Download Presentation The PPT/PDF document "Containment" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
Slide1
ContainmentSolutionsSlide2
Cooling Efficiency Solutions
Passive Thermal Containment
Blanking Panels
Foam, Skirts and Covers Raised Floor Grommets Brush Seal Solutions Under-Floor Baffle System Containment Curtains, Panels and Doors Capped Aisles Dynamic Airflow Management In-Rack Airflow Delivery and Distribution Under-Floor and Overhead Air Movers Intelligent Airflow Distribution and Management Pressure-Managed Heat Extraction Slide3
Cooling Efficiency SolutionsPassive Thermal Containment
Aid data center airflow and cooling
Prevents by-pass airflow and mixing
Considered “Best Practices” productsHigh Value for lower costTypically used in conjunction with larger efficiency initiativesCan be part of Utility Incentive projectsContainment Solutions typically require design and are custom to each application. Applies to HAC and CACCRAC Duct and Extender Kits
Modular Design, easy to assemble, non-intrusive to drop ceiling, access door for filters. Ships flat, assembles on-site
Blanking Panels
Foam, Skirts and Covers
Raised Floor Grommets Brush Seal Solutions Under-Floor Baffle System Containment Curtains, Panels and Doors Capped AislesSlide4
Cooling Efficiency SolutionsDynamic Airflow Management
In-Rack Airflow Delivery
and Distribution
Under-Floor and OverheadAir Movers Intelligent Airflow Distribution
and Management
Pressure-Managed Heat Extraction Slide5
Containment Solutions Hot and Cold AislesDesign Capabilities
Aisle end showing door design where racks do not line up with one another
Vertical Panels with twin-wall inserts used
for gaps in rows, irregular alignment, and above racksDrop-Away Panels installed on tops of racks to cap the aisleSlide6
Containment Solutions for Hot and Cold AislesDesign Capabilities
Vertical Panel creates barrier for empty rack location
Vertical Panel to even out aisle endSlide7
Containment Solutions for Hot and Cold AislesFinished SolutionSlide8
Containment Solutions for Hot and Cold AislesAisle End Swing Doors
Detail of Swing Door mounting
Attachment to
row-end racksSlide9
Containment Solutions for Hot and Cold AislesCustom Swing Doors
Low-Profile Aisle End Swing Doors installed in gap between PDU and rackSlide10
Containment Solutions for Hot and Cold AislesAisle End Sliding Doors
Sliding Door attached to row-end racksSlide11
Containment Solutions for Hot and Cold AislesAisle End Sliding DoorsSlide12
Containment Solutions for Hot and Cold Aisles Vertical and Custom Panels
Vertical Panels Installed in contained aisle
along with Single-Wide DoorSlide13
Containment Solutions for Hot and Cold AislesVertical and Custom Panels
Free-Standing Vertical Panel with feetSlide14
Containment Solutions for Hot and Cold AislesCapped Aisles
Overhead photo of “Drop-Away” Panels in custom framesSlide15
Containment Solutions for Hot and Cold Aisles Capped Aisles
“Drop-Away” Panels and Single Sliding DoorSlide16
Containment Solutions for Hot and Cold AislesCRAC/CRAH Hoods
DCIM CRAC Hood used to direct-couple to overhead plenum Slide17
Containment Solutions for Hot and Cold AislesCRAC/CRAH Hoods
Custom Duct DesignsSlide18
Containment Solutions for Hot and Cold Aisles CRAC/CRAH Hoods
Filter Access DoorSlide19
Containment SolutionsCapabilities
Thermal/Capacity Assessments
CFD Modeling
Containment DesignStandard and Custom ProductsMonitoring and AlertingFabricationTurnkey Installation and Logistics