/
WIKA data sheet AC09.01 ∙ 07/2015Page 3 of 3 WIKA data sheet AC09.01 ∙ 07/2015Page 3 of 3

WIKA data sheet AC09.01 ∙ 07/2015Page 3 of 3 - PDF document

briana-ranney
briana-ranney . @briana-ranney
Follow
393 views
Uploaded On 2016-08-07

WIKA data sheet AC09.01 ∙ 07/2015Page 3 of 3 - PPT Presentation

ID: 437445

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "WIKA data sheet AC09.01 ∙ 07/2015..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

WIKA data sheet AC 09.01 ∙ 02/2017Page 3 of 3 Standard versionOrdering informationTo order the described product, the given order number is su�cient. Other options require additional speci�cation. Entry SWWeight in kgFemale / femaleFemale / maleFemale / femaleFemale / maleUnion nut / femaleFemale / femaleFemale / maleFemale / femaleFemale / maleUnion nut / female WIKA Alexander Wiegand SE & Co. KGAlexander-Wiegand-Straße 3063911 Klingenberg/GermanyTel.Faxinfo@wika.dewww.wika.de © 03/2003 WIKA Alexander Wiegand SE & Co. KG, all rights reservedThe speci�cations given in this document represent the state of engineering at the time of publishing.We reserve the right to make modi�cations to the speci�cations and materials. Page 2 of 3WIKA data sheet AC 09.01 ∙ 02/2017 Standard versionCock case (wetted part) and handleMaterial: Brass CW614N Handle installed in the case with silicon free greaseTest connectionTest pivot M20 x 1.5or test �ange Ø 40 x 5 mm resp. 60 x 25 x 10 mmWetted parts:Brass, CW614N , chrome platedWith gland packing, without venting bore (only at standard version)Special threads Wetted partsOrder numberFemale / femaleBrassBrassBrassBrassBrassBrassFemale / maleBrassBrassBrassBrassBrassBrassUnion nut / femaleBrassBrassBrassBrassBrassBrassBrassAlternative: Brass CW617NMedium temperature ≤ +80 °C without venting bore WIKA data sheet AC 09.01 Page 1 of 3 Stopcock for pressure measuring instrumentsModel 910.10, brass, steel or stainless steelData sheets showing similar products:Shut-o� valves for higher pressures; model 910.11; see data sheet AC 09.02 Shut-o� device for pressure measuring instruments, for measurement of liquids, gases and vapoursSpecial featuresVersion per DIN 16261, DIN 16262 and DIN 16263Nominal pressures to ≤ 25 barOperating temperature ≤ 50 °CStopcocks provide the opportunity to either vent the connected pressure gauge according to the position of the handle (venting position), i.e. put it into a pressure-free state, or to vent the pressure measuring instrument under pressure (operating position) or to let the medium escape (blow position). The table on page 2 lists the nominal pressure PN for each version.For higher pressures shut-o� valves must be used.Test connection versionStopcocks with test connection are intended for the simultaneous connection of operating pressure measuring instruments and test connection pressure gauges to the pressure pipeline. With this version, the third route, which leads to the outside at the standard version, is used as connection for a test connection pressure gauge. A fourth of the operating and the test connection pressure measuring instruments to the pressure pipeline. Accessories Female / male G ½ / G ½ B, DIN 16261, PN 25WIKA data sheet AC 09.01