Download Presentation The PPT/PDF document "Monday – VSP Room" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
Slide1
Monday – VSP Roomweekly checks
Visually Check:
Hvac system for leaks & valve settings
Fresh water system for leaks & valve settings
VSP linkage
Autopilot connections
Ventilation fan switch and breaker
Fuel Valves at the fwd tank for leaks & settings
Fuel valves at the transfer pipe for leaks & settingsSlide2
Monday – VSP RoomWeekly Checks
Cycle all valves in the VSP room
Check oil level in the VSP units
Check oil level in the VSP header tanks
Check bilge for water and pump or suction as needed
Check fresh water system for leaks
Check hot water heater for heat
Fill day tanks and check and record fuel level in the fwd
fuel storage tank
Pump out grey water tank as needed
Check hydraulic oil storage tank level – fill as needed
Check and replace lights
Check ventilation fan plenum for water – drain as needed
Check general alarm bell & light
Check phone & intercom # 107
Clean / wipe / wash / service all areas as neededSlide3
Monday - VSP Room
Pump out grey water tank
Cycle the overboard valve located on the starboard side
Pump switch
50 gal. tank
Overboard valveSlide4
Monday – VSP RoomFill day tanksStick and measure main storage tank
Measure sight gauge for the fwd storage tank
Record fuel onboard
Between each colored mark is 1000 gallonsSlide5
Monday – VSP Roomweekly checks
Cycle VSP cooling overboard valves P&S
Cycle HVAC overboard valve starboard side
Cycle grey water overboard valve starboard side
Port Side
VSP coolingSlide6
Monday – VSP Roomweekly checks
HVAC overboard
Grey water overboard
VSP cooling
Starboard SideSlide7
Monday – VSP Roomweekly checks
Check VSP unit oil level P & S
Dipstick location
Replace gently to avoid cross threading
Operating range
Look for signs of water (foam/milk)Slide8
Monday – VSP Roomweekly checks
Tank Fill
Sight gauge
Refill at this Level
Discharge – Oil outSlide9
Monday – VSP Roomweekly checks
Remove / Lift floor plate and check for water
NEVER PUMP OILY WATER OVERBOARD
Start pump and listen for prime – NEVER run dry – use prime valves if necessary
Close all valves when finished
Check under this floor plate
On / Off
VSP Room Valve
Prime valves
Bilge suction under floor plate