01 for details See Victaulic publication 0206 for potable water approvals if applicable Product Description Style 77 couplings are designed with crossribbed construction to provide a component for pressure piping systems The coupling is offered in a ID: 23397 Download Pdf
The A Series paper size chart to the right gives a visual explanation of how the sizes relate to each other for example A5 is half of A4 size paper and A2 is half of A1 size paper Table of Paper Sizes From 4A0 to A10 Size Height x Width mm Height x
Serving Sizes vs. . Portion Sizes. A . serving size. is a unit of measure that describes a recommended amount of a certain food. . A . portion size. is the amount of a food that you . choose. to eat. .
com DEADLINE SERIES DISCOUNT ON ALL PUBLICATION TECHNICAL DATA PAYMENT Within Lagos 5 days to publication Outside Lagos 7 days to publication 5 10 days insertions 25 11 20 days insertions 5 21 50 days insertions 10 Number of Columns Six 6 Full page
brPage 1br Sizes XS XL HalfChest 25cm below armhole 445 475 505 535 Body Length from Hips 64 66 68 70 Sleeve lenght 65 66 67 68
Larger sizes and custom sizes are available for an additional fee All size charts are body measurements Standard Size Char 10 12 14 15 16 18 20 22 24 BUST 33 34 35 36 37 38 39 12 41 41 42 12 45 12 47 12 49 12 51 12 WAIST 25 26 27 28 29 30 31 12 33 3
International sizes S M L XL XXL XXXL Based on the neck band (cm) 37 - 38 39 - 40 41 - 42 43 44 45 - 46 47 - 48 Mens Tshirts sizes International sizes S M L XL Chest size (cm) 87 92 93 - 98 99 -
Paper Sizes. P. lanning process of the document. Size and type of paper. Businesses have three basic sizes:. Letter (standard American size): . 8.5 x 11. ”. Legal (standard American size): 8.5 . x 14.
PLEASE NOTE: please be sure to select it according to your corresponding measurements. BOYS SIZE CHART / inches BURDA EUR SIZE US SIZE HEIGHT BUST/CHEST WAIST HIP/SEAT SIDE LEG LENGTH 176
represent sizes that easily t into our tabloid products Full page1/2 page vertical1/6 page vertical3/4 page vertical1/2 page1/8 page square3/4 page square2/6 page1/8 page horizontal2/3 page square1/3
Many other sizes possible see below 14 38 716 1532 12 1732 2332 78 Aqu57581 se muestran las medidas de mortaja com57594nmente utilizadas Hay muchas otras medidas posibles lea abajo wwwDiabloToolscom Chipper SetUp Con64257guration Guide DD208 STAC
Published bylindy-dunigan
01 for details See Victaulic publication 0206 for potable water approvals if applicable Product Description Style 77 couplings are designed with crossribbed construction to provide a component for pressure piping systems The coupling is offered in a
Download Pdf - The PPT/PDF document "mm sizes mm sizes ApprovalsListings..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
victaulic.com06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. ¾ 12"/DN20 DN300 sizes 14 24"/DN350 DN600 sizes NOTESee publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. 1 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Victaulic Standard Flexible Coupling Style 77 06.04 System No.LocationSubmitted ByDate Spec SectionParagraphApprovedDate 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 3.0MATERIAL SPECIFICATIONSHousing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request.Housing Coating: (specify choice) Standard: Orange enamel.Optional: Hot dipped galvanized and others.Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choiceGrade E EPDMEPDM (Green stripe color code). Temperature range 30ºF to +230ºF/34ºC to +110ºC. May be specied for cold and hot water service within the specied temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classied in accordance with ANSI/NSF 61 for cold +73ºF/+23ºC and hot +180ºF/+82ºC potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES OR STEAM SERVICES.Grade T NitrileNitrile (Orange stripe color code). Temperature range -20ºF to +180ºF/-29ºC to +82ºC. May be specied for petroleum products, air with oil vapors, vegetable and mineral oils within the specied temperature range. Not compatible for hot water services over +150ºF/+66ºC or for hot dry air over +140ºF/+60ºC.OthersFor alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specic gasket service guidelines and for a listing of services which are not compatible.Bolts/Nuts: (specify choice Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, nish Type III (imperial) or Type II (metric). Optional: Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy hex nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. Optional bolts/nuts are available in imperial size only. 2 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 4.0DIMENSIONSStyle 77 X Z Y Z Y X ¾ 12"/DN20 DN300 sizes14 24"/DN350 DN600 sizesSizePipe