Product Presentation PowerPoint Presentation, PPT - DocSlides

Download

  • Likes: 1
  • Views: 1
  • aaron

Description

Product Presentation PowerPoint Presentation, PPT - DocSlides - 573 Industrial Chilled Mirror Hygrometer . 573 Content. Overview. Versions. Key features . Applications. Competitors. Target markets. Sales Promotion. June 2017. © MBW Calibration. Slide . 2. 573 .

Download this presentation

Product Presentation PowerPoint Presentation, PPT - DocSlides

Click below link (As may be) to download this presentation.

Download Note - The PPT/PDF document "Product Presentation PowerPoint Presenta..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.

Product Presentation PowerPoint Presentation, PPT - DocSlides

    Slide1

    Product Presentation

    573 Industrial Chilled Mirror Hygrometer

    Slide2

    573 Content

    OverviewVersionsKey features ApplicationsCompetitorsTarget marketsSales Promotion

    June 2017

    © MBW Calibration

    Slide 2

    Slide3

    573 Overview

    Precise chilled mirror dew point hygrometerIntegrated measuring headHead and inlet sample path heatingIntegrated head pressure measurementInternal sample pumpORISForce Frost functionOptional user programmable analogue outputsRS-232 serial interfaceIntuitive color touch screen user interfaceUser verifiable calibrationSCS 17025 calibration option

    © MBW Calibration

    Slide 3

    June 2017

    Slide4

    573 Versions

    573S SH3 measuring head-60…+20 °C frost/dew pointNo head/sample path heating573H SH3H heated measuring head-60…+70 °C frost/dew point Heating to 80 °C573HX HX measuring head-50…+95 °C frost/dew point Heating to 115 °C

    © MBW Calibration

    Slide 4

    June 2017

    Slide5

    573S

    Non heated 573Equivalent to 973SProvides rack mounting option

    © MBW Calibration

    Slide 5

    June 2017

    Slide6

    573H

    Heated measuring head (80 °C maximum)Heated internal inlet and outlet sample tubesConnection and control for inlet heated sample hoseSteam trap option on outlet

    © MBW Calibration

    Slide 6

    June 2017

    Slide7

    573HX

    Heated measuring head (115 °C maximum)Heated internal inlet and outlet sample tubesConnection and control for inlet heated sample hoseSteam trap option on outlet

    © MBW Calibration

    Slide 7

    June 2017

    Slide8

    573 Key Features and USP

    Features and Benefits of the MBW 573

    Slide9

    573 Backwards Compatibility

    © MBW Calibration

    Slide 9

    DP3, DP5, DP8, DP30 ‘drop in’ replacementClassic instruments, many remain in use 10…30 years after supply

    June 2017

    Slide10

    573 Key FeatureIntegral measuring head

    Measuring head is outside the humidity generatorNo interruption of humidity generator operationDuring mirror cleaning

    © MBW Calibration

    Slide 10

    June 2017

    Slide11

    573 Key FeatureHeated Measuring Head

    Measuring head heated to stop condensationAlso internal sample tubesEnables dew points up to +95 °C

    © MBW Calibration

    Slide 11

    June 2017

    Slide12

    573 Key FeatureHeated External Sample Hose

    573 includes power and control for inlet heated sample hoseTemperature up to 115 °C

    June 2017

    © MBW Calibration

    Slide 12

    Slide13

    573 Key Feature Steam trap

    Condensation ‘trap’ after measuring headPrevents liquid water reaching the flow meter and sample pump

    June 2017

    © MBW Calibration

    Slide 13

    Slide14

    573 Key Feature19” Rack mounting

    For integration in to panels and racksPreferred in industrial installations

    June 2017

    © MBW Calibration

    Slide 14

    Slide15

    573 Key FeatureInternal Sample Pump

    Used for ‘pulling’ sample gasPump power can be controlled from the 573 front panelFlow rate can be adjusted using the rotameter built in to the 573Recommended flow 0.5 lpm (1 lpm for low humidity).

    June 2017

    © MBW Calibration

    Slide 15

    Slide16

    573 Key FeatureOptimal Response Injection System

    ORISUnique to MBWMeasurements at low humidity stabilise faster573S only

    June 2017

    © MBW Calibration

    Slide 16

    Slide17

    573 Key FeatureAdditional Water Cooling

    Connection of fluid to measuring headPre cools the mirrorEnables 573 to reach lower frost pointsHelp mirror cooling when ambient temperatures are high

    © MBW Calibration

    Slide 17

    June 2017

    Slide18

    573 Key FeatureMechanical Flow Meter

    Compliments internal electronic flow sensorManual flow control within instrument

    June 2017

    © MBW Calibration

    Slide 18

    Slide19

    573 Key FeatureConfigurable Sample Path

    Allows the user to isolate internal componentsMechanical flow meterSample pumpSteam trap between measuring head output and flow meter input

    © MBW Calibration

    Slide 19

    June 2017

    Slide20

    573 Dew Point Hygrometer

    Maintenance, Calibration, Spares

    And Known Issues….

