Download aaron | 2017-12-07 | General 573 Industrial Chilled Mirror Hygrometer . 573 Content. Overview. Versions. Key features . Applications. Competitors. Target markets. Sales Promotion. June 2017. © MBW Calibration. Slide . 2. 573 . ID: 613162

Product Presentation PowerPoint Presentation, PPT - DocSlides Slideshow

50

aaron
By aaron

Watch All docs

  • Views 18
Download this presentation

Product Presentation PowerPoint Presentation, PPT - DocSlides

Click below link (As may be) to get this presentation.

Download Note - The PPT/PDF document "Product Presentation PowerPoint Presenta..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.

Presentations text content in Product Presentation PowerPoint Presentation, PPT - DocSlides

Slide1

Product Presentation

573 Industrial Chilled Mirror Hygrometer

Slide2

573 Content

OverviewVersionsKey features ApplicationsCompetitorsTarget marketsSales Promotion

June 2017

© MBW Calibration

Slide 2

Slide3

573 Overview

Precise chilled mirror dew point hygrometerIntegrated measuring headHead and inlet sample path heatingIntegrated head pressure measurementInternal sample pumpORISForce Frost functionOptional user programmable analogue outputsRS-232 serial interfaceIntuitive color touch screen user interfaceUser verifiable calibrationSCS 17025 calibration option

© MBW Calibration

Slide 3

June 2017

Slide4

573 Versions

573S SH3 measuring head-60…+20 °C frost/dew pointNo head/sample path heating573H SH3H heated measuring head-60…+70 °C frost/dew point Heating to 80 °C573HX HX measuring head-50…+95 °C frost/dew point Heating to 115 °C

© MBW Calibration

Slide 4

June 2017

Slide5

573S

Non heated 573Equivalent to 973SProvides rack mounting option

© MBW Calibration

Slide 5

June 2017

Slide6

573H

Heated measuring head (80 °C maximum)Heated internal inlet and outlet sample tubesConnection and control for inlet heated sample hoseSteam trap option on outlet

© MBW Calibration

Slide 6

June 2017

Slide7

573HX

Heated measuring head (115 °C maximum)Heated internal inlet and outlet sample tubesConnection and control for inlet heated sample hoseSteam trap option on outlet

© MBW Calibration

Slide 7

June 2017

Slide8

573 Key Features and USP

Features and Benefits of the MBW 573

Slide9

573 Backwards Compatibility

© MBW Calibration

Slide 9

DP3, DP5, DP8, DP30 ‘drop in’ replacementClassic instruments, many remain in use 10…30 years after supply

June 2017

Slide10

573 Key FeatureIntegral measuring head

Measuring head is outside the humidity generatorNo interruption of humidity generator operationDuring mirror cleaning

© MBW Calibration

Slide 10

June 2017

Slide11

573 Key FeatureHeated Measuring Head

Measuring head heated to stop condensationAlso internal sample tubesEnables dew points up to +95 °C

© MBW Calibration

Slide 11

June 2017

Slide12

573 Key FeatureHeated External Sample Hose

573 includes power and control for inlet heated sample hoseTemperature up to 115 °C

June 2017

© MBW Calibration

Slide 12

Slide13

573 Key Feature Steam trap

Condensation ‘trap’ after measuring headPrevents liquid water reaching the flow meter and sample pump

June 2017

© MBW Calibration

Slide 13

Slide14

573 Key Feature19” Rack mounting

For integration in to panels and racksPreferred in industrial installations

June 2017

© MBW Calibration

Slide 14

Slide15

573 Key FeatureInternal Sample Pump

Used for ‘pulling’ sample gasPump power can be controlled from the 573 front panelFlow rate can be adjusted using the rotameter built in to the 573Recommended flow 0.5 lpm (1 lpm for low humidity).

June 2017

© MBW Calibration

Slide 15

Slide16

573 Key FeatureOptimal Response Injection System

ORISUnique to MBWMeasurements at low humidity stabilise faster573S only

June 2017

© MBW Calibration

Slide 16

Slide17

573 Key FeatureAdditional Water Cooling

Connection of fluid to measuring headPre cools the mirrorEnables 573 to reach lower frost pointsHelp mirror cooling when ambient temperatures are high

© MBW Calibration

Slide 17

June 2017

Slide18

573 Key FeatureMechanical Flow Meter

Compliments internal electronic flow sensorManual flow control within instrument

June 2017

© MBW Calibration

Slide 18

Slide19

573 Key FeatureConfigurable Sample Path

Allows the user to isolate internal componentsMechanical flow meterSample pumpSteam trap between measuring head output and flow meter input

© MBW Calibration

Slide 19

June 2017

Slide20

573 Dew Point Hygrometer

Maintenance, Calibration, Spares

And Known Issues….

