2 CABLE MANUFACTURINGReka Cables Ltd offers highquality cables for various needs Our safe stateofthe art products are manufactured from the best materialsWe are the largest Finnish cable manufac ID: 842031

core copper weight free copper core free weight circular black blue stranded cable brown resistant screen installation laid yellow

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "PRODUCT CATALOG" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 PRODUCT CATALOG 2 CABLE MANUFACTURINGRek
PRODUCT CATALOG 2 CABLE MANUFACTURINGReka Cables Ltd offers high-quality cables for various needs. Our safe, state-of-the art products are manufactured from the best materials.We are the largest Finnish cable manufacturer. All our cables have been manufactured in our own factories in Finland. We are well located in Northern Europe for

2 fast and reliable logistic routes to cus
fast and reliable logistic routes to customers in the region.We are well-known for our exibility and customer-oriented mindset. We develop continuously our processes to offer are always there to help. Availability of products is secured with own buffer stocks and availability planning with customers. application areasWe invest in

3 installer-friendliness of our products.
installer-friendliness of our products. Our cables are easy to strip and handle, making installation quick and ergonomic. Further, the quality of our products play an important role in the operational reliability, safety and longevity. Demanding Nordic weather conditions are taken into account in product design. Due to a wide product o

4 ffering Reka can offer a comprehensive a
ffering Reka can offer a comprehensive and economic solution for any need. 3 INDUSTRYENERGY INDUSTRY LICATIOur diverse selection offers cables for various applications, In addition to high-quality products, we offer great service. Our technical support ensures that each customer is provided with suitable solutions and answers all Re

5 sidential buildings Obuildings Hospitals
sidential buildings Obuildings Hospitals,schools andother publicbuildings Industry Tunnels, structure Wind farms production Network construction 4 260employees Turnover EURAll cables are manufactured in Finland.We have three production sites; in Hyvinkää, Riihimäki and We are internationalOur home markets are the Nordic countires, t

6 he Baltics and Russia with local sales r
he Baltics and Russia with local sales representatives. We also export cables HOME MARKETS Operating in 7countriesMain ofce, Hyvinkää Factory Sales ofce Established 1961 manufactured delivered 5 PRODUCT FAMILIESTALLATI • Halogenfree • Fullyrecyclable • Lowproduction�re • UV-protected • •Improvedpro

7 perties •resistantSTANDARD • High â€
perties •resistantSTANDARD • High • Wellproperties • HalogenfreefreeTANT • Ablecircuit�re • Halogenfree • Lowproduction�re • Slow�respreadLTAGE • Voltage • First • Outstandingreliability 6 We want to make the highest quality of cables to our customers. Our products are developed in

8 our research and product and with own p
our research and product and with own production facilities, we can ensure highest quality, excellent installation properties and long lasting products.We test the products in our testing laboratories to ensure their quality and durability. The products and their components strength •Frostresistance •resistancestrength •FireWe c

9 arry out comprehensive CPR tests on our
arry out comprehensive CPR tests on our products in Cable Test Center, a re testing laboratory we opened in 7 ble manufacturing plant. We also produce high voltage cables at Riihimäki, from the drawing of aluminium wire to the testing manufacturespecialises in installation, control, connection, telecoms network and coupling cab

10 les as well as re resistant and hal
les as well as re resistant and halogen free cables. The copper wire drawing for all our factories’ needs are centralized in Keuruu. CATI 8 concern.tional health and safety, the well-being of employees, personal security, prevention of accidents and disruption, product safety, safe use and uency of products and services.

11 certied according to OHSAS 18001.W
certied according to OHSAS 18001.We ensure efcient, safe and disturbance-free production by investing in operations. We act in a cost-effective manner that The Reka spirit includes the principle of reliability: We are honest and open and keep our promises. We consider it a matter of honour to be available and provide our cus

12 tomers with professional, quick services
tomers with professional, quick services. 9 We take the environment into consideration in all our operations. We minimize the energy consumed and the waste created in our production and develop products with the least possible strain on the environment. We do not use hazardous chemicals and offer halogen free and fully recyclable alte

