/
letter symbol 148A148 select     modules preselect    SELECT stand by letter symbol 148A148 select     modules preselect    SELECT stand by

letter symbol 148A148 select modules preselect SELECT stand by - PDF document

brooke
brooke . @brooke
Follow
343 views
Uploaded On 2021-08-12

letter symbol 148A148 select modules preselect SELECT stand by - PPT Presentation

Siemens Page 1 of 4 Siemens last status reached by autom autom XB85 ZEA no status discrepancy discrep XB86 NOSD no running timetorque alarm runnung t XB87 KLB typ communication DCM ID: 862556

load rotation breaker signal rotation load signal breaker output side drive status open counterclockwise clockwise reversing typ fault voltage

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "letter symbol 148A148 select modules..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 Siemens letter symbol ”A” se
Siemens letter symbol ”A” select modules preselect SELECT stand by unit start--up ASO Page 1 of 4 Siemens last status reached by autom. autom. XB85 ZEA no status discrepancy discrep. XB86 NOSD no running time/torque alarm runnung t. XB87 KLB typ communication DCM typ comm. XB95 OMControlling letter symbol ”C” select modules drive control module DCM continuous controller module CC operation--setpoint controller O--SPC text of signal setting signal ea_nam actual status open open XC01 CB/OPEN actual status closed closed XC02 CB/CLOSED no control drive fault no fault XC05 NO/FAULT actual status controlling autom. XC11 CB/CLC actual status manual/control man. XC12 CB/MAN no fault no fault XC82 KAS last status reached manuel manual XC83 ZEH last status by protection protection XC84 ZES last status reached by autom. autom. XC85 ZEA no status discrepancy discrep. XC86 NOSD no running time/torque

2 alarm runnung t. XC87 KLB typ communi
alarm runnung t. XC87 KLB typ communication O--SPC typ comm. XC90 OM typ communication CCON typ comm. XC93 OM typ communication CC typ comm. XC95 OM Page 2 of 4 Siemens Pin designation Description + minus--connection (for initiators acc. to DIN 19234 (NAMUR)) -- plus--connection (for initiators acc. to DIN 19234 (NAMUR)) ALA output load breaker OFF/CLOSE ALAS output load breaker OFF/CLOSE for actuator/control drive ALE output load breaker ON/OPEN ALES output load breaker ON/OPEN for actuator/control drive ALK output load breaker check command ALKS output load breaker check command for actuator ALL output load breaker counterclockwise rotation ALLA output load breaker counterclockwise rotation OFF ALLE output load breaker counterclockwise rotation ON ALLK output load breaker check command counterclockwise rotation ALR output load breaker clockwise rotation ALRA output load breaker clockwise rotation OFF ALRE output load breaker clockwise rotation ON ALRK

3 output load breaker check command clock
output load breaker check command clockwise rotation ALS output load breaker STOP ANB feeder not ready ANBL feeder not ready for counterclockwise rotation (reversing drive) ANBR feeder not ready for clockwise rotation (reversing drive) C common (changeover, single contact) DEAUF torque switch OPEN DENAUF torque switch NOT OPEN DENZU torque switch CLOSE DEZU torque switch NOT CLOSE I+ current signal from transducer (plus side) I- current signal from transducer (minus side) IY+ manipulated variable (current plus side) KV contact power supply, general L auxiliary supply L+ supply voltage for e.g. +24 supply L+MU auxiliary supply for two-re transducers M ground, reference voltage (--) MTU motor temperature -- monitor response NC normally closed contact NO normally open contact NOT EMERGENCY OFF PAR Signal for modules connected in parallel RI+ RTD constant current (plus side) RI-- RTD constant current (minus side) RMA checkback signal OFF/CLOSE RME checkbac

4 k signal ON/OPEN RML checkback signal,
k signal ON/OPEN RML checkback signal, counterclockwise rotation (reversing drive) RMNA checkback signal NOT OFF/CLOSE RMNE checkback signal NOT ON/OPEN RMNL checkback signal, NOT counterclockwise rotation (reversing drive) RMNR checkback signal, NOT clockwise rotation (reversing drive) RMR checkback signal, clockwise rotation (reversing drive) RU+ RTD measuring voltage (plus side) RU-- RTD measuring voltage (minus side) SAG switchgear fault SAGL switchgear fault, counterclockwise rotation (reversing drive)SAGR switchgear fault, clockwise rotation (reversing drive) SIG non--floating binary signal Page 3 of 4 Pin designation Description TU+ thermocouple measuring voltage (plus side) TU- thermocouple measuring voltage (minus side) U+ measuring voltage (plus side) U- measuring voltage (minus side) UGS undervoltage limit signal VOS local control YN+ follow--up value for the manipulated variable (plus side) YN- follow--up value for the manipulated variable (minus si