Page 1of 7 N ational Fire Protection Association Report 5 23 201 3 htt p First Revision No2NFPA 19322013 Section No 613 Excluding A visual inspection shallinclude but not be limited to ID: 173116

Page 1of 7 N ational Fire Protection

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "First Revision No.6-NFPA A Change all re..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

First Revision No.6-NFPA A Change all references to NFPA 1931, 2010edition, to 1931, 2015 edition.Submitter Information Verification Submitter Full Name: Chris FarrellOrganization: National Fire ProtectionAssocSubmittal Date: Tue May 1406:52:07 EDT 2013Committee Statementand Meeting NotesCommittee Statement: Editorial change to reflectlatest editionResponseMessage: Page 1of 7 N ational Fire Protection Association Report 5 / 23 / 201 3 htt p First Revision No.2-NFPA 1932-2013 [ Section No. 6.1.3 [Excluding A visual inspection shallinclude, but not be limited to, the following: (1)Heat sensor labels on metal and fiberglass ladders, andon wood ladders if provided, for a change indicating heatexposure(2)All rungs, forsnugness and tightness(3)All bolts and rivets, for tightness; bolts on woodladders, for snugness and tightness without crushing the wood(4)Welds, for any cracks or apparentdefects(5)Beams andrungs, for cracks, splintering, breaks, gouges, checks, wavy conditions, ordeformation(6)Butt spurs,for excessive wear or other defects(8)Pulleys and associated hardware, for proper operationand condition (9)Roofhooks, for sharpness and proper operation(10)Rungs, for punctures, wavy conditions, worn serrationsin the foot contact areas, serrations worn down to base metal in any location,or deformation(11)Loss of baseBase material, for loss due tocorrosion (12)Ladder slideareas, for galling or absence of wax, if required by themanufacturer(13)Loss of gloss on fiberglassFiberglassand wood ladder beams,for loss of gloss; damage to the varnish finish onwoodground ladders, for damage to thevarnish finish (14)Correct operation of the pawlPawlassemblies, for correct operation (15)Wire rope on 3-and 4-sectionladders,for snugness whenthe ladder is in the bedded position, to ensure proper synchronization ofupper sections during operation(17)Ladders,clean with no buildup of grease, dirt,or grime on the beams (18)The diagonal brace on the base of afolding ladder,fordamage (19)The hingeassembly and locking pin assemblies on a multi- purposemultipurposeladder,for the presence of any visual damageand for theirproperoperation Submitter Information Verification Submitter Full Name: [ Not Specified ]Organization: [ Not Specified ]Submittal Date: Wed May 01 13:43:19 CDT2013Committee Statement and MeetingNotes*Halyards, for fraying orkinking*Labels,present andlegible Page 2of 7 N ational Fire Protection Association Report 5 / 23 / 201 3 htt p CommitteeStatement: Clarification of language andreplacement.ResponseMessage:Committee Notes: Submitted 2013Ingalls6.1.3 (7) Add asterisk and link to A.6.1.3(7).2013IngallsA.6.1.3(16) Annex material should be submitted in a word doc.2013Ingalls6.1.3 Deleted "visual" from lead-in sentence--many entries require more than a visual inspection. Change okay?Reworded several NL entries for consistency. Changes okay?PublicInput No. 4-NFPA 1932-2013 [Section No. 6.1.3 [Excluding anySub-Sections]] PublicInput No. 5-NFPA 1932-2013 [Section No. 6.2.7] PublicInput No. 6-NFPA 1932-2013 [Section No. A.6.2.7] PublicInput No. 7-NFPA 1932-2013 [New Section after6.2.10.1] PublicInput No. 16-NFPA 1932-2013 [Section No. A.6.1.3(15)] Page 3of 7 N ational Fire Protection Association Report 5 / 23 / 201 3 htt p First Revision No.3-NFPA 1932-2013 Extension ladders shall be extended andretracted their entire length with no interference tooperation. Submitter Information Verification Submitter Full Name: [ Not Specified ]Organization: [ Not Specified ]Submittal Date: Wed May 01 14:06:10 CDT2013Committee Statement and MeetingNotesCommitteeStatement: Adding an operational test will assure there wasno damage to the ladder.ResponseMessage:PublicInput No. 10-NFPA 1932-2013 [New Section after7.2.1.5.3] Page 4of 7 N ational Fire Protection Association Report 5 / 23 / 201 3 htt p First Revision No.4-NFPA 1932-2013 Ifthe ladder does not operate and fold properly after a load test, it shall be removed fromservice. Submitter Information Verification Submitter Full Name: [ Not Specified ]Organization: [ Not Specified ]Submittal Date: Wed May 01 14:26:52 CDT2013Committee Statement and MeetingNotesCommitteeStatement: Make sure the ladder operates properly aftertest.ResponseMessage: Page 5of 7 N ational Fire Protection Association Report 5 / 23 / 201 3 htt p First Revision No.5-NFPA 1932-2013 Ifthe ladder does not operate properly after a load test, it fromservice. Submitter Information Verification Submitter Full Name: [ Not Specified ]Organization: [ Not Specified ]Submittal Date: Wed May 01 14:28:44 CDT2013Committee Statement and MeetingNotesCommitteeStatement: Make sure the ladder operates properly aftertest.ResponseMessage:PublicInput No. 15-NFPA 1932-2013 [Section No. 7.4.6.4] Page 6of 7 N ational Fire Protection Association Report 5 / 23 / 201 3 htt p First Revision No.1-NFPA 1932-20A 1932-20B.2Informational References.(Reserved) NFPA 1500, Standardon Fire Department Occupational Safety and Health , 2013edition. Submitter Information Verification Submitter Full Name: [ Not Specified ]Organization: [ Not Specified ]Submittal Date: Wed May 01 13:18:36 CDT2013Committee Statement and MeetingNotesCommitteeStatement: NFPA 1500 section 6.5.11 requires that all groundladders be inspected and service tested in accordance with the applicablerequirements of NFPA 1932, Standard on Use, Maintenance, and ServiceTesting of In-Service Fire Department Ground Ladders. Adding NFPA 1500 toAnnex B will provide a reader or user of NFPA 1932 with the standard thatrequires ground ladders be inspected and service tested Response Message:Committee Notes: Submitted 2013IngallsB.1.1. new entry NFPA 1500 is not referenced in the text of the Annexes. Should this entry move to B.2, Informational References?PublicInput No. 3-NFPA 1932-2013 [New Section after B.1.1] Page 7of 7 N ational Fire Protection Association Report 5 / 23 / 201 3 htt p