13 rnaWe procure our raw materials from sup
rnaWe procure our raw materials from suppliers who take the environment into consideration in their operations and we favour environmentally friendly, recyclable materials that do not release harmful substances into nature, soil or water systems. Our opproductsthe requirements of the RoHS directive 2011/65/EU. Our goal is to deliver no

14 thing but rst-rate products to our
thing but rst-rate products to our customers. We ensure quality control through regular auditing and ISO 9001 10 CO RODUCT C STALLATIOCA STALLATIOSTALLATIOSTALLATIOCASTALLATIOCACACACACACASTRUMETATIOCA CACA 11 RESISTACARESISTASTALLATIOCARESISTACARESISTACA OLTACAOLTACAICAL IFORMATIOIDENTIFICATIONTEMPERATURESCAPACITIESCAPACITIESCAP

15 ACITIESFORMATIOE TAcorecores.conductors
ACITIESFORMATIOE TAcorecores.conductors the nominal cross-sectional area is indicated in square a nominal diameter of the conductor.3x1.5 means that the cable has three 1.5 mm insulated cores. insulated cores and an uninsulated concentric wires of total cross sectional area of 6 mmThe diameters and weights are approximate.We reserve th

16 e right for changes. 12 EQQ LiteRexSS 42
e right for changes. 12 EQQ LiteRexSS 424 02 19-5 exWeight INSTALLATION CABLEHalogen free Circular, solid copperHalogen free polyolene Core3G-core: green/yellow, blue brown4G-core: green/yellow, blue, brown, black5G-core: green/yellow, blue, brown, black, greyfreeUV-resistant to be laid in soil nor directly in cast concrete. UV-

17 resistant 13 HHJ LiteRex CSS 424 02 19-
resistant 13 HHJ LiteRex CSS 424 02 19-5 ex Weight INSTALLATION CABLECircular, solid copperHalogen free polyolene Core3-core: green/yellow, blue brown4-core: green/yellow, blue brown, black5-core: green/yellow, blue, brown, black, grey: freeUV-resistantalso be used in medical facilities where higher re class is required. No

18 t to be laid in soil nor directly concre
t to be laid in soil nor directly concrete.areUV-resistant. 14 EQLQ LiteRexSS 424 02 19-6 exWeight INSTALLATION CABLEHalogen free, screenedCircular, solid copperHalogen free polyolene Core3G-core: green/yellow, blue brown4G-core: green/yellow, blue brown, black5G-core: green/yellow, blue, brown, black, greyHalogen free pastic tape

19 creen tinned copper wires 1 mm: Whitefr
creen tinned copper wires 1 mm: WhitefreeUV-resistant Not to be laid in soil nor directly in cast concrete.UV-resistant 15 16 MLEN 50525-2-31 Weight INSTALLATION WIRECircular, solid copper : PVC For xed installation in conduit and for internal 17 MK 90EN 50525-2-31 Weight INSTALLATION WIRE 90°Circular, stranded copper : PVC

20 For xed installation in conduit a
For xed installation in conduit and for internal conductor temperature 90 °C 18 MK 90EN 50525-2-31 Weight INSTALLATION WIRE 90° 19 MKEM 90EN 50525-2-31 diameter Weight INSTALLATION WIRE 90°Circular, exible copper : PVC For xed installation in conduit and for internal conductor temperature 90 °C 20 MKEM 90EN 50525

21 -2-31 Weight INSTALLATION WIRE 90° 21
-2-31 Weight INSTALLATION WIRE 90° 21 Circular, stranded copperHalogen free polyolene For xed installation in conduit and for internal Weight INSTALLATION WIREHalogen free 22 MK-HFEN 50525-3-31 Weight INSTALLATION WIREHalogen freeCircular, stranded copperHalogen free polyolene For xed installation in conduit

22 and for internal 23 Circular, exi
and for internal 23 Circular, exible copperHalogen free polyolene For xed installation in conduit and for internal Weight INSTALLATION WIREHalogen free 24 MKEM-HFEN 50525-3-31 Weight INSTALLATION WIREHalogen freeCircular, ne stranded copperHalogen free polyolene For xed installation in conduit and

