/
The anatomy of a housing boom: The The anatomy of a housing boom: The

The anatomy of a housing boom: The - PowerPoint Presentation

ellena-manuel
ellena-manuel . @ellena-manuel
Follow
401 views
Uploaded On 2016-03-06

The anatomy of a housing boom: The - PPT Presentation

Energy Performance Survey of Irish Housing Jeff Colley Editor The Energy Performance Survey of Irish Housing June 2004 SEI goes out to tender SEI invites tenders from suitably qualified organisations or groups for the purposes of carrying out a detailed survey of Irish housing st ID: 244188

housing energy performance irish energy housing irish performance survey report houses amp department tgd compliance seai boilers 2005 regulations

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "The anatomy of a housing boom: The" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

The anatomy of a housing boom: The

Energy Performance Survey of Irish Housing

Jeff Colley EditorSlide2

The Energy Performance Survey of Irish Housing

June 2004: SEI goes out to tender

“SEI invites tenders from suitably qualified organisations or groups for the purposes of carrying out a detailed survey of Irish housing stock to determine both a) levels of compliance with existing regulations governing energy conservation

and b)

actual vs. theoretical energy performance.

The survey will also serve as a pilot demonstration of potential Home Energy Rating methods in the context of SEI’s Home Energy Rating programme

.”

Tender won by

Codema & DIT, working with Cork City, Galway & Tipperary Energy Agencies

January-May 2005: surveying carried out

May 2005: first draft submitted to SEAISlide3

The Energy Performance Survey of Irish Housing

Sample was a “representative cross-section of the existing Irish national housing stock” (age of construction, house type, construction type, geographic spread & tenure of occupancy)

150 houses surveyed in total

52 post-1997 houses checked for compliance against parts F (ventilation), J (heat producing appliances) and L (conservation of fuel and energy) of building regulations, and SI 260 (boiler efficiency)Slide4

The Energy Performance Survey of Irish HousingOf the 52 houses inspected:

no house complied with all 3 parts of buildings regulations;only 1 complied in full with energy efficiency standards under TGD L, but the report claims that 85% of homes are “properly” insulated;

52% complied with TGD J in full; 93% of houses with oil boilers failed section 5 of TGD J – due to “an inadequate base” and “absence of any lack of a barrier”;

29

% of houses did not

comply with section 1 of

TGD J

– CO pollution risk;

58% met ventilation standards under TGD F. In some cases, no background ventilation

was included, & in “a significant number of dwellings (estimated at 35% by one surveyor) the permanent vent is stuffed up with paper or cloth”;

63

% failed on heating

controls;

87

% failed to meet air infiltration

measures;

92

% failed to meet minimum insulation levels for water cylinders, pipes and

ducts;

56

% of boilers

met the

efficiency requirements of SI 260 – 100% of condensing gas boilers, 72% of

non-condensing gas

boilers & 30% of non-condensing oil

boilers;

significant

energy efficiency losses

noted due

to internal dry-lining and dormer roofsSlide5

The Energy Performance Survey of Irish HousingBut the 85

% “properly” insulated claim doesn’t stand upSlide6

The Energy Performance Survey of Irish HousingSlide7

The Energy Performance Survey of Irish HousingSlide8

The Energy Performance Survey of Irish HousingWhy does any of this matter?

It’s the only report analysing compliance with building regulations (apart from a NDA report on compliance with Part M)Data from inspection of 12-15% of new homes hasn’t been collated into a compliance

reportSince SEAI received the 1st draft in May 2005

:

People buying those homes (new or 2

nd

hand) since mid 2005 – many

in

negative equity & challenging accepted definitions of fuel poverty – had a right to know

Would some people have thought twice before buying?

Over 93,000 houses were built in 2006, the last record

year

Priory

Hall was completed (2006

)

Over 270,000 new dwellings have been built (since start of

2006)

Over

780,000 homes built since 1997 – 39% of Ireland's entire

housing stockSlide9

The Energy Performance Survey of Irish HousingWhat should have happened

?Publication of the reportRecommendations should have been acted on for:analysis of a larger sample (450 houses)

more detailed analysis, including thermal comfort thresholds, ventilation, alternative energy systems and domestic hot water systems

 

The Department

of the Environment should have commissioned

a report

on compliance with all parts (A-M) of building regulations

A meaningful building control system, including rigorous site inspections and punitive actions, should have been

introducedSlide10

The Energy Performance Survey of Irish HousingWhat happened to the report

?2005/06

Elements of findings presented at 3 Sebnet meetings & the IBCI & Remic conferences, and papers given at the Solar Cities conference and submitted to the Energy Performance of Buildings Journal

Feb 2007

Construct Ireland and Sunday Tribune articles in Jan/Feb 2007 based on limited

data gleaned from

Sebnet

meetings and interview

Dáil

: Green TDs asked the government to publish the report

Bertie

Ahern: “If

Deputy Sargent is saying 98% of the new houses built in this country are in breach of the existing guidelines, it is not true

. […]

It is another study of ten houses picked by the Deputy himself

.”Slide11

The Energy Performance Survey of Irish HousingDec

2007 Dáil: current housing minister Jan O’Sullivan asked minister Gormley if his department had seen the report. His response: “My department has not received a copy of the draft or final report, although it has been given access to an extract from the executive summary of the report.”Slide12

The Energy Performance Survey of Irish HousingFour years passed….

Slide13
Slide14

The Energy Performance Survey of Irish HousingNov 2011

SEAI to the Irish Examiner: “Given the nature of this particular research, it was not appropriate nor within the remit of the project to convey the findings as suggested."

SEAI to Construct Ireland: “A number of useful studies, not necessarily for publication but often shared with stakeholders, have been commissioned to inform SEAI’s approaches to delivering on its assigned responsibilities, including advice in relation to techno-economic and policy development and implementation matters.”

Department

of the Environment to Construct Ireland: “The department was aware of the findings of this report through interaction with SEAI on a range of issues related to the EPBD and TGD L but as far as we are aware at this time (6 years later) the Department did not have any formal meetings or communications focussed specifically on this report

.”Slide15

The Energy Performance Survey of Irish Housing“Information wants to be free

” – Stuart BrandTo view the report visit bit.ly/seaireportThank you

Jeff ColleyEditor

Ph

: 01 2107513

jeff@constructireland.ie

www.constructireland.ie

Twitter: @

constructirl