Download Presentation The PPT/PDF document " 1 RGK600 – RGK700 – RGK800" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
Slide1
1
RGK600 – RGK700 – RGK800
RGK900
GEN-SET CONTROLLERS
M60GB05_02_14
GEN-SET CONTROLLERS
Slide2SMALLRGK400SARGK420SASTAND ALONE AND AMF CONTROLLERSCOMPACTRGK600 – RGK610 – RGK600SARGK601 – RGK601SASTANDARDRGK700 – RGK700SAEXPANDABLERGK800 – RGK800 SASYNCRONYSINGAND LOAD SHARING CONTROLLERSRGK900RGK900SARGK900MCACCESSORIES
GEN-SET CONTROLLERS
2
M60GB05_02_14
Slide33
RGK4…SA
Stand alone applicationWithout starting keyRGK400SAWith starting key (OFF, local start, remote start)RGK420SA
GEN-SET CONTROLLERS
M60GB05_02_14
RGK400SA
RGK420SA
Slide44
RGK6…
AMFSTAND ALONEPICK-UP/WNo CANbusRGK600RGK600SACANBUSNo Pick-up/WRGK601RGK601SAPICK-UP/WNo CANbusExpandableRGK610RGK610 programmed as stand alone
GEN-SET CONTROLLERS
M60GB05_02_14
Slide55
AMFSTAND ALONENOT EXPANDABLERGK700RGK700SAEXPANDABLERGK800RGK800SA
GEN-SET CONTROLLERS
RGK700 – RGK800
RGK700
RGK700SA
RGK800
RGK800SA
M60GB05_02_14
Slide6GEN-SET CONTROLLERS
6
RGK900 types
RGK900RGK900SARGK900MCSingle genset in parallel to mains ●--Multiple genset paralleling in island◦●-Multiple genset bus in parallel with mains(ATS with closed transition)--●
Default applicationApplicable with specific parameter programmingNot applicable.
M60GB05_02_14
Slide77
RGK900
GEN-SET
CONTROLLERS
RGK900
Single gen-set in parallel to mains
P
ower
bus
M60GB05_02_14
Slide88
RGK900SA
GEN-SET CONTROLLERS
RGK900SA
RGK900SA
RGK900SA
Multiple gen-set in parallel in island mode
Power bus
CANbus
M60GB05_02_14
Slide99
RGK900 or RGK900SA + RGK900MC
GEN-SET CONTROLLERS
RGK900
RGK900SA
RGK900
RGK900SA
RGK900
RGK900SA
RGK900MC
Multiple generators in parallel with mains
P
ower bus
CANbus
M60GB05_02_14
Slide1010
Auxiliary power supplyRated voltage: 12/24VDC (max consumption 1.1W)Continuous operating range: 7…33VDC for RGK4...SA/RGK6.../RGK700.../RGK800...7…36VDC for RGK900...Minimum value during cranking: 5.5VDC (4.5VDC for RGK4...SA).Voltage inputs4 inputs (L1, L2, L3, N) for mains (only for AMF versions)4 inputs (L1, L2, L3, N) for generatorRated voltage: RGK4...SA-RGK6...: 480VAC (L-L)RGK700...-RGK800...-RGK900...: 600VAC (L-L).Voltage range:RGK4...SA-RGK6...: 50…576VAC (L-L)RGK700...-RGK800...-RGK900...: 50…720VAC (L-L).
GEN-SET CONTROLLERS
M60GB05_02_14
Slide1111
Current inputs1 input for RGK4...SA3 inputs for RGK6... - RGK700...4 inputs for RGK800... (earth leakage monitoring)5 inputs for RGK900... (earth leakage monitoring and load current)CT secondary rated current: 5A or 1A (programmable)Current range: 10mA…6A (CT/5A); 10mA…1.2A (CT/1A).
Built-in connections3 Resistive analog inputs (1 for RGK4...SA)Engine speed inputs: Hz, pick-up/W (not RGK601...)CANbus J1939 (not RGK4...SA and RGK600...)2° CANbus channel for controllers interlink (RGK900... only)Remote alarms/status signal outputRS232 (RGK700... only)RS485 (RGK800... - RGK900... only).