23 for internal 25 INSTALLATION CABLECir
for internal 25 INSTALLATION CABLECircular, solid copper: PVCCore2-core: blue, brown3-core: green/yellow, blue, brown4-core: green/yellow, brown, black, grey4-core: green/yellow, blue, brown, black (1,5 5-core: green/yellow, blue, brown, black, greyWithout yellow/green and blue conductors.3-core: brown, black, grey4-core: blue, brow

24 n, black, grey5-core: blue, brown, black
n, black, grey5-core: blue, brown, black, grey, black: UV-resistant For xed installations indoors and outdoors. Not to be laid in soil nor directly in cast concrete. Core insulation must be protected against direct UV-lightluminaires. Weight 26 INSTALLATION CABLE Weight 27 INSTALLATION CABLE Weight Circular, stranded copper: P

25 VCCore3-core: green/yellow, blue, brown5
VCCore3-core: green/yellow, blue, brown5-core: green/yellow, blue, brown, black, grey: UV-resistant Not to be laid in soil nor directly in cast concrete Core insulation must be protected against direct sunlight 28 circular, solid copper circular, stranded copper Halogen free polyolene Core3-core: green/yellow, blue brown5-core:

26 green/yellow, blue, brown, black, greyHa
green/yellow, blue, brown, black, greyHalogen free lling sheath: WhitefreeUV-resistant to be laid in soil nor directly in cast concrete. Core insulations must be protected against directUV-lightluminaires Weight INSTALLATION CABLEHalogen free 29 Circular, solid copper: PVC,Core: UV-resistantNot to be laid in soil nor directly in

27 cast concrete Weight 30 Circular, soli
cast concrete Weight 30 Circular, solid copper: PVC,CoreLayer of copper wires and a copper tape: UV-resistant Weight 31 MMO-HFHD 627 7D-1 Weight Halogen freeCircular, solid copperHalogen free polyolene, black CoreHalogen free lling sheathfreeUV-resistant to be laid in soil nor directly in cast concrete 32 circular solid

28 aluminuium circular stranded aluminum :
aluminuium circular stranded aluminum : PVCCore3-Core: brown, black, grey4-Core: blue, brown, black, greyLayer of copper wires and a copper tape : UV-resistant Weight POWER CABLE 33 MCMKSFS 4880 HD 603-3F Weight POWER CABLE Circular, solid copper Circular, stranded copper: PVCCore2-Core: blue, brown3-Core: brown, black, grey4-Core: b

29 lue, brown, black, greyLayer of copper w
lue, brown, black, greyLayer of copper wires and a copper tape : UV-resistant 34 : PVCCore3-Core: brown, black, grey4-Core: blue, brown, black, greyLayer of copper wires and a copper tape: UV-resistant Weight POWER CABLE 35 AXCMK-HF Weight POWER CABLEHalogen free circular stranded aluminumHalogen free XLPECore3-core: brown, black, gre

30 y4-core: blue, brown, black, greyHalogen
y4-core: blue, brown, black, greyHalogen free inner sheathLayer of copper wires and a copper tape: BlackfreeUV-resistant 36 AEMCMK-HF Weight EMC- SCREENED POWER CABLEHalogen free, EMC-screened circular stranded aluminumHalogen free XLPECore3-core: brown, black, grey4-core: blue, brown, black, greyHalogen free inner sheathEMC-screenLaye

31 r of copper wires: BlackfreeUV-resistant
r of copper wires: BlackfreeUV-resistant 37 XCMK-HF Weight POWER CABLEHalogen free circular, solid copper circular, stranded copperHalogen free XLPECore3-core: brown, black, grey4-core: blue, brown, black, greyHalogen free inner sheathLayer of copper wires and a copper tape: BlackfreeUV-resistant 38 EMCMK-HF Weight EMC- SCREENED POWER

32 CABLEHalogen free, EMC-screened circula
CABLEHalogen free, EMC-screened circular, solid copper circular, stranded copperHalogen free XLPECore3-core: brown, black, grey4-core: blue, brown, black, grey: HalogenfreeEMC-screenLayer of copper wires: BlackfreeUV-resistant 39 SFS 2755 Applicable parts Weight Halogen free, ScreenedCircular, solid copper, diameter 0,8 mmHaloge