Slide21

573 Maintenance

Very little maintenance requirement:CalibrationOne or two year intervalsInterim checks (Ice Test)Mirror cleaningBefore starting measurementAs required after mirror checksMake sure sample loops are in good condition and correctly connected

© MBW Calibration

Slide 21

June 2017

Slide22

573 Calibration

Standard factory calibrationDew points -20, 1, 20, 40 and 60 °C, Temperature 5, 25 and 50 °CSCS 17025 calibration upgrade± 0.05 °C dew point, ± 0.01 %rh, ± 0.2…0.9 %rh uncertaintyRecalibration at any 17025 accredited laboratoryAdjustment should never be requiredStability/drift documented not adjustedException, temperature if PRT is damagedNew probe CvD coefficients can be applied under supervision

© MBW Calibration

Slide 22

June 2017

Slide23

573 User Interim Calibration Checks

Ice Test FunctionConfirms dew point temperature measurement stabilityWorks on the fundamental ice melting temperature

© MBW Calibration

Slide 23

June 2017

Slide24

573 Mirror Cleaning

Mirror cleaning is really important for good resultsMBW mirror design always allows for easy mirror access and cleaningUse sterile cotton budsUse alcohol (IPA/Ethanol) if hydrocarbon deposits are possibleAlways finish with distilled water

© MBW Calibration

Slide 24

June 2017

Slide25

573 Suggested Spares

Optical modulesHeated hoseSample pump

© MBW Calibration

Slide 25

June 2017

Slide26

573 Known Issues and Solutions

573 has the lowest level of support casesMost recent development team effortsMost recent electronic platformTemperature sensor connection on internal heated componentsModified connectionsCondensation in internal heated tubesModified temperature measurement positionHead mount difficult to remove during serviceRevised mechanical design

© MBW Calibration

Slide 26

June 2017

Slide27

International Support

Service centers:MBW SwitzerlandRH Systems USASupertron SingaporeShanghai RayGe ChinaRotronic UKGrowing network of business partners

© MBW Calibration

Slide 27

June 2017

Slide28

573 Dew Point Hygrometer

Marketing and Promotion

Slide29

573 Applications

Examples of where the 573 is used

Slide30

573 Application

Accredited calibration and test laboratoriesWide dew point rangeEspecially useful for high humidity conditions573H and HXAlso suitable for low humidity (-50 °C FP)Dual functionality for labs with limited budgets 2nd mirror PRT option

© MBW Calibration

Slide 30

June 2017

Slide31

573 Application

Humidity Sensor Production and Test SystemsOften in Combination with G1 humidity generator19” rack mountingInterface with manufacturing systemsSerial communicationAutomated controlAutomated calibrationCustomised solutionsManufacturer specificNDA in all casesWe have the know how and experience

© MBW Calibration

Slide 31

June 2017

Slide32

573 Application – Production Calibration

© MBW Calibration

Slide 32

T12

Thermometer

Serial Interface to Gecko/

LabVIEWPRT

573 Reference InstrumentControls inlet tube temperatureSerial Interface to Gecko/LabVIEWPRT

G1 Humidity GeneratorSerial Interface to Gecko/LabVIEWPRT

Sensor Sub Chamber

Test System

Temperature controller for heated tube

June 2017

Slide33

573 Application

Fuel Cell ResearchMeasurement of humidity in anode and cathode gas streamsHigh temperature and high dew pointHeated sample path provides reliable sampling373 is better though…Closed loop sampling

© MBW Calibration

Slide 33

June 2017

Slide34

573 Application

RH Generator Transfer Standard

Enables lower calibration uncertaintyContinuous generator verification (e.g. in laboratory conditions)Verification of RH control probe calibrationCompatible with all types of RH generatorExternal measuring head advantageMirror cleaningThermal gradients

© MBW Calibration

Slide 34

June 2017

Slide35

573 Application

Climatic chamber validationIEC 60068 Standard method*Dew point measurementCalculated RH values at multiple pointsData acquisition using serial interfaceT12 thermometer integration within Gecko

© MBW Calibration

Slide 35

* Also as DKD_R_5_7_e, Euramet cg 20, NF X 15 40

June 2017

Slide36

573 Application

Heat treatment of metalsAnnealingSinteringCarburizingInert dry gasesPrecise humidity measurement and control improves qualitySampling from furnaces

© MBW Calibration

Slide 36

June 2017

Slide37

573 Applications

From your countries?

