ciency, ptical cryostat for use in microscopy, spectroscopy, wafer pr ciency, ptical cryostat for use in microscopy, spectroscopy, wafer pr

ciency, ptical cryostat for use in microscopy, spectroscopy, wafer pr - PDF document

alida-meadow
alida-meadow . @alida-meadow
Follow
395 views
Uploaded On 2016-03-10

ciency, ptical cryostat for use in microscopy, spectroscopy, wafer pr - PPT Presentation

RYO Microscopy Cryostat System RYO Compact lightweight and portable easily inte Ef cient lower cryogen consumption Flexible operates in any orientation Optimized adjustable close worki ID: 249958

RYO Microscopy Cryostat System RYO

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "ciency, ptical cryostat for use in micro..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

RYO ciency, ptical cryostat for use in microscopy, spectroscopy, wafer probing, IC testing and more.asy to operate and Performance by Design. Open the  ow valve; insert the transfer line into a storage dewar and cooling commences. Operates with liquid helium or nitrogen.nterchangeable sample holders provide height adjustment and optimize the cryostat for varying samples and di erent experimental con gurations.  e sample can be set to be very close to the window.ighly efficient detachable stainless steel flexible transfer line connects the microscopy WORKSTATION to a stor-age (transport) dewar. Incorporated in the system is our XE insulating technology for the highest in efficiency.dd a magnetic field now or later. Versatile design allows magnet and microscopy cryostat to be used together or independently. Select a 2 Tesla or 5 Tesla superconducting magnet field!€ Large clear view windows ection and transmissionExtra thin windows available1.5 mm (0.06Ž) is standard€ Short working distanceSample height adjustment up to the window€ Ultra low nanometer drift and sample vibration€ Sturdy strong stable sample support€ HiRes-NOMOVE design results in near zero movement due to thermal contraction€ Operating temperature range - € Efficient with Push (pressurized storage dewar) or Pull (small vacuum pump operation€ Use either liquid helium or nitrogenTHIN fits more microscopes€ Compact, lightweight and portable, easily inte-grated into microscopes and spectrometers€ Efficient economical operation - lower liquid helium consumption using our break-through XE insulating system€ Versatility - expansion kits include 2 inch wafer probing, DIP IC testing, magnetic fields ........ Microscopy Cryostat System RYO Compact - lightweight and portable, easily inte- Ef cient - lower cryogen consumption, Flexible - operates in any orientation Optimized - adjustable close working distance genic Workstation Variable temperature - Versatile - Use either liquid helium or nitrogen - ‘push-or-pull’ operation RYO The RC102-CFM is a sample in vacuum cryostat. The sample holder is located in vacuum. A flow of liquid helium or nitrogen cools the sample, which can be adjusted away from or very close to the window using vari-height thread in sample holders. For high rigidity and stabil-ity, the sample is supported by opposing tension supports.Liquid cryogen is delivered to the sample mount through the vacuum insulated transfer line. An adjustable needle valve provides  ow rate control. Connect the heater on the sample mount to the temperature controller for automatic variable temperature operation. e WORKSTATION can be operated in any orientation.  e standard system includes a six (6) foot (8 foot optional)  exible transfer line with a 50 inch long (60 inch optional) storage dewar leg. e typical setup consists of the RC102-CFM cryostat, a liquid helium (or nitrogen) storage dewar, helium gas cylinder with pressure regulator and a vacuum pump. A stainless steel  exible transfer line is supplied with the system. e transfer line leg inserts into the liquid cryogen. A small pressure is used to transfer the liquid out of the storage dewar, through the transfer line and directly to near the sample mount. Alternately, a small vacuum pump can be used to pull the liquid helium from the storage dewar. A  ow control valve regulates the cryogen  ow. Pressure inside the storage dewar cryogen reservoir can be adjusted using a helium gas cylinder. An activated charcoal cryopump built into the transfer leg will automatically pump when inserted into liquid helium or low pressure nitrogen dewar, maintaining excellent vacuum during extended periods of operation.  e transfer line quick disconnects to and from the microscopy WORKSTATION.Electrical connections to the sample are made through the o-ring sealed ports located on the instrumentation housing. A spare port is provided for future requirements. For safety, the shroud and transfer line are protected against overpressure by pressure reliefs. e evacuation valve for the transfer system is located above the valve control knob.  e evacuation valve for the sample region is on the instrumentation housing.  e vacuums are completely independent.Windows at 0 and 180 degrees provide optical access. For re ection, the total angle of acceptance is 130 - 152 degrees, depending on sample position. For transmittance, the angle used quartz, 1.5 mm thick (0.5 mm thick option is available); suprasil, ZnSe and other window materials can be selected.  e standard clear view aperture is 24 mm diameter (13 mm for 0.5 mm thick windows).  