33 n free polyolene Core2-core: blue,
n free polyolene Core2-core: blue, yellow 4-core: blue, yellow, white, red : Insulatedcoresarecreen Halogen free lling sheathfree,UV-resistantgrey soil nor directly in cast concrete. For signaling and control system 40 EN 50288-7 Applicable parts INSTRUMENTATION CABLEHalogen free, pair screened, EMC-screened, armoured Wei

34 ght propertiesStranded, circular, tinned
ght propertiesStranded, circular, tinned copper Halogen free polyolen, colours in the pair: blue and red Cores are twisted to pairs with an earth air earth wireStranded circular, tinned copper 0,5 mm²air screen Polyester-aluminium tape, sequential pair Pairs are twisted togetherEMC-screen Two layers of polyester-aluminium tap

35 e, aluminium sides against each other, a
e, aluminium sides against each other, an earth conductor of circular, stranded, tinned cop Halogen free polyolenefree,UV-resistant not to be laid in soil nor directly in cast concrete. For data transmission in automation, instrumentation and process control systems 41 REDAK-HFINSTRUMENTATION CABLEHalogen free, Screened REDAKWe

36 ight Stranded, circular, tinned copper
ight Stranded, circular, tinned copper Halogen free polyolene, colours in the pair: Cores are twisted to pairs Pairs are twisted together, Two pair cable has made as a quad, where the opposite cores creen Polyester aluminium tape, earth conductor, circular, stranded, tinned copper 0,5 mm²Halogen free lling sheath: Greyfre

37 e,UV-resistant not to be laid directly
e,UV-resistant not to be laid directly in soil nor in cast concrete. For data transmission in automation, instrumentation and process control systems 42 INSTRUMENTATION CABLEHalogen free, pair screened, EMC-screened Weight EMC propertiesStranded, circular, tinned copper Halogen free polyolen, colours in the pair: blue and red

38 Cores are twisted to pairs with an ear
Cores are twisted to pairs with an earth conair earth wire Stranded circular, tinned copper 0,5 mm²air screen Polyester-aluminium tape, sequential pair Pairs are twisted togetherEMC-screen Two layers of polyester-aluminium tape, aluminium sides against each other, an earth conductor of circular, stranded, tinned Halogen free 

39 ;lling sheath: Greyfree,UV-resistant no
;lling sheath: Greyfree,UV-resistant not to be laid directly in soil nor in cast concrete. For data transmission in automation, instrumentation and process control systems 43 44 AXMK PoweRex Weight POWER CABLE 1x300 mm circular stranded aluminum circular stranded aluminum : UV-resistantCore1-core: black4-core: green/yellow, brown,

40 black, grey5-core: green/yellow, blue, b
black, grey5-core: green/yellow, blue, brown, black, grey: UV-resistant 45 PLOUGHABLE POWER CABLE Weight circular stranded aluminum : UV-resistantCoreGreen/yellow, brown, black, grey: UV-resistantFor xed installation into the ground AXMK/PE PoweRex PE 46 AXCMK-W PoweRex Weight PLOUGHABLE POWER CABLECoreBrown, black, greyLayer

41 of copper wires and a copper tape appli
of copper wires and a copper tape applied above metallic screen in order to ensure longitudinally watertight screen area outer sheath, as a radial water barrier. Black weatherproof PE ders, in conduits and cable ducts. Suitable for PoweRex 47 AMCMK-PE PoweRexkV,603-3F, Weight PLOUGHABLE POWER CABLE: PVCCoreBrown, black, greyLayer

42 of copper wires and a copper tape BlackB
of copper wires and a copper tape BlackBlack weatherproof PE PoweRex 48 BS 7629-1 Applicable parts Fire resistant, Halogen free Weight Fire class F4A Fire resistant Self extinguishing and ame retardant Halogen free, low corrosivity of the comCircular, solid copper 1,0 mmCore2-Core: blue, brown4-Core: blue, brown, black, grey

43 creenPolyester-aluminium tape and circul
creenPolyester-aluminium tape and circular, solid, tinned copper 1,0 mm² as a ground conductorfreeUV-resistantcolour red not to be laid in soil nor directly in cast concrete. When circuit integrity is required in case of re. Core insulation must be protecteddirectUV- 49 Weight Fire resistant, Halogen freeINSTALLATION CABLEFire