GEN-SET CONTROLLERS
M60GB05_02_14
Slide1212
DIFFERENCES BETWEEN RGK4…SA AND RGK6…
RGK4…SARGK600…Digital inputs5 negative + 1 emergency4 negative + 1 emergencyDigital outputs5 static6 staticAnalog inputs1 resistive/digital3 resistive/digitalExpandability1 slot for EXP1040(2 resistive/digital inputs, 2 static outs)RGK610: 1 slot forEXP1010 (USB)EXP1011 (RS232)EXP1012 (RS485)Front panel dimensions110x110mm144x144mmON/OFF commandRGK400SA: push buttonRGK420SA: 3 position keyRGK600SA: push buttonLCD ScreenWith iconsGraphic LCD 128x80 pixels
GEN-SET CONTROLLERS
M60GB05_02_14
Slide1313
DIFFERENCES BETWEEN RGK600… AND RGK700…
RGK600…RGK700…Digital inputs4 negative + 1 emergency6 negative + 1 emergencyDigital outputs6 static4 static + 3 relayAnalog inputs3 resistive/digital3 resistiveBuilt-in serial port-RS232Front panel dimensions144x144mm240x180mmDegree of protectionIP54IP65 with optional gasketIP65ON/OFF push buttonRGK600SA-LCD Screen50x35mm1750 sqmm72x45mm3240 sqmm
GEN-SET CONTROLLERS
M60GB05_02_14
Slide1414
DIFFERENCES BETWEEN RGK700… AND RGK800…
RGK700…RGK800…Digital inputs6 negative + 1 emergency8 negative + 1 emergencyDigital outputs4 static + 3 relay6 static + 3 relay + 1 pulseAnalog inputs3 resistive4 resistiveEXP module compatibility-3Current inputs34Earth leakage control-●400Hz capability-●Built-in serial portRS232RS485Real time clock-●
GEN-SET CONTROLLERS
M60GB05_02_14
Slide1515
DIFFERENCES BETWEENRGK800… AND RGK900…
RGK800…RGK900…LCD screen128x80 pixels (72x45mm)128x112 pixels (71x61mm)Digital inputs812CANbus channels1 - ECU1 - ECU2 - Genset system linksAnalog outputs-V – PWM forAVR and GovernorMains-Gen parallel operation-RGK900Bus-Gen parallel operation-RGK900SABus-Mains parallel operation-RGK900MCExpansion slots34
GEN-SET CONTROLLERS
M60GB05_02_14
Slide1616
RGK900… REAR
GEN-SET CONTROLLERS
AVR control
Opto-isolated analog output, fully programmable Voltage mode range: -10…+10 VDCPWM mode: 0…5V No need for dip switches, software controlled.GOVERNOR controlIsolated analog output, fully programmable Voltage mode range: -10…+10 VDCPWM mode: 0…5V No need for dip switches, software controlledControl via engine CANbus as well.CANbus for genset interlink / load sharingCAN2: Opto-isolated interface.
M60GB05_02_14
Slide1717
OPTICAL PORT ON FRONT
PC link through
USB (CX01)Wi-Fi (CX02)
REMOVABLE LABELLabel for name customising or plant indication
GEN-SET CONTROLLERS
CX01
CX02
M60GB05_02_14
Slide1818
GEN-SET CONTROLLERS
SCREENSHOTS FOR GRAPHIC DISPLAY
User-friendly interface with completedescriptions during programming(5 languages at the same time)
Easy browsing through measurements and full description texts (5 languages). The texts can be modified through the front optical port.
Customised pages with free text description.Free messages for alarms
Graphs (waveform, stem).
M60GB05_02_14
Slide1919
GEN-SET CONTROLLERS
RGK4…SA DISPLAY
M60GB05_02_14
Backlighted display with icons which shows:symbols for alarms numeric valuestexts for operation messages, alarms and parameters setting.
Slide2020
GEN-SET CONTROLLERS
PID CONTROLLERS FOR GOVERNOR AND AVR
M60GB05_02_14
Slide2121
GEN-SET CONTROLLERS
SYNCHRONISATION
M60GB05_02_14
Slide2222
OPTICAL PORT ON FRONT
AdvantagesNo need to disconnect the panel power supply to connect with the device.Electrical safety (no physical connection).IP65 protection degreeSimple access to the unit on front.
GEN-SET CONTROLLERS
M60GB05_02_14
Slide2323
Using CX02 (Wi-Fi), the following is possible:Project upload/download Controller cloningConnection to the device with apps.
PC link through USB (CX01) or Wi-Fi (CX02) for:ProgrammingDiagnosticsData downloadingFirmware upgrade.
