GEZE swing door drive PowerturnFully automatic swing door drive for 1 GEZE swing door drive PowerturnFully automatic swing door drive for 1

GEZE swing door drive PowerturnFully automatic swing door drive for 1 - PDF document

hailey
hailey . @hailey
Follow
343 views
Uploaded On 2021-08-17

GEZE swing door drive PowerturnFully automatic swing door drive for 1 - PPT Presentation

62Area of applicationInternal and external doorsRailway stations and airportsHotels and gastronomyHospitals and homes for the elderlyDepartment stores and shopping centresEducational institutions eg s ID: 865366

leaf door powerturn installation door leaf installation powerturn opening hinge swing din safety 18650 16005 side max closing link

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "GEZE swing door drive PowerturnFully aut..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 62 GEZE swing door drive PowerturnFully
62 GEZE swing door drive PowerturnFully automatic swing door drive for 1 and 2-leaf single-action doorsThe new swing door drive Powerturn oers comfort and safety for every access situation. The fully automatic drive is powerful and opens doors with leaf widths of up to 1600 mm or leaf weights of up to 300 kg reliably and safely. It oers freedom to design for a wide range of uses. The unique „Smart swing“ function allow

2 s for easy manual use even of large, hea
s for easy manual use even of large, heavy doors, e.g. re protection doors or façade doors, at any time. The powerful closing spring is once pre-tensioned and does not have to be moved permanently during passage. In addition, the „Smart swing“ function reduces energy costs during operation and in the „permanently open“ position. The small overall height and discreet design make it exible and future-proof for

3 multifunction safety doors, safe escape
multifunction safety doors, safe escape and rescue routes and complex interlocking door systems. This makes the Powerturn an excellent example of „Universal Design - made in Germany“. Installation is straightforward and safe due to the simple GEZE installation system. GEZE Powerturn Area of applicationInternal and external doorsRailway stations and airportsHotels and gastronomyHospitals and homes for the elderlyDepartment store

4 s and shopping centresEducational instit
s and shopping centresEducational institutions, e.g. schools, nursery schools, day care centresLeisure facilities, e.g. baths, thermal baths, sport and wellness centresAdministration and public buildingsFood industryGEZE Powerturn 63 Technical data Product featuresGEZE Powerturn1-leaf / 2-leafGEZE Powerturn FGEZE Powerturn F-ISGEZE Powerturn F/RGEZE Powerturn F/R-ISHeight70 mmWidth720 mmDepth130 mmLeaf weight (max.) 1-leaf300 kgHinge

5 clearance (min.-max.) 2-leaf link arm14
clearance (min.-max.) 2-leaf link arm1480 - 3200 mmHinge clearance (min.-max.) 2-leaf roller guide rail1600 - 3200 mmLeaf width (min.-max.)800 - 1600 mmReveal depth (max.)*-30 - 560 mm0 - 300 mmDrive typeElectromechanicalDoor opening angle (max.)*136 °Spring pre-load**EN4 - EN7DIN leftDIN rightTransom installation opposite hinge side with link armTransom installation opposite hinge side with roller guide railTransom installation hinge s

6 ide with roller guide railDoor leaf inst
ide with roller guide railDoor leaf installation opposite hinge side with roller guide railDoor leaf installation hinge side with roller guide railDoor leaf installation hinge side with link armMechanical latching actionElectrical latching actionElectrical closing sequence controlMechanical closing sequence control***Disconnection from mainsall pole main switch in the driveActivation delay (max.)10 sOperating voltage230 VFrequency of supp

7 ly voltage50 - 60 HzCapacity rating200 W
ly voltage50 - 60 HzCapacity rating200 WPower supply for external consumers (24 V DC)1200 mA per driveTemperature range-15 - 50 °CIP ratingIP 30Operating modesAutomatic, Night, Permanently open, Shop closing, OType of functionFully automaticAutomatic functionLow-Energy functionSmart swing functionKey functionVestibule functionObstruction detectionAutomatic reversingPush & GoadjustableOperationGEZEconnects (PC + Bluetooth), Service t

8 erminal ST 220, Display programme switch
erminal ST 220, Display programme switch DPSParameter settingGEZEconnects (PC + Bluetooth), Service terminal ST 220, Display programme switch DPSApprovalsDIN 18650, EN 16005, DIN 18263-4DIN 18650, EN 16005, DIN 18263-4DIN 18650, EN 16005, DIN 18263-4, Door closing sequence selector tested in accordance with EN 1158DIN 18650, EN 16005, DIN 18263-4DIN 18650, EN 16005, Door closing sequence selector tested in accordance with EN 1158Integrate

9 d smoke switch (R-variant)YESDEPENDING O
d smoke switch (R-variant)YESDEPENDING ON THE TYPE OF INSTALLATION SEE TABLE OVERVIEW OF TORQUES*** = OPTIONAL FOR 2LEAF SYSTEMS AND TRANSOM INSTALLATION OR ONLY FOR THE IS VARIANTSNOTE: THE MAXIMUM POSSIBLE LEAF WEIGHT IN RELATION TO LEAF WIDTH CAN BE FOUND IN THE CHAPTER ON AREAS OF APPLICATION DIAGRAMS! 64 0204060801001201401601802002202402602803003207008009001000110012001300140015001600 X 6s 5s 4s 3s Y Do

10 or width (mm)Door weight (kg)Diagram sho
or width (mm)Door weight (kg)Diagram showing the use of Powerturn with opening times of up to 90° door opening angleArea of applicationNoteThe movement parameters can be set in such a way that the safety requirements for low-energy operation in compliance with DIN 18650 / EN 16005 are met. The drive then moves the swing door at reduced speed. The use of safety sensors to safeguard the system is only necessary in individual cases, taking

11 the user group into account. In automati
the user group into account. In automatic mode, however, the swing area of the door must always be safeguarded with safety sensors. Opening times PowerturnTo ensure the safety requirements in low-energy operation Door weight (kg)1201501802102402708002.73.43.94.34.75.15.55.89003.13.84.44.95.35.86.26.510003.44.24.85.45.96.46.97.311003.84.65.36.06.57.17.58.012004.15.05.86.57.17.78.28.713004.55.56.37.07.78.38.99.514004.85.96.87.68.39.09.610.2

12 15005.16.37.38.18.99.610.310.916005.56.7
15005.16.37.38.18.99.610.310.916005.56.77.88.79.510.311.011.6Leaf width (mm)Illustration of the minimum opening times to be set depending on the door weight and door leaf width for a door opening from 0° to 80° or for a closing movement from 90° to 10° door opening angle.Overview of Powerturn torques To ensure the safety requirements in low-energy operation in accordance with DIN 18650 / EN 16005 1. K-BS-rail 2. K-BGS-rail3. T-BS-rail

13 4. T-BGS-rail5. K-BGS-link arm6. T-BS-li
4. T-BGS-rail5. K-BGS-link arm6. T-BS-link armMinMaxMinMaxMinMaxMinMaxMinMaxMinMaxEN 1154EN ClassClosing torquesNm (Door)100100Maximum opening torque (automatic)Nm (Door)135121143127180*180*Manual opening torque (Operating mode O)Nm (Door)1010* = Restricted according to DIN 18263-4K = Transom installationT = Door leaf installation   BS = Hinge sideBGS = Opposite hi