Date: 17.06.2017	Incident Date: 17.06.2017	Incident

Date: 17.06.2017 Incident - PowerPoint Presentation

trinity
trinity . @trinity
Follow
64 views
Uploaded On 2023-12-30

Date: 17.06.2017 Incident - PPT Presentation

LTI What happened During process of Derrickman DM changeover Floorman FM relieved DM and pulled amp racked back a stand of pipe DM was standing close to ladder with fall arrester attached in preparation to descend down the ladder Driller lowered Top Drive System TDS which entang ID: 1036086

ensure changeover incident stationary changeover ensure stationary incident board monkey level arrester fall company derrickman block procedure tds driller

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Date: 17.06.2017 Incident" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1. Date: 17.06.2017 Incident: LTIWhat happened?During process of Derrickman (DM) changeover, Floorman (FM) relieved DM and pulled & racked back a stand of pipe. DM was standing close to ladder with fall arrester attached in preparation to descend down the ladder. Driller lowered Top Drive System (TDS) which entangled and pulled the fall arrester line along with DM. DM fell (same level) at monkey board platform with left leg trapped between monkey board post & guide beam resulting in a fracture to his left ankle. Your learning from this incident..Always ensure the TDS is stationary until DM changeover is completeEnsure communication between Driller and DM at all timesEnsure right Fall Arrester is used at all times Always ensure travelling block is stationary during DM changeover1PDO Second AlertBlock movingBlock stationary at Rig Floor level during changeoverBlock moving at monkey board level during changeover

2. As a learning from this incident and ensure continual improvement all contractmanagers must review their HSE HEMP against the questions asked below Confirm the following:Do you have a Derrickman Changeover procedure in your company? Does it mention that the block should be stationary at the time of DM changeover?Did you evaluate the possibility of use of Lad-Safe on your Derricks?Do you have Rescue from Height procedure in your company?Do you hold Drills for Rescue from Height?Do you apply consequence management where necessary?Do you ensure adequate competency levels for all staff?Management self audit 2Date: 17.06.2017 Incident: LTI