BA21BA21Effective Copyright 2007  www.o-zgedney.com BA21BA21Effective Copyright 2007  www.o-zgedney.com

BA21BA21Effective Copyright 2007 www.o-zgedney.com - PDF document

patchick
patchick . @patchick
Follow
342 views
Uploaded On 2020-11-19

BA21BA21Effective Copyright 2007 www.o-zgedney.com - PPT Presentation

Hazardous Location Fittings Outlet Boxes Trade Size Catalog Catalog Number NumberMalleable Malleable Iron Iron Cover CoverBody Malleable Malleable Iron Body ULCSAFM UL only Cert ID: 817820

type gujt boxes cover gujt type cover boxes conduit 100 outlet 100cs iron hazardous location gujc conductors gujx gujlb

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "BA21BA21Effective Copyright 2007 www.o-..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

BA21BA21Effective Copyright 2007 www.o-
BA21BA21Effective Copyright 2007 www.o-zgedney.comHazardous Location Fittings & Outlet Boxes Trade Size Catalog Catalog Number NumberMalleable Malleable Iron Iron Cover/ Cover/Body Malleable Malleable Iron Body UL/CSA/FM UL only Certified with Ground Screw/Lug GUJT-50 GUJT-50CS GUJT-75 GUJT-75CS 1 GUJT-100 GUJT-100CS GUJT-125 GUJT-125CS GUJT-150 GUJT-150CS 2 GUJT-200 GUJT-200CS 1 GUJE-100 GUJE-100CS 1 GUJL-100 GUJL-100CS 1 GUJC-100 GUJC-100CS 1 GUJLB-100 GUJLB-100CS 1 GUJX-100 GUJX-100CSConduit Outlet Boxes Type GUJWith overlapping threaded covers (Jar-style cover)To provide access to conductors for pulling, upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends.• Smooth hub bushings protect insulation when pulling conductors.• Cast-in brackets on cover for use with breaker-bar tools for tightening/loosening.• Suitable for wet locations when mounted in upright position.• No risk of conductor insulation damage from threads on base during pulling.• No risk of “pinching” conductors during cover • Improved wiring room• Tapered threaded hubs (NPT)• Dome cover available, see Page BA27Malleable Iron Cover and Body/Zinc Hot

Dip or Mechanical Galvanized. Add suffi
Dip or Mechanical Galvanized. Add suffix “G” to standard catalog number.Contact your local representative for pricing and availability.Third Party Certification:UL Listed: E-30513 Class I, Div. 1, 2, Groups C, DClass II, Div. 1, 2, Groups E, F, GSuitable for wet locations in upright position only.CSA Certified: 020945Applicable Third Party Standards:UL Standard: 886CSA: C22.2 No. 30NEC Articles 500-503 & 505Mil. Spec: Mil-F-28675Fed. Spec: A-A-50563Type GUJTType GUJEType GUJLType GUJCType GUJLBType GUJXHazardous location conduit outlet boxes shall be used in hazardous locations to provide for change in conduit direction, access to conductors, increased wiring volume and as pull and splice boxes. They shall be malleable iron with overlapping threaded covers and cast in brackets on the cover. The boxes shall be UL Listed, and suitable for wet locations. Hazardous location conduit outlet boxes shall be O-Z/Gedney Type GUJ.See Pages BA22 and BA23.BA23BA23Effective Copyright 2007 www.o-zgedney.comHazardous Location Fittings & Outlet BoxesConduit Outlet Boxes Type GUJCType GUJLBType GUJX Catalog Trade Cover VolumeNumber Size A B C D E Opening Cu. In.