GEN-SET CONTROLLERS
OPTICAL PORT ON FRONT
CX01
CX02
M60GB05_02_14
Slide2424
PROFILE
Low profile and reduced depth are useful during the controller installation even in very compact electrical panels.
GEN-SET CONTROLLERS
RGK7…
/ RGK8… / RGK9…
RGK6…
M60GB05_02_14
Slide2525
INSTALLATION
Metal elements with screws to guarantee adhesion over time
Expandability with EXP series modules
IP65 rubber gasket
Fixing slots for plastic ties provide for orderly cabling
GEN-SET
CONTROLLERS
M60GB05_02_14
Slide2626
IP65 TEST ACCORDING TO
IEC 60947-1
GEN-SET
CONTROLLERS
M60GB05_02_14
Slide2727
LIMIT OF TEMPERATURE TEST FOR LCD
GEN-SET
CONTROLLERS
-30°C
+70°C
M60GB05_02_14
Slide2828
RADIATED EMISSION AND IMMUNITY TEST
GEN-SET
CONTROLLERS
M60GB05_02_14
Slide2929
VIBRATION TEST ACCORDING TO IEC 60068-2-6
GEN-SET
CONTROLLERS
M60GB05_02_14
Slide3030
GEN-SET CONTROLLERS
EXP… EXPANSION MODULES
Plug-in connection at the base unit rearPower supplied by the base unitUp to 1 module for RGK4...SA and RGK610Up to 3 modules for RGK800...Up to 4 modules for RGK900...Plastic retainer for applications with strong vibrations for RGK800... and RGK900...
ADVANTAGESConfiguration flexibilityOnly one code for the base unitPossibility to add functions even after the first installation.
M60GB05_02_14
RGK4...SA
Slide3131
GEN-SET CONTROLLERS
Plug&Play!
Save
Retry
Digital inputs/outputs
EXP1000 - 4 digital inputs
EXP1001 - 4 digital outputs
EXP1002 - 2 digital inputs + 2 static outputsEXP1003 - 2 relay outputs.Analog inputs/outputsEXP1004 - 2 multifunction analog inputsEXP1005 - 2 multifunction analog outputs. EXP1040 – 2 resistive/digital inputs + 2 static outputsCommunication modulesEXP1010 – USBEXP1011 – RS232EXP1012 – RS485EXP1013 – Ethernet (with web server)EXP1015 – GSM/GPRS Modem.
EXP…
EXPANSION MODULES
The controller
automatically recognises the new system configuration.User is asked to confirm or retry.Parameters of expansion modules need to be programmed to take advantage of new features.
M60GB05_02_14
Slide3232
TRADITIONAL CONFIGURATION (external GSM modem)Requirements:RS232 serial communication port available on the device (built-in or added by installing an expansion module)External GSM modem with RS232 port.Operations:Configuration of the serial ports both for the device and the modemModem programming using AT commands (for experts only!).
CONFIGURATION WITH EXP1015Requirements:Support of EXP1015 module.Operations:Plug&play module installation (no configuration necessary!).
GEN-SET CONTROLLERS
EXP1015 GSM/GPRS MODEM EXPANSION MODULE
M60GB05_02_14
Slide3333
12-24VDC
dedicated
supply
CABLE51C7
GSM Antenna
EXP1015
CX03
INSTALLATION
without EXP1015
with EXP1015 + CX03
GEN-SET
CONTROLLERS
M60GB05_02_14
Slide3434
FUNCTIONSSMS sending and receivingEmail sending with data and diagnostic informationFTP client (log file transfer to a remote FTP server)Connection to remote control software.
GEN-SET
CONTROLLERS
M60GB05_02_14
Slide3535
EXP1015 FTP FUNCTION
PC with FTP server (available for free on the web)
Internet connection
Static IP address.
EXP1015
GEN-SET
CONTROLLERS
M60GB05_02_14
Slide3636
EXP1015 FTP FUNCTION
GEN-SET
CONTROLLERS
M60GB05_02_14
Name Dimensions Last update
Index / Test bgs2/
Measurement
VT & CT
Web Slices
Favorites
[ main directory]
Slide3737
GEN-SET CONTROLLERS
FUNCTIONS
Load managementDummy loads:Threshold and delay for activationThreshold and delay for deactivation4 steps.
Load shedding (non-priority loads):Threshold and delay for non-priority load connectionThreshold and delay for disconnectionMaximum configuration: 4 sets of non-priority loads.