44 class F4A -1, -2, EN 50200 Fire resistan
class F4A -1, -2, EN 50200 Fire resistant Self extinguishing and ame retardant Halogen free, low corrosivity of the combus Circular, solid copper, Circular, stranded copperCore2-core: blue, brown3-core: green/yellow,blue,brown5-core: green/yellow,blue, brown, black, greyHalogen free lling sheath: HalogenfreeUV-resistantred

45 to be laid in soil nor directly in cas
to be laid in soil nor directly in cast concrete. When circuit integrity is required in case of re Core insulation must be protected against directUV-light 50 HD 627 7D-1 Applicable parts Fire resistant, Halogen free Weight Fire class F4A Fire resistant Self extinguishing and ame retardant Halogen free, low corrosivity

46 of the comCircular, solid copperCore ide
of the comCircular, solid copperCore identicationHalogen free lling sheathfreeUV-resistantcolour red doors, not to be laid in soil nor directly in cast concrete. When circuit integrity is required in case of re 51 Fire resistant, Halogen free, EMC-screenedPOWER CABLE Weight Fire class F4A Fire resistant Self extinguis

47 hing and ame retardant Halogen fr
hing and ame retardant Halogen free, low corrosivity of the com circular, solid copper circular, stranded copper Core identicationBlue, brown, black, greyHalogen free lling sheathEMC-screenLayer of copper wiresfreeUV-resistantcolour red doors, not to be laid in soil nor directly in cast concrete. When circuit integri

48 ty is required in case of re 52 AHX
ty is required in case of re 52 AHXAMK-WSFS 5636, HD 620-10F MEDIUM VOLTAGE CABLE Weight Watertight, circular, stranded and comConductor screenInsulation screenWatertightness Metallic screen Black weatherproof PECircular stranded copper conductorTwisting Three sheathed phase conductors 53 Longitudinally and radially watert

49 ight Watertight, circular, stranded an
ight Watertight, circular, stranded and comConductor screenInsulation screenWatertightness Metallic screen Black weatherproof PESheathed galvanized steel ropeTwisting Three sheathed phase conductors laid-up for ground-, aerial- or water (inland lakes) MEDIUM VOLTAGE CABLE Weight 54 MEDIUM VOLTAGE CABLE Weight Watertight, cir

50 cular, stranded and Conductor screenInsu
cular, stranded and Conductor screenInsulation screenWatertightness Metallic screen Black weatherproof PE Three sheathed phase cores laid-up 55 MEDIUM VOLTAGE CABLE Weight Watertight, circular, stranded and comConductor screen Insulation screenMetallic screen Layer of copper wires with a copper tape Black 56 MEDIUM VOLTAGE

51 CABLE Weight Watertight, circular, st
CABLE Weight Watertight, circular, stranded and comConductor screenInsulation screenMetallic screen Layer of copper wires with a copper tape Black weatherproof PE 57 MEDIUM VOLTAGE CABLE Weight Watertight, circular, stranded and comConductor screenInsulation screenThree insulated conductors are laid up Concentric screen Layer

52 of copper wires with a copper tape wr
of copper wires with a copper tape wrapped around the metallic screen and Black weatherproof PE buried directly in soil. Cable is both longitudinally and radially watertight and therefore suitable for extremely wet conditions. 58 MEDIUM VOLTAGE CABLE Weight Watertight, circular, stranded and comConductor screenInsulation screen

53 Concentric screenLayer of copper wiresMe
Concentric screenLayer of copper wiresMetallic screen screenBlack weatherproof PETwisting Three sheathed phase conductors laid-up buried directly in soil. Cable is both longitudinally and radially watertight and therefore suitable for extremely wet conditions. 59 MEDIUM VOLTAGE CABLE Weight Watertight, circular, stranded and c

54 omConductor screenInsulation screenThree
omConductor screenInsulation screenThree insulated conductors are laid up Metallic screen Aluminium wires laid symmetrically along wrapped around the metallic screen and bonded to the sheath. Two peeling Black weatherproof PE and radially watertight and therefore suitable for extremely wet conditions. Not 60 MEDIUM VOLTAGE CABLE

