Victaulic Series 731-D Suction Diffuser provides optimum flow conditio Victaulic Series 731-D Suction Diffuser provides optimum flow conditio

Victaulic Series 731-D Suction Diffuser provides optimum flow conditio - PDF document

conchita-marotz
conchita-marotz . @conchita-marotz
Follow
516 views
Uploaded On 2015-11-06

Victaulic Series 731-D Suction Diffuser provides optimum flow conditio - PPT Presentation

WARNINGAlways depressurize and drain system before disassembly Failure to do so could result in serious personal injury property damage joint leakage or joint separationWARNING Housing body cou ID: 184604

WARNINGAlways depressurize and drain

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "Victaulic Series 731-D Suction Diffuser ..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

victaulic.com09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved. 1.0PRODUCT DESCRIPTIONAvailable Sizes to 12 x 12/DN80 x DN50 to DN300 x DN300 1 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Victaulic Suction DiffuserSeries 731-D 09.20 System No.LocationSubmitted ByDate Spec SectionParagraphApprovedDate 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 3.0SPECIFICATIONS – MATERIALHousing (Body, Coupling, End Cap): Ductile iron conforming to ASTM A395.Housing Coating: (specify choice)Standard: Orange enamel.Optional: Hot dipped galvanized.Coupling Gasket: (specify choice)Victaulic EPDM(Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. UL Classied in accordance with ANSI/ NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT RECOMMENDED FOR PETROLEUM SERVICES.Victaulic Nitrile(Orange color code). Temperature range +10°F to +150°F/–12°C to +65°C. Not compatible for hot water services over +150°F/+66°C or for hot dry air over +140°F/60°C. NOT RECOMMENDED FOR HOT WATER SERVICES.Diffuser: Type 304 stainless steel, frame and perforated sheet with "/4 mm diameter holes.Start-Up Pre-Filter: 20 mesh stainless steel, Type 304. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A449 and physical requirements of ASTM A183.Support: Boss for support. See table below for size. (Support not supplied.) 2 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.0DIMENSIONSANSI Dimensions Series 731-D with ANSI Class 150 Flange SERIES D L1 H1 H2 L½ E 3 – 12"/80 – 300 mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size 15.55395150.668.3150822.5058412.4031511.002796.801721.25-11.5 NPT15.55395159.972.52001022.5058412.4031511.002798.072051.25-11.5 NPT15.55395172.078.025012300x827.0068615.4339213.193356.751721.25-11.5 NPT18.58472245.42001026.8468615.4339213.193358.072051.25-11.5 NPT18.58472260.32501226.8468615.4339213.193359.502411.25-11.5 NPT18.58472273.2300 3 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.1DIMENSIONSDIN Dimensions Series 731-D with PN10/PN16 Flange SERIES D L1 H1 H2 L½ E 80 – 300 mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size 16.002299.002038.001305.101.25-11 ISO 7-127911.0030.0515040616.002299.002038.001445.701.25-11 ISO 7-127911.0031.962008x139.7 mm48319.0026010.202299.001305.101.25-11 ISO 7-131812.5044.712548319.0026010.202299.001305.101.25-11 ISO 7-131812.5044.7515048319.0026010.202299.001445.701.25-11 ISO 7-131812.5046.3102.1620048319.0026010.202299.001726.801.25-11 ISO 7-131812.5050.2110.78 4 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.1DIMENSIONS (Continued)DIN Dimensions Series 731-D with PN10/PN16 Flange SERIES D L1 H1 H2 L½ E 80 – 300 mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size 5 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.2DIMENSIONSGB Dimensions Series 731-D with GB Flange SERIES D L1 H1 H2 L½ E 76.1 – 300 mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size 19.0026010.22299.001305.101.25-11 ISO 7-131812.5044.7515048319.0026010.22299.001445.701.25-11 ISO 7-131812.5046.3102.1620048319.0026010.22299.001726.801.25-11 ISO 7-131812.5050.2110.78 6 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.2DIMENSIONS (Continued)GB Dimensions Series 731-D with GB Flange SERIES D L1 H1 H2 L½ E 76.1 – 300 mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size 7 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.3DIMENSIONSJIS Dimensions Series 731-D with JIS 10K Flange SERIES D L1 H1 H2 L½ E 350A – 600A mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size 8x139.7 mm48319.0026010.202299.001305.101.25-11 ISO 7-131812.5044.798.5125A48319.0026010.202299.001305.101.25-11 ISO 7-131812.5044.798.55150A48319.0026010.202299.001445.701.25-11 ISO 7-131812.5046.3102.16200A48319.0026010.202299.001726.801.25-11 ISO 7-131812.5050.2110.78 8 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.3DIMENSIONS (Continued)JIS Dimensions Series 731-D with JIS 10K Flange SERIES D L1 H1 H2 L½ E 350A – 600A mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size 9 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.4DIMENSIONSAS Dimensions Series 731-D with Australian Standard Flange Table “E” SERIES D L1 H1 H2 L½ E 3 – 12"/80 – 300 mm SizeDimensions Approx.Weight (Each)SystemSideGroovedPump Side Flange ANSI Class 150Nominal SizeThread Size Available with No. 50 Concentric Reducer and the appropriate coupling for additional size needs. Contact Victaulic for details. 