M60GB05_02_14
Slide3838
GEN-SET CONTROLLERS
Digital inputs and outputsProgrammable inputs (functions and properties)Programmable outputs (functions and properties)Pulse output (energy and status remoting).
FUNCTIONS
Pulse output
M60GB05_02_14
Slide3939
GEN-SET CONTROLLERS
Analog inputs and outputsProgrammable resistive analog inputsAnalog inputs: 0…10VDC, 0/4…20mA, PT100Analog outputs: 0…10VDC, 0/4…20mA.
FUNCTIONS
M60GB05_02_14
Slide4040
GEN-SET CONTROLLERS
Alarms
More than 50 alarms ready to use8 user alarms:Programmable source (inputs, outputs, limits, remote variables, PLC variables, remote alarms)Free textProgrammable propertiesAcoustic signals:BuzzerSirenBuzzer + siren.
FUNCTIONS
M60GB05_02_14
Slide4141
GEN-SET CONTROLLERS
Fuel statusLevel:Autonomy monitoring2 thresholds for minimum levelFuel theft detection.Filling pump:Start and stop thresholdsManual command.
Current protection
Thermal protection
Earth fault current (leakage) monitoring.
FUNCTIONS
M60GB05_02_14
Slide42GEN-SET CONTROLLERS
42
POWER MANAGEMENT (GEN-GEN)
POWER MANAGEMENT (MAINS-GEN)
Total rated power of running gen-sets
Power
demand
of the load
Actual
reserve
Minimum
reserve (start)
Max
power reserve (stop)
Start / stop
reserve thresholds
Load demand vs. total system power
Max
power
reserve (stop)
Active power management configuration
Mains power
Breaker status / power flow
Mains
PF
Load
demand
Generator
power
Breaker
status /
power flow
Generator
PF
Load
PF
M60GB05_02_14
Slide4343
GEN-SET CONTROLLERS
Engine operationEngine running hours monitoring3 maintenance periods:Independent periodsTotal, engine running, load connected hour count.Rent managementTotal, engine running, load connected hour countProgrammable alarm generation.
FUNCTIONS
M60GB05_02_14
Slide4444
GEN-SET CONTROLLERS
Event list250 eventsReading of the measurement causing the event.
Information pages
1 completely free page
1 system page with free generator description.
FUNCTIONS
M60GB05_02_14
Slide4545
GEN-SET CONTROLLERS
Automatic test
4 operative modes:TestAutoManOff
4 user pages
Selection of 3 measurementsFree titleThe page can be set as the main page.
FUNCTIONS
M60GB05_02_14
Slide4646
GEN-SET CONTROLLERS
Remote variables(virtual inputs).
Password2-level software password1 locking digital input
Limit thresholdsi.e. min ambient temperature to start auxiliary warm-up systems
FUNCTIONS
M60GB05_02_14
Slide4747
GEN-SET CONTROLLERS
Generic countersSource selectionWeight setupFree title text.
Changeover operationContactors (2 outputs)Motorised changeover switches (3 outputs)Motorised circuit breakers (4 outputs)
Mutual standbyExchange by timeExchange by startsMutual help.
RS485
RS232
Status
alarms
FUNCTIONS
M60GB05_02_14
Slide4848
GEN-SET CONTROLLERS
COMMISSIONING
Harmonic analysis and waveformsLoad analysisEnable/disable capability.
Configurations
4 alternative preset configurations
Selection through digital inputs.
Inputs/Outputs
Test mode to force outputs to verify the system
Software adjustment of an offset for resistive inputs to compensate cable length.
PID adjustmentDirect access to PID parameters from displaySetting of PID parameters while engine running.
M60GB05_02_14
Slide4949
BUILT-IN CANBUS J1939
Supported ECUGeneric J1939Volvo (EDC4, EMS, EMS2)Scania (EMS)DeutzPerkinsJohn DeereIveco (Nef, Cursor).
Capability ofMeasurement readingAlarm readingAlarm resetCommands sending.
Status
Alarms
Commands
J1939
GEN-SET CONTROLLERS
M60GB05_02_14
Slide5050
GEN-SET CONTROLLERS
PLC logic
Combination of internal status (engine running, AUT mode, etc.) with alarms and digital inputs to drive programmable outputs and to generate alarms according to the specific application.
