High Precision Decay Data for Medical Isotopes High Precision Decay Data for Medical Isotopes

High Precision Decay Data for Medical Isotopes - PowerPoint Presentation

morton
morton . @morton
Follow
65 views
Uploaded On 2023-10-04

High Precision Decay Data for Medical Isotopes - PPT Presentation

Decay Data and Medical I sotopes Essential for determining Overall dose Specific dose Imaging background Production cross section Over half were last studied gt30 years ago 30 Years ago 12 small detectors ID: 1022167

data decay medical isotopes decay data isotopes medical national cross gammasphere detectors blip measurements high isotope linear precision producer

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "High Precision Decay Data for Medical Is..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1. High Precision Decay Data for Medical Isotopes

2. Decay Data and Medical Isotopes Essential for determining:Overall doseSpecific doseImaging backgroundProduction cross sectionOver half were last studied >30 years ago !!30 Years ago: 1-2 small detectorsPresent: 10-100 detectors

3. Important medical isotopes requiring new measurements of decay data produced at BLIPShipped to world’s largest -ray array Gammasphere (100 HPGe detectors) for high-precision -ray spectroscopy USNDP-BLIP Decay Data CollaborationBrookhaven Linear Isotope Producer (BLIP)

4. Starting point : 82Rb for Cardiac PETD. Le Guludec et al., Eur. J. Nucl. Med. Mol. Imaging 35, 1709 (2008). R.A. Meyer et al., Phys. Rev. C 27, 2217 (1983). 2 Ge(Li) detectors

5. Prior SinglesPreliminary Analysis Very PromisingGate on 2+0+Rb-82 decay

6. What we learned (and where to go)Gammasphere is incredibly powerfulCoincidence efficiency is AMAZINGCould study several isotopes at onceCould simultaneously measure decay schemes AND cross sectionsImagingCardiac ImagingCharged particle cross-section database for medical radioisotope production: diagnostic radioisotopes and monitor reactions - IAEA-TECDOC-1211

7. First results from “dual” experiments100 MeV protons on natural NiWe make a lot and some isotopes have applied usesFor example, Co-55 and Mn-52, both studied 1970’sSingles

8. Gate on 1434-keV935744Coincidences are essentialDecay of Mn-52

9. One last example19681971

10. Prior Gated SpectrumPreliminary Analysis of As-72 DecayExcellent statistics on known transitionsMany new transitions

11. Summary and OutlookInitiated a successful campaign of measurements combining BLIP and Gammasphere capabilitiesNew beta decay measurements will improve ENSDFAlso possibility for cross section measurementsLOTS OF DATA: Anyone interested?

12. CollaboratorsA.A. SonzogniNational Nuclear Data Center, Brookhaven National LaboratoryS.V. Smith, L. MuenchBrookhaven Linear Isotope Producer, Brookhaven National LaboratoryC.D. NesarajaPhysics Division, Oak Ridge National LaboratoryJ.P. Greene, M.P. Carpenter, and S. ZhuPhysics Division, Argonne National LaboratoryC.J. Lister, P. Chowdhury, and K. MoranPhysics Department, University of Massachusetts, Lowell