e adjustable holder allows the sample to be moved right up to the window. Samples can be mounted through the radiation shield opening or half the radiation shield is removable to allow full access.Variable temperature is automated using an electronic temperature controller. A heater is imbedded in the sample holder. Set the temperature into the con-troller and obtain the desired temperature. Operation below 4K is achieved by reducing the  ow pressure by pumping on the helium vent. Temperature range3.2 K to 325 KCool down time20 minutes typicalTemperature stabilityBetter than +/- 50 mKWeight3.2 kgVibrational amplitude20 nmDrift (over 1 hour)+/- 150 nmLHe usage~0.7 l/hr at 5K RYO PUSH OR PULL?CRYO Industries  ow cryostats can be operated in push or pull operating modes. Liquid cryogen helium or nitrogen can be drawn from the main reservoir into the sample region by either: PushingŽ - A small pressure in the storage dewar pushes the cryogen from the stor-age dewar into the transfer line to the sample mount.Or,PullingŽ - Sucking liquid from the main storage dewar to the cold  nger by using a small pump.  e liquid helium is drawn from the main reservoir of the storage dewar into the sample mount using a small diaphragm (gas  ow) pump, while maintaining the storage dewar near one atmosphere.€ 3.2 K to 325 K operating temperature range • Operates with either LHe or LN• Operates in Push or Pull modes Pull - pump = ‘pull’ • (2) 0.93 inch [23.6 mm] diameter windows(2) 0.93 inch [23.6 mm] diameter windows0.020 inch [0.5 mm] thick window optional• Windows top and bottom • Adjustable sample holder• 50 ohm heater installed on sample mount• 19-pin hermetic electrical feedthrough• Spare blank feedthrough port• NW25 vapor pumping port & vacuum valve• Flexible stainless steel transfer line ow control valve• Silicon diode temperature sensor installed• 30 mm thin• Solid - internal support spacer RYO What is a NOMOVE?The sample holder is supported radially with opposite and equal support forces. The supports are rigid and anchored directly to the outer vacuum jacket. There is no physical support to the sample holder through the cold finger and radiation shield,. The sample is physically de-coupled from the internal thermally contracting (moving) cold components. Thermal contraction is toward the center of the sample, resulting in the lowest movement design. The supports are designed to operate in the elastic region. Supports are rigid and under tension. Movement toward or away from the window is virtually zero because there is no support component in this z-direction.Lowest Vibration t your setup. ciency, excellent RYO holders allow for quick sample change, adjustable distances and selectable diameters and apertures. ow of liquid helium or nitrogen cools the sample, which justed for varying sample thicknesses. The sample holder is supported by opposing tension forces, anchored directly to the outer Remove the full size cover. The sample can be quickly accessed Add a Magnetic Fieldfor use with electromagnets • Fits narrow 1.0 inch gap• Strain free window mounting (top window)• Mates to top of cryostat - no modi cations needed eld - select 2 Tesla or 5 Tesla RYO provides a 5 Tesla magnetic field in a Room Temperature Bore (RTB). A compact table top design that mates to the microscopy cryostat and offers high efficiency, easy of operation, ultra low vibration and is also available in a cryogen free design. is a 2 Tesla version. can be separated from the microscopy cryostat providing independent operation and a high magnetic field in a 1.875Ž [47.6 mm] diameter bore for use with many other different experiments. An EZ install sample extender kit is available to position the sample in the microscopy cryostat in the center of the magnetic field.asy to operate and Performance by Design. Open the  ow valve; insert the transfer line into a storage dewar and cool-ing commences. Efficient detachable stainless steel flexible transfer line connects the microscopy WORKSTATION to a storage (transport) dewar. Incorporated in the system is our XE insulating technology for the highest in efficiency.he magnetic bore can be orientated horizontally or vertically.ersatile design allows magnet and microscopy cryostat to be used together or independently. The magnetic field can be added to the microscopy cryostat now or later. Select a 2 Tesla or 5 Tesla superconducting magnet field!€ Large Magnetic FieldSelect 5 Tesla or 2 Tesla€ Large Room Temperature Bore (1.87Ž [47.6 mm])€ Integrates directly to standard microscopy cryostat€ Demounts from the sample microscopy cryostat and is capable of independent operation for other experimental applications€ Magnet cryostat does not need to be physically coupled to sample cryostat€ The magnetic field and magnet bore can be orientated horizontally or vertically, relative to € Location of magnetic field center only 74.6 mm from top Micromag 5 Tesla magnet system C8 Magnetic Fieldup to 5 TeslaSample Temperature Cool down time~ 4 hoursHelium Consumption1.0 l/hr vertical ow pumpWeight10 kg ow cryostat RYO eld Room Temperature Bore (RTB) ts over microscopy cryostat CRYO Industries • http://www.cryoindustries.com RYO C11 CCESSORY afer Probing Kit Wafer Probing Kit or 2 inch wafers for 2 inch wafers ual or single wafer Dual or single wafer ounting. mounting. ual mounting al- Dual mounting al- ows probing one lows probing one ide, ß ip it over and ip it over and robe the second probe the second afer. wafer. CCESSORY - DIP IC TESTING CRYO Industries • (603) 621-9957 • cryo@cryoindustries.com USTOMIZE/OTHER CONFIGURATIONS Customization and other con gurations are available. Some examples are diamond cell anvil (shown in picture), nano-positioning stage from Attocube, manual external posi-tioning stage, UHV (Ultra High Vacuum) and more. Diamond cell anvil cryostat RC102-CFMC12 C13