    Slide21

    573 Maintenance

    Very little maintenance requirement:CalibrationOne or two year intervalsInterim checks (Ice Test)Mirror cleaningBefore starting measurementAs required after mirror checksMake sure sample loops are in good condition and correctly connected

    © MBW Calibration

    Slide 21

    June 2017

    Slide22

    573 Calibration

    Standard factory calibrationDew points -20, 1, 20, 40 and 60 °C, Temperature 5, 25 and 50 °CSCS 17025 calibration upgrade± 0.05 °C dew point, ± 0.01 %rh, ± 0.2…0.9 %rh uncertaintyRecalibration at any 17025 accredited laboratoryAdjustment should never be requiredStability/drift documented not adjustedException, temperature if PRT is damagedNew probe CvD coefficients can be applied under supervision

    © MBW Calibration

    Slide 22

    June 2017

    Slide23

    573 User Interim Calibration Checks

    Ice Test FunctionConfirms dew point temperature measurement stabilityWorks on the fundamental ice melting temperature

    © MBW Calibration

    Slide 23

    June 2017

    Slide24

    573 Mirror Cleaning

    Mirror cleaning is really important for good resultsMBW mirror design always allows for easy mirror access and cleaningUse sterile cotton budsUse alcohol (IPA/Ethanol) if hydrocarbon deposits are possibleAlways finish with distilled water

    © MBW Calibration

    Slide 24

    June 2017

    Slide25

    573 Suggested Spares

    Optical modulesHeated hoseSample pump

    © MBW Calibration

    Slide 25

    June 2017

    Slide26

    573 Known Issues and Solutions

    573 has the lowest level of support casesMost recent development team effortsMost recent electronic platformTemperature sensor connection on internal heated componentsModified connectionsCondensation in internal heated tubesModified temperature measurement positionHead mount difficult to remove during serviceRevised mechanical design

    © MBW Calibration

    Slide 26

    June 2017

    Slide27

    International Support

    Service centers:MBW SwitzerlandRH Systems USASupertron SingaporeShanghai RayGe ChinaRotronic UKGrowing network of business partners

    © MBW Calibration

    Slide 27

    June 2017

    Slide28

    573 Dew Point Hygrometer

    Marketing and Promotion

    Slide29

    573 Applications

    Examples of where the 573 is used

    Slide30

    573 Application

    Accredited calibration and test laboratoriesWide dew point rangeEspecially useful for high humidity conditions573H and HXAlso suitable for low humidity (-50 °C FP)Dual functionality for labs with limited budgets 2nd mirror PRT option

    © MBW Calibration

    Slide 30

    June 2017

    Slide31

    573 Application

    Humidity Sensor Production and Test SystemsOften in Combination with G1 humidity generator19” rack mountingInterface with manufacturing systemsSerial communicationAutomated controlAutomated calibrationCustomised solutionsManufacturer specificNDA in all casesWe have the know how and experience

    © MBW Calibration

    Slide 31

    June 2017

    Slide32

    573 Application – Production Calibration

    © MBW Calibration

    Slide 32

    T12

    Thermometer

    Serial Interface to Gecko/

    LabVIEWPRT

    573 Reference InstrumentControls inlet tube temperatureSerial Interface to Gecko/LabVIEWPRT

    G1 Humidity GeneratorSerial Interface to Gecko/LabVIEWPRT

    Sensor Sub Chamber

    Test System

    Temperature controller for heated tube

    June 2017

    Slide33

    573 Application

    Fuel Cell ResearchMeasurement of humidity in anode and cathode gas streamsHigh temperature and high dew pointHeated sample path provides reliable sampling373 is better though…Closed loop sampling

    © MBW Calibration

    Slide 33

    June 2017

    Slide34

    573 Application

    RH Generator Transfer Standard

    Enables lower calibration uncertaintyContinuous generator verification (e.g. in laboratory conditions)Verification of RH control probe calibrationCompatible with all types of RH generatorExternal measuring head advantageMirror cleaningThermal gradients

    © MBW Calibration

    Slide 34

    June 2017

    Slide35

    573 Application

    Climatic chamber validationIEC 60068 Standard method*Dew point measurementCalculated RH values at multiple pointsData acquisition using serial interfaceT12 thermometer integration within Gecko

    © MBW Calibration

    Slide 35

    * Also as DKD_R_5_7_e, Euramet cg 20, NF X 15 40

    June 2017

    Slide36

    573 Application

    Heat treatment of metalsAnnealingSinteringCarburizingInert dry gasesPrecise humidity measurement and control improves qualitySampling from furnaces

    © MBW Calibration

    Slide 36

    June 2017

    Slide37

    573 Applications

    From your countries?