M60GB05_02_14
Slide5151
GEN-SET CONTROLLERS
M60GB05_02_14
COMPATIBILITY WITH (CONFIGURATION AND REMOTE CONTROL SOFTWARE)
Slide5252
GEN-SET CONTROLLERS
Synergy is the new software for control and supervision of Lovato Electric products equipped with communication capabilities via serial ports, Ethernet or modem. With this unique software, it is now possible to monitor and control the Lovato Electric devices connected to a heterogeneous network. Device wiring can be done using different types of networks creating communication channels with a simple and intuitive user interface.
M60GB05_02_14
COMPATIBILITY WITH
(SUPERVISION AND ENERGY MANAGEMENT SOFTWARE)
Slide5353
APPLICATIONS FOR SMARTPHONES AND TABLETS
LOVATO Electric applications let the user:Set up the deviceSend commands to the deviceRead values and alarmsDownload statistics and eventsEmail retrieved data.
Wi-Fi connection between the smartphone/tablet and CX02Application and driver upgrade possible if an Internet connection is availableCompatible with iOS and Android.
GEN-SET CONTROLLERS
M60GB05_02_14
Slide5454
GEN-SET CONTROLLERS
RGK4…SA: all the technologies for setup
M60GB05_02_14
Setup operation can be performed through:the front optical port with CX01 (USB) and CX02 (Wi-Fi) donglesNFC interface even if no power supply is available
CX01
CX02
Android
Android
-
iOS
Windows
Slide5555
GEN-SET CONTROLLERS
REMOTE ACCESS DEVICES FOR RGK800
“MIRRORS” of the main controller: the user operates from a remote site as if in front of the device.
RGK 800 RD SA: Remote display for RGK 800 SARGK 800 RD: Remote display for RGK 800Power supply: 12-24VDCBuilt-in RS485 serial port to connect up to 32 devices4 inputs (commands sent to main controller)1 relay output (remote output of the main controller)1 static output (remote output of the main controller).
“Mirror” installed in the control room
Local controller next to the generator
RS485
M60GB05_02_14
Slide5656
GEN-SET CONTROLLERS
REMOTE ACCESS DEVICES FOR RGK800
RGK RA (Remote Annunciator)It is possible to remote display the active alarms, to reset them and mute on-board buzzers.Power supply: 12/24VDC or 100…240VACBuilt-in RS485 serial port to connect up to 32 devices.
RS485
M60GB05_02_14
Slide5757
GEN-SET CONTROLLERS
ALARM-STATUS RELAY UNIT
RGK status (alarms, automatic mode, etc.) remote relay unitEach relay (8 N/O + 4 C/O) corresponds to a logic combination of different status or a single statusUp to 2 units connected together (24 relays).
RGK RR
CODED PULSES
Long distances (1000m)
Refresh time 2.5s
CANBUS
(
parallel with ECU)Short distances (40m)Refresh time 10ms
M60GB05_02_14
Slide5858
GEN-SET CONTROLLERS
INSTALLATIONS
M60GB05_02_14
Slide5959
GEN-SET CONTROLLERS
INSTALLATIONS
M60GB05_02_14
Slide6060
GEN-SET CONTROLLERS
INSTALLATIONS
M60GB05_02_14
Slide6161
COMPETITION
GEN-SET CONTROLLERS
M60GB05_02_14
Characteristics
LOVATO
RGK600
RGK600SA
RGK601
RGK601SA
Deepsea
DSE4410
DSE4420
Deepsea
DSE4510
DSE4520
Deepsea
DSE6010
DSE6020
COMAP
InteliLite
AMF8-9 / MRS3-4
COMAP
InteliNANO
MRS-AMF-PLUS
Configuration from front panel
●
●
●
●
-
● (thresholds and I/O)
Programming from front
●
-
-
-
-
-
Digital inputs
/
outputs
Digital inputs
4
4
4
4
4
2
Emergency input
●
-
-
-
-
-