End SeparationDeection from CenterlineBolt/NutDimensionsWeight NominalActual Outside DiameterAllowablePer Cplg.PipeQty.SizeApprox. (Each)Degreesinches/ft. Allowable Pipe End Separation and Deection gures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These gures are maximums; for design and installation purposes these gures should be reduced by: 50% for ¾ 3 ½"/DN20 DN90; 25% for 4"/DN100 and larger.NOTEMetric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 3 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 4.0DIMENSIONS (CONTINUED)Style 77 X Z Y Z Y X ¾ 12"/DN20 DN300 sizes14 24"/DN350 DN600 sizesSizePipe End SeparationDeection from CenterlineBolt/NutDimensionsWeight NominalActual Outside DiameterAllowablePer Cplg.PipeQty.SizeApprox. (Each)Degreesinches/ft. 0º240.08 721 x 422.38 56925.86 6553.047777.235 Allowable Pipe End Separation and Deection gures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These gures are maximums; for design and installation purposes these gures should be reduced by: 50% for ¾ 3 ½"/DN20 DN90; 25% for 4"/DN100 and larger. Couplings 8, 10, 12"/DN200, DN250, DN300 sizes available to JIS standards. Refer to Victaulic publication 06.17 for details. For 14 72"/DN350 DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03for information on the Style W77 exible AGS coupling.NOTEMetric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 4 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 4.0DIMENSIONS (CONTINUED)Style 77 X Z Y Z Y X ¾ 12"/DN20 DN300 sizes14 24"/DN350 DN600 sizesSizePipe End SeparationDeection from CenterlineBolt/NutDimensionsWeight NominalActual Outside DiameterAllowablePer Cplg.PipeQty.SizeApprox. (Each)Degreesinches/ft. publication 20.03 Allowable Pipe End Separation and Deection gures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These gures are maximums; for design and installation purposes these gures should be reduced by: 50% for ¾ 3 ½"/DN20 DN90; 25% for 4"/DN100 and larger. For 14 72"/DN350 DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03for information on the Style W77 exible AGS coupling.NOTEMetric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 5 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 5.0PERFORMANCEStyle 77SizeWorking PressureEnd LoadNominalActual Outside DiameterMaximumMaximumkPa Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specications. Contact Victaulic for performance on other pipe.NOTEWARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the gures shown. 6 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 5.0PERFORMANCE (CONTINUED)Style 77SizeWorking PressureEnd LoadNominalActual Outside DiameterMaximumMaximumkPa publication 20.03 Couplings 8, 10, 12"/DN200, DN250, DN300 sizes available to JIS standards. Refer to Victaulic publication 06.17 for details. For 14 72"/DN350 DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03for information on the Style W77 exible AGS coupling. Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specications. Contact Victaulic for performance on other pipe.NOTEWARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the gures shown. 7 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com NoteThis product shall be manufactured by Victaulic or to Victaulic specications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specications, designs and standard equipment without notice and without incurring obligations.InstallationReference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com.WarrantyRefer to the Warranty section of the current Price List or contact Victaulic for details.TrademarksVictaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its afliated entities, in the U.S. and/or other countries. 6.0NOTIFICATIONSFor 14 72"/DN350 DN1800 exible roll groove systems, Victaulic recommends Style W77 AGS couplings. For more information, refer to Victaulic publication 20.03 WARNINGVictaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings.Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICEVictaulic RX grooving rolls must be ordered separately. They are identied by a silver color and the designation RX on the front of the roll sets.7.0REFERENCE MATERIALSI-100: Victaulic Field Installation Handbook02.06: Victaulic Potable Water Approvals ANSI/NSF05.01: Victaulic Seal Selection Guide06.15: Victaulic Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe06.17: Victaulic Couplings and Fittings for JIS Pipe10.01: Victaulic Products for Fire Protection Piping Systems - Regulatory Approval17.01: Victaulic Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products17.09: Victaulic Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe20.03: Victaulic AGS Flexible Coupling Style W7725.01: Victaulic Original