    June 2017

    © MBW Calibration

    Slide

    37

    Slide38

    573 Dew Point Hygrometer

    Marketing and Promotion

    Slide39

    573 Competitors

    Other products that customers consider

    Slide40

    573 Competitors

    Edgetech DPS3-35…+95 °C DP± 0.2 claimed accuracyOptional pressure and data processingHeated enclosureRelatively new….

    © MBW Calibration

    Slide 40

    June 2017

    Slide41

    573 Competitors

    GE OpticaSIM12H heated measuring headHSS-12 sampling system± 0.2 claimed accuracySignificant temperature coefficientMeasuring head design from 1980sPoor supportPoor reliabilityIf someone is using this… an MBW will be a revelation (if they can get budget!).

    June 2017

    © MBW Calibration

    Slide 41

    Slide42

    573 Competitors

    Shinyei DewStarUnsure price position0…95 °C DP range± 0.2 claimed accuracyNeeds optional sample gas flow moduleLimited support outside Japan

    © MBW Calibration

    Slide 42

    source: http://www.shinyei.co.jp/stc/eng/humidity/main_DewStar-R1.html

    June 2017

    Slide43

    573 Competitors

    Michell Optidew, Optidew VisionTypically 70…80% cheaper± 0.2 claimed accuracyWide range of variations including 130 °C head temperatureNot heated, so measuring head has to fit in to the test conditionNot an elegant solutionDifferent class of instrument, but still used

    © MBW Calibration

    Slide 43

    source: http://www.michell.com/us/products/optidew_vision.htm

    June 2017

    Slide44

    573 Competitors

    Michell S8000 RemoteTypically 50…60% cheaper± 0.1 claimed accuracyWide range of variations including 130 °C head temperatureNot heated, so measuring head has to fit in to the test conditionNot an elegant solution

    © MBW Calibration

    Slide 44

    June 2017

    Slide45

    Mirror Performance Comparison

    INTA Spain 20124 ManufacturersMBW, Michell, GE, Edgetech17 Instruments1997 to 2010 calibration historyAccuracyStabilityTemperature CoefficientsFor your evaluationUseful support for MBW products!

    June 2017

    © MBW Calibration

    Slide 45

    Slide46

    573 Competitors - Position

    The 573 is the ‘high end solution’ that users turn to when alternatives are not reliableDrivers to upgrade to 573 from lower quality chilled mirrorsBetter temperature coefficients Better performance at high dew point conditionsBetter stability in useHigher ReliabilityBetter long term stabilitySupporting the 573Advanced featuresMBW good reputationExisting user experience with MBWQuality, stability and longevityLower cost of ownership in real use

    © MBW Calibration

    Slide 46

    June 2017

    Slide47

    573 Promotion

    Where to Promote the 573

    Slide48

    573 Target Markets

    RH instrument manufacturers and usersTransfer standard for lower uncertainty RH calibrationClimatic test chamber manufacturers and usersR&D, calibration and maintenance departmentsMetal industryHeat treatment processes

    © MBW Calibration

    Slide 48

    June 2017

    Slide49

    573 Promotion

    Opportunity Development:Known DP3, DP30, DP8, DP5 usersClimatic Chamber manufacturers and distributorse.g. Weiss, Vötsch, Climats, Espec, PGC, AralabAccredited calibration laboratories

    © MBW Calibration

    Slide 49

    June 2017

    Slide50

    Thank You for Your Attention!

    Any Questions?

    June 2017

    © MBW Calibration

    Slide

    50

Report this Document.

  • Creating Content

    Creating Content

    725-views
  • Clipper: A Low Latency Online Prediction Serving System

    Clipper: A Low Latency Online Prediction Serving System

    695-views
  • Claims, Evidence, and Warrants

    Claims, Evidence, and Warrants

    605-views
  • You Can Choose Engineered Timber Flooring In Melbourne

    You Can Choose Engineered Timber Flooring In Melbourne

    781-views
  • Gaucho Round-Up

    Gaucho Round-Up

    735-views
  • SCADA in electrical power delivery

    SCADA in electrical power delivery

    754-views
  • A Century of Turmoil

    A Century of Turmoil

    724-views
  • Theories of evolution

    Theories of evolution

    786-views
  • Drones Collecting Cell Phone Data in

    Drones Collecting Cell Phone Data in

    777-views
  • Fossil Collecting:

    Fossil Collecting:

    745-views