Digital/Analog inputs
3
-
3
-
-
4
Digital output
6
6
DSE4510: 4
DSE4520: 6
6
MRS3-4: 4
AMF9: 6
6
Engine motion/speed
W input for engine speed
Alt. with CAN Bus
Alt. with CAN Bus
-
Alt. with CAN Bus
-
-
Pick-up input for engine speed
Alt. with CAN Bus
Alt. with CAN Bus
-
Alt. with CAN Bus
-
-
Voltage/current inputs
Generator and mains voltage inputs
3 ph + N
3ph + N
3ph + N
3ph + N
3ph + N
3ph (MRS)
1ph-2ph (PLUS)
Current inputs
3ph
3ph
3ph
3ph
3ph
1ph (PLUS)
Slide6262
COMPETITION
GEN-SET CONTROLLERS
M60GB05_02_14
Characteristics
LOVATO
RGK600
RGK600SA
RGK601
RGK601SA
Deepsea
DSE4410
DSE4420
Deepsea
DSE4510
DSE4520
Deepsea
DSE6010
DSE6020
COMAP
InteliLite
AMF8-9 / MRS3-4
COMAP
InteliNANO
MRS-AMF-PLUS
Analog
inputs
Fuel level input
●
●
●
●
●
●
Oil pressure input
●
●
●
●
●
●
Water temperature input
●
●
●
●
●
●
Functions
AMF function
RGK600/601
DSE4420
DSE4520
DSE6020
AMF9
AMF - PLUS
Event log
50 events
5 events
15 events
5 events
100 events
10 events
Sleep mode
●
-
●
●
-
●
Alternative configurations
4
-
1
1
-
-
Communication
Programming port
USB (CX01)
WiFi (CX02)
USB
USB
USB
USB
USB
Can Bus (J1939)
RGK610/610SA
Alt. with pick-up/W
●
Alt. with pick-up/W
●
●
Housing
Dimensions
144x144x44mm
180x116x42mm
140x113x43mm
215x158x42mm
180x120mm
118x108mm
Slide6363
GEN-SET CONTROLLERS
RGK6… STRONG SELLING POINTS
Commissioning and maintenance helpers: CX01, CX02 I/O forcing, analog sensor adjustmentharmonic analysisDedicated emergency input:the push button directly open the common supply to EV and FUEL outputsalarm condition is generated by RGK6… without auxiliary inputsReal sleep mode (0 mA from battery) for RGK600SA versionGraphic display.
M60GB05_02_14
Slide6464
COMPETITION
GEN-SET CONTROLLERS
M60GB05_02_14
Characteristics
LOVATO
RGK700SA
RGK700
Deepsea
DSE6010
DSE6020
Deep-Sea
DSE7210
DSE7220
COMAP
InteliLite
NT-MRS16
NT-AMF25
Inputs + Outputs
6 + 7
4+4 (pickup)
4+6 (no p.up)
7 + 8
6 + 6 (MRS16)
7 + 7 (AMF25)
Alarms
Nr. of programmable alarms
(+ user’s alarms)
50 + 4
17
23 + 6
22
Programmable property alarms
●
●
●
●
Voltage/Current inputs
Generator voltage inputs
3 ph + N
3 ph + N
3 ph + N
3 ph + N
Mains voltage inputs
3 ph + N
3 ph + N
3 ph + N
3 ph + N
Voltage inputs range
(phase-phase)
50...720
VAC
25…576
VAC
25…576
VAC
0…600
VAC
Analog inputs
Fuel level input
●
-
●
●
Oil pressure input
●
●
●
●
Water temperature input
●
●
●
●
Auxiliary analog input
-
●
-
-
Slide6565
COMPETITION
GEN-SET CONTROLLERS
M60GB05_02_14
Characteristics
LOVATO
RGK700SA
RGK700
Deepsea
DSE6010
DSE6020
Deep-Sea
DSE7210
DSE7220
COMAP
InteliLite
NT-MRS16
NT-AMF25
Functions
Event log
● (250)
● (5)
● (100)
●
PLC function
●
-
-
-
Dual mutual standby
●
-
●
Communication
Modem support
●
-
-
●
Modbus protocol support
●
-
-
●
SMS
●
-
-
●
CAN bus / J1939
●
Option
●
●
RS232
●
-
-
Optional board
RS485
-
-
-
Optional board
Programming port
USB/WiFi
USB
USB
Option
Housing
Dimensions
240x180x40
180x116x42
240x181x42
180x120x55
Slide6666
COMPETITION
GEN-SET CONTROLLERS
M60GB05_02_14
Characteristics
LOVATO
RGK800SA
RGK800
Deep-Sea
DSE7310
DSE7320
COMAP
InteliCompactNT SPtM/MINT
COMAP
InteliGen
NT-NTC
Inputs + Outputs
8 + 10
8 + 8
9 + 8
12 + 12
Alarms
Nr. of programmable alarms
(+ user’s alarms)
50 + 8
n.a.
n.a.
n.a.