Groove System (OGS) Groove Specications26.01: Victaulic Design Data26.04: Victaulic Couplings Vibration Attenuation Characteristics29.01: Victaulic Terms and Conditions of SaleI-ENDCAP: Victaulic End Caps Installation Instructions 8 victaulic.com User Responsibility for Product Selection and SuitabilityEach user bears nal responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer.Intellectual Property RightsNo statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or afliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms Patented or Patent Pending refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. User Responsibility for Product Selection and SuitabilityNoteEach user bears nal responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specications, and the applicable building codes and related Victaulic reserves the right to change product specications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations.instructions. Nothing in this or any other document, nor any verbal recommendation, Installationadvice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer.of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rightsin PDF format on our website at www.victaulic.com.No statement contained herein concerning a possible or suggested use of any material, Warrantyproduct, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.under any patent or other intellectual property right of Victaulic or any of its subsidiaries or afliates covering such use or design, or as a recommendation for the use of such Trademarksmaterial, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms Patented or Patent Pending refer to design or utility patents Victaulic Company, and/or its afliated entities, in the U.S. and/or other countries.or patent applications for articles and/or methods of use in the United States and/or other countries. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Victaulic Standard Flexible Coupling Style 77 06.04 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 6.0 NOTIFICATIONSFor 14 72"/DN350 DN1800 exible roll groove systems, Victaulic recommends Style W77 AGS couplings. For more information, refer to Victaulic publication 20.03 WARNINGVictaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings.Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICEVictaulic RX grooving rolls must be ordered separately. They are identied by a silver color and the designation RX on the front of the roll sets. 7.0 REFERENCE MATERIALSI-100: Victaulic Field Installation Handbook02.06: Victaulic Potable Water Approvals ANSI/NSF05.01: Victaulic Seal Selection Guide06.15: Victaulic Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe06.17: Victaulic Couplings and Fittings for JIS Pipe10.01: Victaulic Products for Fire Protection Piping Systems - Regulatory Approval17.01: Victaulic Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products17.09: Victaulic Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe20.03: Victaulic AGS Flexible Coupling Style W7725.01: Victaulic Original Groove System (OGS) Groove Specications26.01: Victaulic Design Data26.04: Victaulic Couplings Vibration Attenuation Characteristics29.01: Victaulic Terms and Conditions of SaleI-ENDCAP: Victaulic End Caps Installation Instructions 8 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 5.0 PERFORMANCE (CONTINUED) Style 77SizeWorking PressureEnd LoadNominalActual Outside DiameterMaximumMaximumkPapublication 20.03 Couplings 8, 10, 12"/DN200, DN250, DN300 sizes available to JIS standards. Refer to Victaulic publication 06.17 for details. For 14 72"/DN350 DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03for information on the Style W77 exible AGS coupling. Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specications. Contact Victaulic for performance on other pipe.NOTEWARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the gures shown. 7 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 5.0 PERFORMANCE Style 77SizeWorking PressureEnd LoadNominalActual Outside DiameterMaximumMaximumkPa Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specications. Contact Victaulic for performance on other pipe.NOTEWARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the gures shown. 