10 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.5DIMENSIONSSupport and tap boss location Series 731-D Suction Diffuser A C F Support B DE Inlet SizeBoss TapTwo Places Support LocationsThree Places Listed as diameters. 11 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.6DIMENSIONSAssembly Clearance The recommended access requirements and support leg pipe diameters are listed in the following table. The recommended support leg in pipe diameters is based on Schedule 40 pipe. Reference the illustration on the next page. Recommended Mininmum Clearance Required to Remove Diffuser BasketANSIDINSizeClearance"C"Rec.SupportLeg PipeSizeClearance"C"Rec.SupportLeg PipeSizeClearance"C"Rec.SupportLeg PipeDiameterDiameterDiameter Based on Schedule 40 pipe diameter. 12 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 4.6DIMENSIONS (Continued)Assembly Clearance Recommended Mininmum Clearance Required to Remove Diffuser BasketJISAS Table "E"SizeClearance"C"Rec.SupportLeg PipeSizeClearance"C"Rec.SupportLeg PipeDiameterDiameter Based on Schedule 40 pipe diameter. C 13 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 5.0PERFORMANCEFlow CharacteristicsFormulas for C Values: Formulas for K Values:     Where:\r\f\f \r\n \t\t\f\b \r\b\r Q = Flow (m3/hr)P = Pressure Dr op (Bar) K v values for ow of water at +60°F/+16°C through a fully open valve. SizeActual Outside DiameterFlow Data 14 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 5.0PERFORMANCE (Continued)Flow Characteristics 1 0.11010100100010000 Flow Rate – GPMFriction Loss - psi A B D E H G F I L M N O P Q R S 11010010100100010000 A B D E H J G F I L M N O P Q R Flow Rate - LPMFriction Loss – kPa 15 victaulic.com 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 6.0NOTIFICATIONS WARNINGAlways depressurize and drain system before disassembly. Failure to do so could result in serious personal injury, property damage, joint leakage or joint separation.7.0REFERENCE MATERIALS05.01: Victaulic Seal Selection Guide24.01: Victaulic Pipe Preparation ToolsI-100: Victaulic Field Installation Handbook 16 victaulic.com User Responsibility for Product Selection and SuitabilityEach user bears nal responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer.Intellectual Property RightsNo statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or afliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries.NoteThis product shall be manufactured by Victaulic or to Victaulic specications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specications, designs and standard equipment without notice and without incurring obligations.InstallationReference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com.WarrantyRefer to the Warranty section of the current Price List or contact Victaulic for details.TrademarksVictaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its afliated entities, in the U.S. and/or other countries. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Victaulic Suction DiffuserSeries 731-D 09.20 09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved.victaulic.com 3.0 SPECIFICATIONS – MATERIALHousing (Body, Coupling, End Cap): Ductile iron conforming to ASTM A395.Housing Coating: (specify choice)Standard: Orange enamel.Optional: Hot dipped galvanized.Coupling Gasket: (specify choice) Victaulic EPDM(Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. UL Classied in accordance with ANSI/ NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT RECOMMENDED FOR PETROLEUM SERVICES. Victaulic Nitrile(Orange color code). Temperature range +10°F to +150°F/–12°C to +65°C. Not compatible for hot water services over +150°F/+66°C or for hot dry air over +140°F/60°C. NOT RECOMMENDED FOR HOT WATER SERVICES.Diffuser: Type 304 stainless steel, frame and perforated sheet with "/4 mm diameter holes.Start-Up Pre-Filter: 20 mesh stainless steel, Type 304. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A449 and physical requirements of ASTM A183.Support: Boss for support. See table below for size. (Support not supplied.) 2 victaulic.com victaulic.com09.20 5499 Rev E Updated 04/2017 © 2017 Victaulic Company. All rights reserved. 1.0 PRODUCT DESCRIPTIONAvailable Sizes to 12 x 12/DN80 x DN50 to DN300 x DN300Pressure ClassRated to the working pressure of the mating ange up to a maximum of 365 psi/2517 kPa/25 bar. ApplicationProvides optimum ow conditions at the inlet side of the pump.Removable basket and ne mesh sleeve act as start-up strainer. Pressure port in the cap measures pressure downstream of the diffuser.Plug in the cap allows for easy draining of the system2.0 CERTIFICATION/LISTINGSNot applicable – contact Victaulic with any questions. 1 System No.LocationSubmitted ByDate Spec SectionParagraphApprovedDate