Programmable property alarms
●
●
●
●
Voltage/current inputs
Generator voltage inputs
3 ph + N
3 ph + N
3 ph + N
3 ph + N
Mains voltage inputs
3 ph + N
3 ph + N
3 ph + N
3 ph + N
Voltage inputs range
(phase-phase)
50...720
VAC
25…576
VAC
0…600
VAC
0…600
VAC
Analog inputs
Fuel level input
●
●
●
●
Oil pressure input
●
●
●
●
Water temperature input
●
●
●
●
Auxiliary analog input
●
●
-
-
Functions
Event log
● (250)
●
●
●
PLC function
●
●
●
●
Dual mutual standby
●
●
●
●
Slide6767
COMPETITION
GEN-SET CONTROLLERS
M60GB05_02_14
Characteristics
LOVATO
RGK800SA
RGK800
Deep-Sea
DSE7310
DSE7320
COMAP
InteliCompactNT SPtM/MINT
COMAP
InteliGen
NT-NTC
Communication
Modem/SMS support
●
●
●
●
Modbus protocol support
●
●
●
●
Ethernet
with EXP
External module
External module
External module
CAN bus / J1939
●
●
●
●
RS232
-
●
Optional board
●
RS485
●
●
Optional board
●
Programming port
USB/WiFi
USB
Option
USB/RS232
Housing
Dimensions
240x180x40
240x181x42
180x120x55
180x120x55
Expandability
●
●
●
●
Slide6868
GEN-SET CONTROLLERS
RGK7… & RGK8… STRONG SELLING POINTS
Commissioning and maintenance helpers: CX01, CX02 I/O forcing, analog sensor adjustmentharmonic analysisBuilt-in CANbus J1939Low profile and reduced depth to install the controller in very compact electrical panelsSupport for EXP series expansion modules (only RGK800...)Metallic elements with screws for long-lasting fixingMutual standby functionIntegration in Synergy software.
M60GB05_02_14
Slide6969
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Deepsea
Comap
RGK900SA
RGK900
RGK900MC
DSE7510
DSE7520
DSE7560
DSE8610
DSE8620
DSE8660
DSE8810
-
DSE8860
InteliGenNT
-
InteliMains
InteliGenNTC
-
InteliMains
InteliSYSNT
-
InteliMains
Configuration from front panel
●
●
●
●
●
●
●
Programming from front port
●
-
-
-
-
-
-
Programming port
Frontal port with
CX01 (USB)
CX02 (WiFi)
Back port with DSE810 interface
RS232
USB
USB
USB
RS232
RS485
USB
RS232
RS485
RS232
RS485
Maximum rated voltage Ue
600VAC L-L
480VAC L-L
480VAC L-L
480VAC L-L
600VAC L-L
600VAC L-L
600VAC L-L
Current inputs
5
5
5
4
4
4
4
Slide7070
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Deepsea
Comap
RGK900SA
RGK900
RGK900MC
DSE7510
DSE7520
DSE7560
DSE8610
DSE8620
DSE8660
DSE8810
-
DSE8860
InteliGenNT
-
InteliMains
InteliGenNTC
-
InteliMains
InteliSYSNT
-
InteliMains
Digital
inputs
12 + 1 for emergency pushbutton
9
11
11
12
12
16
Digital outputs
10
7
10
10
12
12
16
Operating temperature
-30 - +70°C
-30 °C to +70 °C
-30 °C to +70 °C
-30 °C to +70 °C
-20 to +70°C
-20 to +70°C
-20 to +70°C
Frontal protection degree
IP65
IP42
(IP65 with optional gasket)
IP42
(IP65 with optional gasket)
IP42
(IP65 with optional gasket)
IP65
IP65
IP65
Dimension
240x180x44mm
240.0 x 181.1 x 41.7 mm
240 x 181.1 x 41.7 mm
245 x 184 x 50 mm
185 x 123 x 123 mm
185 x 123 x 123 mm
185 x 123 x 123 mm
Slide7171
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Deepsea
Comap
RGK900SA
RGK900
RGK900MC
DSE7510
DSE7520
DSE7560
DSE8610
DSE8620
DSE8660
DSE8810
-
DSE8860
InteliGenNT
-
InteliMains
InteliGenNTC
-
InteliMains
InteliSYSNT
-
InteliMains
AVR
Direct connection
Direct connection
Direct connection
Direct connection
External insulator
External insulator
