Schedule followupforecast 20150817 EDMS 1536236 J Coupard ENMEF 1 2 20150817 EDMS 1536236 J Coupard ENMEF 50 MeV No Access No Access 100160 MeV and transfer line 20150817 EDMS 1536236 ID: 467779
Download Presentation The PPT/PDF document "Linac4" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
Slide1
Linac4
Schedule follow-up/forecast
2015-08-17 - EDMS 1536236
J. Coupard EN-MEF
1Slide2
2
2015-08-17 - EDMS 1536236
J. Coupard EN-MEF
50 MeV
No Access
No AccessSlide3
100-160 MeV and transfer line
2015-08-17 - EDMS 1536236
J. Coupard EN-MEF
3Slide4
Surface
2015-08-17 - EDMS 1536236
J. Coupard EN-MEF
4Slide5
Status of the commissioning of the electrical circuits (David Nisbet)
2015-08-17 - EDMS 1536236
J. Coupard EN-MEF
5
Beam
Commissioning
(MeV)
Test bench
(MeV)
Parent equipment
CIRCUIT_NAME
Magnet Name
Magnet/klystron/source Status
Cable Status
MALT
Power Converter Status
WIC test
Tests of the cables
Preliminary tests of the PC
Commissioning
3
Source
L4L.AR.011
L4L.NFHR.0111
installed
ready
commissioned
commissioned
no
commissioned
3
Source
L4L.AR.012
L4L.NFHR.0111
installed
ready
commissioned
commissioned
no
commissioned
3
Source
L4L.AR.013
L4L.NFHR.0111
installed
ready
commissioned
commissioned
no
commissioned
3
Source
L4L.NFH.011
L4L.NFHR.0111
installed
ready
commissioned
commissioned
no
commissioned
3
Source
L4L.NFH.012
L4L.NFHR.0111
installed
ready
commissioned
commissioned
no
commissioned
3
Source
L4L.NFH.013
L4L.NFHR.0111
installed
ready
commissioned
commissioned
no
commissioned
3
Source
L4L.NFH.014
L4L.NFHR.0111
installed
ready
commissioned
commissioned
no
commissioned
3
LEBT
L4L.RLF.111
L4L.MLF.1120
installed
ready
commissioned
yes
commissioned
yes
commissioned
3
LEBT
L4L.RCH.111
L4L.MCHV.1135
installed
ready
commissioned
yes
commissioned
yes
commissioned
3
LEBT
L4L.RCV.111
L4L.MCHV.1135
installed
ready
commissioned
yes
commissioned
yes
commissioned
3
LEBT
L4L.RCH.121
L4L.MCHV.1205
installed
ready
commissioned
yes
commissioned
yes
commissioned
3
LEBT
L4L.RCV.121
L4L.MCHV.1205
installed
ready
commissioned
yes
commissioned
yes
commissioned
3
LEBT
L4L.RLF.121
L4L.MLF.1220
installed
ready
commissioned
yes
commissioned
yes
commissioned
3
RFQ
L4L.AC.22
L4L.ACRFQ.2101
installed
ready
commissioned
yes
commissioned
3
MEBT
L4L.RCH.311
L4L.MCHV.3105
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RCV.311
L4L.MCHV.3105
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQD.311
L4L.MQD.3110
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQF.321
L4L.MQF.3210
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQD.331
L4L.MQD.3310
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQF.341
L4L.MQF.3410
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQF.351
L4L.MQF.3510
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQD.361
L4L.MQD.3610
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQF.371
L4L.MQF.3710
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQD.381
L4L.MQD.3810
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RCH.381
L4L.MCHV.3835
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RCV.381
L4L.MCHV.3835
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQF.391
L4L.MQF.3910
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQD.401
L4L.MQD.4010
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
3
MEBT
L4L.RQF.411
L4L.MQF.4110
installed
ready
ready
commissioned
yes
commissioned
yes
not commissioned
12
DTL1
L4D.AC.01
L4D.ACDT.0125
installed
ready
commissioned
commissioned
12
DTL1
L4D.RCH.021
L4D.MCHV.0205
installed
ready
commissioned
yes
commissioned
yes
not commissioned
12
DTL1
L4D.RCV.021
L4D.MCHV.0205
installed
ready
commissioned
yes
commissioned
yes
not commissioned
12
DTL1
L4D.RQF.021
L4D.MQF.0210
installed
ready
commissioned
yes
commissioned
yes
not commissioned
50
DTL2
L4D.AC.02
L4D.ACDT.0225
installed
ready
commissioned
commissioned
50
DTL2
L4D.RCH.031
L4D.MCHV.0305
not installed
not ready
installed
no
not commissioned
no
not commissioned
50
DTL2
L4D.RCV.031
L4D.MCHV.0305
not installed
not ready
installed
no
not commissioned
no
not commissioned
50
DTL3
L4D.AC.03
L4D.ACDT.0325
installed
ready
commissioned
not commissioned
50
intertank DTL-CCDTL
L4C.RCH.011
L4C.MCHV.0105
not installed
ready
ready
installed
magnet
not commissioned
yes
not commissioned
50
intertank DTL-CCDTL
L4C.RCV.011
L4C.MCHV.0105
not installed
ready
ready
commissioned
yes
not commissioned
yes
not commissioned
50
intertank DTL-CCDTL
L4C.RQF.011
L4C.MQF.0110
installed
ready
ready
commissioned
yes
not commissioned
yes
not commissioned
100
50
CCDTL1
L4C.RQD.021
L4C.MQD.0210
installed (test bench 50MeV)
ready (test bench 50MeV)
installed
yes (test bench 50MeV)
commissioned (test bench 50MeV)
no
not commissioned
100
50
CCDTL2
L4C.RCH.031
L4C.MCHV.0305
installed (test bench 50MeV)
ready (test bench 50MeV)
installed
yes (test bench 50MeV)
commissioned (test bench 50MeV)
no
not commissioned
100
50
CCDTL2
L4C.RCV.031
L4C.MCHV.0305
installed (test bench 50MeV)
ready (test bench 50MeV)
installed
yes (test bench 50MeV)
commissioned (test bench 50MeV)
no
not commissioned
100
50
CCDTL2
L4C.RQF.031
L4C.MQF.0310
installed (test bench 50MeV)
ready (test bench 50MeV)
installed
yes (test bench 50MeV)
commissioned (test bench 50MeV)
no
not commissioned
100
50
CCDTL4
L4C.RCH.051
L4C.MCHV.0505
installed (test bench 50MeV)
ready (test bench 50MeV)
ready
installed
yes (test bench 50MeV)
commissioned (test bench 50MeV)
no
not commissioned
100
50
CCDTL4
L4C.RCV.051
L4C.MCHV.0505
installed (test bench 50MeV)
ready (test bench 50MeV)
ready
installed
yes (test bench 50MeV)
commissioned (test bench 50MeV)
no
not commissionedSlide6
AoB
2015-08-17 - EDMS 1536236
J. Coupard EN-MEF
6