economy

(D.I.)

Door

(D.I.)

Economy

(D.I.)

ID 971LX

ID 970LX---ID 961/A

Application 3Slide14

IDPlus974: the applications

© Invensys 00/00/00Invensys proprietary & confidentialSlide

14

12

34

coolcool

cool

cool

Time/temp defrost

Time/temp defrost

Time/temp defrost

Time/temp defrost

Heating elements

Heating elements

aux

Reversing

valve

fans

fans

fans

fans

buzzer

buzzer

buzzer

buzzer

Economy

(D.I.)

HACCP (pb3)

Door

(D.I.)Economy (D.I.)

ID 974LXID 974LX HACCP

ID

“light”

ID

hot gas

Application 1Slide15

IDPlus978: the applications

© Invensys 00/00/00Invensys proprietary & confidentialSlide

15

12

34

coolcool

cool

cool

Time/temp defrost

Time/temp defrost

Time/temp defrost

Time/temp defrost

Heating elements

Heating elements

Heating elements

Reversing

valve

fans

fans

fans

fans

alarm

alarm

aux

alarm

Economy

(D.I.)

HACCP (pb3)

Door

(D.I.)Economy

(D.I.)ID975

ID975

ID975

ID975Slide16

IDPlus: customization/lots

© Invensys 00/00/00Invensys proprietary & confidentialSlide

16

Customization of parameter maps by means of:- UNICARD

- DEVICE MANAGEROptions NOT possible:

- Bulk package

- male only and/or male+female removable screw terminals

display colours other than amberSlide17

UNICARD:

general description/model

© Invensys 00/00/00Invensys proprietary & confidential

Slide 17

The UNICARD can be used to upload/download instrument parameters. Its flexibility means the devices can be customized quickly and easily, thereby reducing the number of models needed to meet the requirements of different installations

The UNICARD can be used to power the instrument directly via USB port (vast range of power supplies and adapters available on the market).The UNICARD can also be used with the current IDs and ICs: these products are not and will not be compatible with the Device Manager.

UNICARD USB/TTL CCA0BHT00UU00Slide18

UNICARD: examples of use

© Invensys 00/00/00Invensys proprietary & confidentialSlide

18Slide19

UNICARD: Device Manager

© Invensys 00/00/00Invensys proprietary & confidentialSlide

19

DEVICE MANAGER 100

DMP1000002000

http://www.eliwell.it/supporto

(

Systems Area)

With the Device Manager software, EW plus and ID Plus parameter lists can be read and written in the UNICARD without having to use additional interfaces (e.g. PC interface).

Device Manager is downloadable free of charge from the site

www.eliwell.it

Slide20

UNICARD: Device Manager,

functions© Invensys 00/00/00Invensys proprietary & confidentialSlide

20

Upload parameter map (

instrumentUNICARD)

'Read' for reading parametersChange value/visibility after editing'Write' for writing the edited parameters on the UNICARD

'Save' for saving a file.dax on PC

“Load file” - for reloading a stored file.dax

Download from reset (powered

UNICARD

instrument

)Slide21

© Invensys 00/00/00

Invensys proprietary & confidentialSlide 21

Related Contents


Next Show more