55 Weight Watertight, circular, stranded an
Weight Watertight, circular, stranded and comConductor screenInsulation screenThree insulated conductors are laid up Metallic screen Aluminium wires laid symmetrically along wrapped around the metallic screen and bonded to the sheath. Two peeling strings Black weatherproof PE ied in soil. Cable is both longitudinally and radially

56 watertight and therefore suitable for ex
watertight and therefore suitable for extremely wet conditions. Not for deep 61 MEDIUM VOLTAGE CABLE Weight Watertight, circular, stranded and comConductor screenInsulation screen applied under metallic screen in order to ensure longitudinally watertight screen areaMetallic screenLayer of copper wires acts as a part of the metall

57 ic screenWeatherproof PE with black cond
ic screenWeatherproof PE with black conductive Three sheathed phase cores laid-up 62 MEDIUM VOLTAGE CABLE Weight Watertight, circular, stranded and comConductor screen Insulation screen applied under metallic screen in order to ensure longitudinally watertight screen areaMetallic screenLayer of copper wires acts as a part of the

58 metallic screenWeatherproof PE with blac
metallic screenWeatherproof PE with black conductive Three sheathed phase cores laid-up 63 Circular stranded copperConductor screenInsulation screenMetallic screen Layer of copper wires with a copper tape BlackMEDIUM VOLTAGE CABLE Weight 64 Reka Cables Ltd. manufactures high quality one core high requirementsCENELEC HD 632 and S

59 FS 5702 standards. Customer’s speci
FS 5702 standards. Customer’s special demands are also possible to take into account. We can deliver both aluminium- and copper high voltage ca copper. 26/45 Circular, stranded and compacted aluConductor screenInsulation screenWatertightness Longitudinal and radial waterproong is Metallic screen Layer of copper wires with

60 a copper tape The metallic screen can a
a copper tape The metallic screen can also be compleUV-protectedHIGH VOLTAGE CABLES 45 - 150 kV 65 Circular, stranded copper Earthing conductor and electrode Weight 66 CORE IDENTIFICATION BU BN GNYE BU BN BK GNYE BN BK GY GY BK only 1,5 and 2,5 mm2N-Tand cables with concentric conductor BU BN BU BN BKBUBN GY BK BK Without N-

61 or S-marking GY BK GY 67 BENDING RADI
or S-marking GY BK GY 67 BENDING RADII AND PULLING FORCES TALLATIMK-HF, MKEM-HFTALLATITRUMENTATIKLM-HF, KLMA-HFAXMK 1 coreLTAGELTAGEAHXAMK-W, -WM, -WP Maximum allowed pulling force when pulling from conductors, Maximum allowed pulling force when pulling with cable stocking, The sum of the inner conductor cross-sectional areas. 68

62 TEMPERATURESLowest allowed handling tem
TEMPERATURESLowest allowed handling temperature Maximum allowed continuous operating temperature hort-circuit: Maximum allowed conductor temperature in short-circuit, ERATINGRT-TALLATIMK-HF, MKEM-HFTALLATITRUMENTATIcoreAXCMK-HF, AXCMK-WLTAGEAHXAMK-W, -WM, -WP 69 DRUMS AND THE DRUM CAPACITIES Ø mmK4K5K6K7K8K9K10K11K123258141725

63 3140553,5146101218222940413479131722314,
3140553,5146101218222940413479131722314,51236711131724589923568111419662412346710137456112345710833682411234579275631947112345102255397541122341117839963911122412 3324908051112313 311407689930112214 391579796111215 32755969091111216 27847259079011117 3924967589281118 3724716467961119 312401541759921120 305392530659879121 2

64 39314451624739122 30544053372493723
39314451624739122 30544053372493723 24741151961989724 23934143560476225 24234542250674726 28040949271027 27033347758928 25932139057429 30937656030 31236254531 24634843832 23528942533 23727741134 27941435 26640036 26830937 25529738 20429939 287 40

65 28841 27642 27843
28841 27642 27843 20244 20345 193 Flange diameter mm, DInner widht, LOuter widht, mmTransp.vol. m³ without boardTransp.vol. m³ with boardEmpty weight, kg 70 DRUMS AND THE DRUM CAPACITIES Ø mmK14K16K18K20K22K24K26K28K30373941181531982663855557593,5536986113145195283404556441536686111150216310426