June 2017

© MBW Calibration

Slide

37

Slide38

573 Dew Point Hygrometer

Marketing and Promotion

Slide39

573 Competitors

Other products that customers consider

Slide40

573 Competitors

Edgetech DPS3-35…+95 °C DP± 0.2 claimed accuracyOptional pressure and data processingHeated enclosureRelatively new….

© MBW Calibration

Slide 40

June 2017

Slide41

573 Competitors

GE OpticaSIM12H heated measuring headHSS-12 sampling system± 0.2 claimed accuracySignificant temperature coefficientMeasuring head design from 1980sPoor supportPoor reliabilityIf someone is using this… an MBW will be a revelation (if they can get budget!).

June 2017

© MBW Calibration

Slide 41

Slide42

573 Competitors

Shinyei DewStarUnsure price position0…95 °C DP range± 0.2 claimed accuracyNeeds optional sample gas flow moduleLimited support outside Japan

© MBW Calibration

Slide 42

source: http://www.shinyei.co.jp/stc/eng/humidity/main_DewStar-R1.html

June 2017

Slide43

573 Competitors

Michell Optidew, Optidew VisionTypically 70…80% cheaper± 0.2 claimed accuracyWide range of variations including 130 °C head temperatureNot heated, so measuring head has to fit in to the test conditionNot an elegant solutionDifferent class of instrument, but still used

© MBW Calibration

Slide 43

source: http://www.michell.com/us/products/optidew_vision.htm

June 2017

Slide44

573 Competitors

Michell S8000 RemoteTypically 50…60% cheaper± 0.1 claimed accuracyWide range of variations including 130 °C head temperatureNot heated, so measuring head has to fit in to the test conditionNot an elegant solution

© MBW Calibration

Slide 44

June 2017

Slide45

Mirror Performance Comparison

INTA Spain 20124 ManufacturersMBW, Michell, GE, Edgetech17 Instruments1997 to 2010 calibration historyAccuracyStabilityTemperature CoefficientsFor your evaluationUseful support for MBW products!

June 2017

© MBW Calibration

Slide 45

Slide46

573 Competitors - Position

The 573 is the ‘high end solution’ that users turn to when alternatives are not reliableDrivers to upgrade to 573 from lower quality chilled mirrorsBetter temperature coefficients Better performance at high dew point conditionsBetter stability in useHigher ReliabilityBetter long term stabilitySupporting the 573Advanced featuresMBW good reputationExisting user experience with MBWQuality, stability and longevityLower cost of ownership in real use

© MBW Calibration

Slide 46

June 2017

Slide47

573 Promotion

Where to Promote the 573

Slide48

573 Target Markets

RH instrument manufacturers and usersTransfer standard for lower uncertainty RH calibrationClimatic test chamber manufacturers and usersR&D, calibration and maintenance departmentsMetal industryHeat treatment processes

© MBW Calibration

Slide 48

June 2017

Slide49

573 Promotion

Opportunity Development:Known DP3, DP30, DP8, DP5 usersClimatic Chamber manufacturers and distributorse.g. Weiss, Vötsch, Climats, Espec, PGC, AralabAccredited calibration laboratories

© MBW Calibration

Slide 49

June 2017

Slide50

Thank You for Your Attention!

Any Questions?

June 2017

© MBW Calibration

Slide

50

Recommended

Advertisement

The Future of the Legal Profession
  • 16

The Future of the Legal Profession

Intravenous Solutions, Equipment, and Calculations
  • 18

Intravenous Solutions, Equipment, and Calculations

DEMENTIA, ANOTHER COMPLICATION OF DIABETES
  • 25

DEMENTIA, ANOTHER COMPLICATION OF DIABETES

Diabolical Devotions:
  • 13

Diabolical Devotions:

Sindhi Optical Character Recognition
  • 26

Sindhi Optical Character Recognition

Rev. 19:1-5
  • 14

Rev. 19:1-5

Use of Diagnosed Conditions for IDEA Part C Early Intervent
  • 25

Use of Diagnosed Conditions for IDEA Part C Early Intervent

Diagnosing Forecast Errors in Tropical Cyclone Motion
  • 27

Diagnosing Forecast Errors in Tropical Cyclone Motion

Report this Document.