Optional Setup with Atmospheric Inx0066006Cation  ROHO Cushions Optional Setup with Atmospheric Inx0066006Cation  ROHO Cushions

Optional Setup with Atmospheric Inx0066006Cation ROHO Cushions - PDF document

naomi
naomi . @naomi
Follow
366 views
Uploaded On 2021-06-29

Optional Setup with Atmospheric Inx0066006Cation ROHO Cushions - PPT Presentation

WARNING These instructions should NOT be used with the ROHO Single Compartment Cushion with Sensor ReadyTechnology and Smart Check by ROHO IMPORTANT A clinician who is experienced in seating and po ID: 848957

cushion x0066006c roho ation x0066006c cushion ation roho valve select fig cushions air place hand atmospheric compartment ate seating

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "Optional Setup with Atmospheric Inx00660..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 Optional Setup with Atmospheric In
Optional Setup with Atmospheric In�ation - ROHO Cushions** Use these instuctions ONLY with: ROHO Single Compartment Cushion (HIGH, MID, LOW PROFILE)ROHO QUADTRO Select HIGH PROFILE Cushion ROHO ENHANCER Cushion WARNING: These instructions should NOT be used with the ROHO Single Compartment Cushion with Sensor ReadyTechnology and Smart Check by ROHO. IMPORTANT! A clinician who is experienced in seating and positioning should determine whether atmospheric in�ation is appropriate for the individual's seating needs. For alternate in�ation instructions and additional setup, safety, and care information, refer to the manual provided with the cushion and cover. WARNING:DO NOT place any weight on the cushion during atmospheric in�ation.In�ate the cushion and de�ate to atmospheric pressure.QUADTRO Select Cushion: Push the green knob to unlock the ISOFLO Memory Control before in�ating the cushion. (Fig. 1) 2.Open the in�ation valve. (Fig. 2)3.In�ate with the hand pump until all of the air cells feel �rm. 4.Remove the hand pump. Do not close the in�ation valve. 5.Allow air to escape from the in�ation valve. Suggestion: Listen (or place your hand in front of the in�ation valve) to con�rm that de�ation has stopped.6.Close the in�ation valve. (Fig. 3)Finish setup.Place the cushion on the seating surface, air cells facing up. 2.Place the cover on the cushion. 3.Transfer to the cushion.4.Perform a hand check to con�rm that the cushion has the correct amount of air, as shown below. (Fig. 4) IMPORTANT! Select and ENHANCER Cushions: For cushions that have more than one in�ation valve or more than one compartment: Perform all steps for all valves and compartments. Select and ENHANCER Cushions may require additional positioningand adjustment. Refer to the instructions provided with the cushion.Fig. 1 Unlock LockISOFLO Memory ControlQUADTRO Select Cushions OpenFig. 2 CloseFig. 3 WARNING: ROHO, Inc., 100 North Florida Avenue, Belleville, Illinois 62221-5429 USAU.S.A.: 800-851-3449 · Fax: 888-551-3449 · orders.roho@permobil.com · permobilus.comOutside the U.S.A.: 618-277-9150 · Fax: 618-277-6518 · intlorders.roho@permobil.com This document is for clinician use only.