66 4,53241526887117170245335526344355719613
4,53241526887117170245335526344355719613920027361823293749669613818871316212836487010013881013162127375377105971013172129426183106810131724345068115781114192840551245791216243446133467101320283914345781217243415234571015222916234569131925172234571116231812345710152019122346913182012234681216211123357111422112234691323111234681224111223

67 5811259851122357102693511123569277911112
5811259851122357102693511123569277911112346828772111234682975299211224573073183711123573160481311123563258578811123463356776285711234634570653862111245354576308321112353644060880292111234374245856579251123438426488661895112343940946863486411234 40411471637868112234131645161069911123423174535096738561123433034324866758601123443044354886

68 4882611234529033246565182911234629133346
48826112345290332465651829112346291333467624795112347292335469506798937122482783184454846368961124921331935948563890011250214320360487641904112 Flange diameter mm, DInner widht, LOuter widht, mmTransp.vol. m³ without boardTransp.vol. m³ with boardEmpty weight, kg 71 DRUMS AND THE DRUM CAPACITIES Ø mmK14K16K18K20K22K24K26K28K305120

69 2303340464611863112522033043424656138671
2303340464611863112522033043424656138671125320330534344258370111254 22032344458570311255 22032444558770611256 22132542244867011157 20730432645067211158 2083063274516759871159 2092353094266388411160 2092363094276408441161 1952193104285328051162 1962203114305348081163 1962212924045028111164 2212934055047711165 2222944065067731166 2062

70 954075087761167 2062762934757361168 20
954075087761167 2062762934757361168 207276294477611976169 207277295478613979170 208278295480615983171 191200296386581987172 192186276359582793173 137186276360584796174 186277361586798175 187278362588801176 187278363553759177 173257336554762178 173258337556765179 17425933844676796480 17425933944772496881 174260340

71 41972797182 17526034142060097583 175
41972797182 17526034142060097583 17518634242160297884 16117131442260478085 16117124042356878386 16117224139457078587 17224239557178888 17224239657379189 173243397575747 90 17324339857774991 15822239954075292 15822240054175493 15822337054375694 37154471195 28354671496 28443558797 285405

72 58898 28540659099 286407592100
58898 28540659099 286407592100 286408593 Flange diameter mm, DInner widht, LOuter widht, mmTransp.vol. m³ without boardTransp.vol. m³ with boardEmpty weight, kg 72 CPR REACTION TO FIRE REQUIREMENTS EN 50575Classes according to TestEN 50399 (30 kW ame source)and Smoke production (and Flaming droplets/) and Acidity

73 EN 50399 (20,5 kW ame source)Smoke
EN 50399 (20,5 kW ame source)Smoke production (and Flaming droplets/EN 50399 (20,5 kW ame source) 60 kW; Smoke production (2,6) and Flaming droplets/EN 50399 (20,5 kW ame source) 400 kW; Smoke production (2,6) and Flaming droplets/LANATIIATIgross caloric potential [MJ/kg] vertical ame spread [mm] equals the

74 damaged length of the sample total heat
damaged length of the sample total heat release (HRRsm30) from test start until end of test, excludedcontribution from ignition source [MJ] maximum heat release rate (HRRsm30) between test start and end of test, excluding contribution from ignition source [kW] re growth rate index used for classication purposes vertical &

75 #31;ame spread [m] as dened in EN 6
#31;ame spread [m] as dened in EN 60332-1-2s1 the cable can release a very limited amount of smokes2 the cable can release limited amount of smokes3 there are no requirements for releasing of smoke, but it shall be testedd0 the cable can't release any aming droplets at alld1 the cable can release a limited amount of amin

76 g dropletsd2 there are no requirements f
g dropletsd2 there are no requirements for releasing aming droplets, but it shall be tested.a1 the cable can release a very limited amount of acid and corrosive gasesa2 the cable can release limited amount of acid and corrosive gasesa3 there are no requirements for releasing acid and corrosive gases, but it shall be 73 74 OTES 7