6 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 4.0 DIMENSIONS (CONTINUED) Style 77 X Z Y Z Y ¾ 12"/DN20 DN300 sizes14 24"/DN350 DN600 sizes SizePipe End SeparationDeection from CenterlineBolt/NutDimensionsWeight NominalActual Outside DiameterAllowablePer Cplg.DegreesPipeinches/ft. Qty.SizeApprox. (Each)publication 20.03 Allowable Pipe End Separation and Deection gures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These gures are maximums; for design and installation purposes these gures should be reduced by: 50% for ¾ 3 ½"/DN20 DN90; 25% for 4"/DN100 and larger. For 14 72"/DN350 DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03for information on the Style W77 exible AGS coupling.NOTEMetric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 5 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 4.0 DIMENSIONS (CONTINUED) Style 77 X Z Y Z Y ¾ 12"/DN20 DN300 sizes14 24"/DN350 DN600 sizes SizePipe End SeparationDeection from CenterlineBolt/NutDimensionsWeight NominalActual Outside DiameterAllowablePer Cplg.DegreesPipeinches/ft. Qty.SizeApprox. (Each) 16.772 426.000.13 03.20º270.10 921 x 3½19.69 50022.92 5812.92 7456.7 185 DN45018.000 457.200.13 03.20º240.08 721 x 421.56 54825.00 6353.13 8064.1 18.898 480.000.13 03.20º240.08 721 x 422.38 56925.86 6553.04 7777.2 35 Allowable Pipe End Separation and Deection gures show the maximum nominal range of movement available at each joint for standard grooved pipe. Figures for standard cut grooved pipe may be doubled. These gures are maximums; for design and installation purposes these gures should be reduced by: 50% for ¾ 3 ½"/DN20 DN90; 25% for 4"/DN100 and larger. Couplings 8, 10, 12"/DN200, DN250, DN300 sizes available to JIS standards. Refer to Victaulic publication 06.17 for details. For 14 72"/DN350 DN1800 Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Refer to Victaulic publication 20.03for information on the Style W77 exible AGS coupling.NOTEMetric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details.roll 4 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com 4.0 DIMENSIONS Style 77 X Z Y Z Y ¾ 12"/DN20 DN300 sizes14 24"/DN350 DN600 sizes SizePipe End SeparationDeection from CenterlineBolt/NutDimensionsWeight NominalActual Outside DiameterAllowablePer Cplg.PipeQty.SizeApprox. (Each)Degreesinches/ft. Allowable Pipe End Separation and Deection gures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These gures are maximums; for design and installation purposes these gures should be reduced by: 50% for ¾ 3 ½"/DN20 DN90; 25% for 4"/DN100 and larger.NOTEMetric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 3 victaulic.com 06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved.victaulic.com Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request.Housing Coating: (specify choice)Standard:Orangeenamel. Optional: Hot dipped galvanized and others. Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choiceGrade E EPDM EPDM (Green stripe color code). Temperature range 30ºF to +230ºF/34ºC to +110ºC. May be specied for cold and hot water service within the specied temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classied in accordance with ANSI/NSF 61 for cold +73ºF/+23ºC and hot +180ºF/+82ºC potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES OR STEAM SERVICES.Grade T NitrileNitrile (Orange stripe color code). Temperature range -20ºF to +180ºF/-29ºC to +82ºC. May be specied for petroleum products, air with oil vapors, vegetable and mineral oils within the specied temperature range. Not compatible for hot water services over +150ºF/+66ºC or for hot dry air over +140ºF/+60ºC.OthersFor alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specic gasket service guidelines and for a listing of services which are not compatible.Bolts/Nuts: (specify choice Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, nish Type III (imperial) or Type II (metric). Optional: Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy hex nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. Optional bolts/nuts are available in imperial size only. 3.0 MATERIAL SPECIFICATIONS 2 victaulic.com victaulic.com06.04 1469 Rev V Updated 07/2019 © 2019 Victaulic Company. All rights reserved. ¾ 12"/DN20 DN300 sizes 14 24"/DN350 DN600 sizes 1.0 PRODUCT DESCRIPTIONAvailable Sizes¾ 24"/DN20 DN600Maximum Working PressureAccommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 1000 psi/6894 kPa.Working pressure dependent on material, wall thickness and size of pipe.ApplicationJoins standard roll grooved and cut grooved pipe, as well as grooved ttings, valves and accessories. Provides a exible pipe joint which allows for expansion, contraction and deection.Operating temperature dependent upon gasket and/or seal selection - see Section 3.0.Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic OGS groove prole (See section 7.0 for Reference Materials).Pipe MaterialCarbon steel.For use with stainless steel pipe, refer to Victaulic publication 17.09 for pressure ratings and end loads. 2.0 CERTIFICATION/LISTINGS NOTE See publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. 1 System No.LocationSubmitted ByDate Spec SectionParagraphApprovedDate
© 2021 docslides.com Inc.
All rights reserved.