External
insulator
Governor
●
●
●
●
●
●
●
PWM
●
-
-
-
●
●
●
Multi gen Island
●
●
●
●
●
●
●
AMF function
RGK900
DSE7520
DSE8620
-
●
●
●
Multi gen AMF
RGK900MC + RGK900SA
DSE7560 + DSE7510
DSE8660 + DSE8610
DSE8810 + DSE8860
InteligenNT + InteliMains
InteligenNTC + InteliMains
InteliSYSNT + InteliMains
Baseload
●
●
●
●
●
●
●
Peak shaving
●
●
●
●
●
●
●
R.O.C.O.F & Vector Shift
●
●
●
●
●
●
●
PID regulation
On front
PC
PC
PC
PC
PC
PC
Slide7272
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Deepsea
Comap
RGK900SA
RGK900
RGK900MC
DSE7510
DSE7520
DSE7560
DSE8610
DSE8620
DSE8660
DSE8810
-
DSE8860
InteliGenNT
-
InteliMains
InteliGenNTC
-
InteliMains
InteliSYSNT
-
InteliMains
Communication
USB (EXP)
RS232 (EXP)
RS485 (Built-in)
Ethernet (EXP)
USB
RS232
RS485
USB
RS232
RS485
Ethernet
USB
RS232
RS485
Ethernet
RS232
RS485
USB
RS232
RS485
Ethernet
RS232
RS485
Slide7373
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Woodward
RGK900SA
RGK900
RGK900MC
easYgen-2200 P1
-
-
easYgen-2500 P1
-
-
easYgen-3200 P1
-
-
easYgen-3500 P1
-
-
Configuration from front panel
●
●
●
●
●
Programming from front port
●
-
-
-
-
Programming port
Frontal port with
CX01 (USB)
CX02 (WiFi)
DPC cable
DPC cable
DPC cable
DPC cable
Maximum rated voltage Ue
600VAC L-L
600VAC L-L
600VAC L-L
600VAC L-L
600VAC L-L
Current inputs
5
4
4
4
4
Slide7474
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Woodward
RGK900SA
RGK900
RGK900MC
easYgen-2200 P1
-
-
easYgen-2500 P1
-
-
easYgen-3200 P1
-
-
easYgen-3500 P1
-
-
Digital
inputs
12 + 1 for emergency pushbutton
8
10
12
12
Digital outputs
10
6
11
12
12
Operating temperature
-30 - +70°C
-20 to +70°C
-20 to +70°C
-20 to +70°C
-20 to +70°C
Frontal protection degree
IP65
IP65
IP65
IP65
IP65
Dimension
240x180x44mm
219 × 171 × 61 mm
219 × 171 × 98 mm
282 × 217 × 99 mm
282 × 217 × 99 mm
Slide7575
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Woodward
RGK900SA
RGK900
RGK900MC
easYgen-2200 P1
-
-
easYgen-2500 P1
-
-
easYgen-3200 P1
-
-
easYgen-3500 P1
-
-
AVR
Direct connection
Direct
connection
Direct connection
Direct connection
Direct
connection
Governor
●
●
●
●
●
PWM
●
●
●
●
●
Multi gen Island
●
●
●
●
●
AMF function
RGK900
●
●
●
●
Multi gen AMF
RGK900MC + RGK900SA
●
●
●
●
Baseload
●
●
●
●
●
Peak shaving
●
●
●
●
●
R.O.C.O.F & Vector Shift
●
●
●
●
●
PID regulation
On front
PC
PC
PC
PC
Slide7676
GEN-SET CONTROLLERS
COMPETITION
M60GB05_02_14
LOVATO
Woodward
RGK900SA
RGK900
RGK900MC
easYgen-2200 P1
-
-
easYgen-2500 P1
-
-
easYgen-3200 P1
-
-
easYgen-3500 P1
-
-
Communication
USB (EXP)
RS232 (EXP)
RS485 (Built-in)
Ethernet (EXP)
-
RS485
RS232
RS485
RS232
RS485
Slide7777
GEN-SET CONTROLLERS
RGK9… STRONG SELLING POINTS
Commissioning and maintenance helpers: CX01, CX02 I/O forcing, analog sensor adjustmentharmonic analysisPID configuration directly on the unitPower management pages with graphic descriptionSyncronisation pages with graphic descriptionNo external devices required for syncronisation and parallel operationIntegration in Synergy software.
M60GB05_02_14
Slide7878
www.LovatoElectric.com
Thank you
for your attention!
GEN-SET CONTROLLERS
M60GB05_02_14
www.LovatoElectric.com
Thank
you for the attention!
GEN-SET CONTROLLERS