147There is no practical limitation to the number of electrodes t 147There is no practical limitation to the number of electrodes t

147There is no practical limitation to the number of electrodes t - PDF document

scarlett
scarlett . @scarlett
Follow
347 views
Uploaded On 2021-06-20

147There is no practical limitation to the number of electrodes t - PPT Presentation

Dewan MC et alJ Neurosurg 2017 Dec 1519 doi 10317120176JNS17881 microTargeting153 Solution for DIXI Medical Depth Electrode Placement FHC146s microTargeting153 solution for DIXI Me ID: 846190

depth dixi platform 5mm dixi depth 5mm platform vendor guide electrodes drill target 153 anchors waypoint wrench fhc electrode

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "147There is no practical limitation to t..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 * “There is no practical limitation
* “There is no practical limitation to the number of electrodes that can be implanted.” Dewan MC et al.J Neurosurg. 2017 Dec 15:1-9. doi: 10.3171/2017.6.JNS17881 microTargeting™ Solution for DIXI Medical Depth Electrode Placement FHC’s microTargeting™ solution for DIXI Medical SEEG depth electrodes provides guidance for the DIXI 2.5mm drill and 2.5mm wrench to accurately place DIXI Anchor Bolts and Depth Electrodes using WayPoint™ bone anchors serving as ducials, and a patient-customized microTargeting Multi-Oblique Platform created with WayPoint Navigator software. Over twenty independent trajectories may be congured with a single platform. Once the platform is attached, all of the trajectories are available for implantation. This allows for rapid progression between trajectories as well as the possibility of simultaneous use by multiple surgeons. that allow both localization and treatment to be performed using the same technology. WayPoint bone anchors serving as ducials are placed in clinical setting 7-28 days before surgery No restrictions on positioning of the anchors, selecting the trajectory entry point or orientation Supports implantation of all SEEG depth electrodes using a single platform Patient-customized platform quickly attaches to bone anchors in OR Anchors and scans may be reused for subsequent microTargeting treatment solutions Platform delivered to hospital in 5 days an unlimited number* of DIXI SEEG depth electrodes using DIXI skull bolts, drill and wrench. microTargeting™ and WayPoint™ are trademarks of FHC,

2 Inc. www.fh-co.com Ordering Information
Inc. www.fh-co.com Ordering Information: Reusable tools/planning software: 66-ST-MO – Sterilization tray, ruler, cleaning brush 66-MO-05 – 2.5mm Tool Guide 66-WP-NV (4.5) – WayPoint Navigator Per case: MP-KIT-P-EO – Multi trajectory oblique platform Additional Items Required for Operation: (vendor) DIXI bone starter (vendor) DIXI 2.5mm Drill (vendor) DIXI electrocoagulation electrode (vendor) DIXI skull bolts (vendor) DIXI 2.5mm Wrench (vendor) DIXI marking rod and rulers (vendor) DIXI stylet (vendor) DIXI depth electrodes L022-05 (Rev C0, 2018-11-28) Procedure Overview: 1. Use 2.5mm Tool Guide (66-MO-04) to guide DIXI drill through Skull. 2. Use 2.5mm Tool Guide to screw DIXI bolt into the hole using DIXI wrench. 3. Use DIXI Marking rod to measure distance from top of guide to bolt. 4. Calculate position for DIXI Bolt cap and position on DIXI depth electrode. 5. Follow DIXI procedure to insert and secure DIXI depth electrode. 15mm 10mm Target Depth (TD) Target Skull Platform Hub DIXI Drill Bit DIXI Drill Stop 2.5mm Tool Guide Target Depth (TD) Target DIXI Bolt 2.5mm Tool Guide Anchor Wrench (TD+10-D2) Target DIXI Depth Electrode DIXI Bolt Cap 10mm D2 Target Depth (TD) DIXI Marking Rod Simple stopTarget ~ ~ FHC Latin America Calle 6 Sur Cra 43 A-200 Edicio LUGO Ocina 1406 Medellín-Colombia 24 hour technical service: 1-800-326-2905 - (US & Can) +1-207-666-8190 FHC, Inc. 1201 Main Street Bowdoin, ME 04287 USA Fax: +1-207-666-8292 www.fh-co.com FHC Europe (TERMOBIT PROD srl) 42A Barbu Vacarescu Str, 3rd Fl Bucharest 020281 Sector 2 Romania www.fh-co.com