1 iBall 1 iBall

1 iBall - PowerPoint Presentation

celsa-spraggs
celsa-spraggs . @celsa-spraggs
Follow
381 views
Uploaded On 2015-10-28

1 iBall - PPT Presentation

Instruments LLC Innovative Solutions for Remote Monitoring and Measurement 2 Who is iBall Instruments LLC Owner Engineer Carl Bright 19 Years of New Product Development For Oil and Gas ID: 175294

data system detector gas system data gas detector bloodhound infrared iball chromatograph software server internet support amp instruments power

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "1 iBall" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

1

iBall Instruments LLC

Innovative Solutions for Remote Monitoring and MeasurementSlide2

2

Who is iBall Instruments LLC?

Owner / Engineer: Carl Bright

19 - Years

of New Product

Development For Oil and Gas

Hardware, Software, and Mechanical Engineer

R&D Lab & Machine Shop in McLoud, OK

Repair, Maintenance, and supply Office

in Edmond,

Oklahoma

New Product Development and MarketingSlide3

3

Accomplishments for the Mud Logging Industry

Bloodhound Infrared Gas Detector and

Chromatograph SystemBloodhound

Hotwire Gas Detector and Chromatograph System

Interceptor Fast Fourier Infrared Gas Detection System

Low Voltage Safe DC Cavitator System

Patent Pending Software Allows for Self Correcting and Automatic Detection of Failed SensorsSlide4

4

History of BloodhoundGas Detector & Chromatograph

System

1st

Prototype in

December 2005 Old Pellistor

Technology

Six (6) Months Field Testing

1

st

Infrared

Version December 2006

Four (4) Months Field Testing

Production Design Complete May 2007

U.S. Patent Pending Issued December 2013

Additional New Hotwire Like Device Deployed June 2014Slide5

5

Bloodhound Gas Detector and ChromatographSlide6

6

CE CertifiedSlide7

7

Typical Easy Installation in Logging TrailerSlide8

8

Proprietary Infrared Hotwire Replacement Module (HRM)Slide9

9

Internal Universal Power Supply

Any

Bad Power Between 90 and 265 VAC

Any

Bad Power Frequency

45 to 65 Hz

Easly

Handles bad and dirty

rig power

Internal

Gel Cell Backup 2.5 HoursSlide10

10

Automated Data System Operation

Bloodhound Connects to Server at

Power Up

Data Packets transmitted every

6 Seconds to Central Server System

Triple Redundancy of Data Storage

USB Memory Stick

Hard Drive of connected PC

File Servers at

iBall Instruments

Facility

File Server Creates Viewable Web Page

Browser only (No Special Software)

Secure Web

SiteSlide11

11

Data Packet Contents

Bloodhound Serial #

Drill DepthGas UnitsH2S PPM

ROP

Min/Ft

ROP

Rate Ft/

Hr

Error Number

%

Gasses

LEL

PPM

CG

Data

Date & Time

Internal Voltage

Sample

LPH

Sample

VAC

mmHg

Temperature (internal)

iBall Date/Time

Primary Voltage

Secondary Voltage

H2S

Voltage

More!Slide12

12

Data Packets Converted to Usable Charts and Data Files for Download at Website

iBall Instruments proprietary software converts data packets into

images at File Server for customer viewing and downloading

Websites are

viewable

with

secure user ID and PasswordSlide13

13

Bloodhound System Is Accessible World-Wide Via

Internet In Real-TimeSlide14

14

Bloodhound Instrument

GPRS Cell Radio

AT&T Data Service

Field Data Network

Ethernet connection

(e.g. Sat. Internet)

Data Logger - Remote

Windows

Application

Data Logger - Local

Windows Application

(Gas_Chart.exe)

Gas Chart Data Logger

Calculates Lag

Set PC Alarms

Edit Depth

Chromatograms

Data File Export

Connection to

Instrument

At

Well Site

Web Remote Data

Web Browser

Communication Network

Internet

64.19.102.xx:xxxx

WITS

iBall Instruments

Server System

Well Site PC

Remote PC

Mobile Device AccessSlide15

15

Server System for Over 500 Bloodhounds World-Wide

Hardened CO Site Up To Class 5 Tornado

24/7 Wet Battery Backup For Up To 2 Days

Automatic Natural

Gas

Generator Backup

Three 10 Megabit Symmetrical

Internet

ConnectionsSlide16

16

A Complete Gas Detection System

Dedicated File Servers

for Every

Bloodhound

Triple Redundancy of

Data Collected

Integral Chromatograph

H2S, O2 and CO2 Detection

Real-time Access

and Download via

Internet

24/7 Product SupportSlide17

17

Real Time Data ViewerSlide18

18

24/7 Tech Support Center

2009

Established 24/7 SupportWorld-Wide telephone & Internet Support And ServiceExperienced loggers And Geologists Take Technical Support Calls

System Provides Automated Text Messaging

Bloodhound

Status Through Telephone System

Rentals/Dispatch/Repairs

Remote

Diagnostics Support And ServiceSlide19

19

Visible Configurable Raw ChromatographSlide20

20

System Advantages

Uses

Infrared Detectors With Very Good Longevity

Extremely Accurate

And

Fast

Response

Minimum

DRIFT And Auto-Zero Chromatograph

Unaffected by Temperature or Shock

1% to 100%

Gas Units

without

Saturation

Free

Gas Detection Software

Free Website Interface SystemSlide21

21

Infrared Detectors

Not a new idea

Earlier attempts unsuccessfuliBall Instruments Developed

New Methods

Modulated light

Source

New tungsten

Filament Infrared Source

New Lithium

Tantalate

Pyroelectric

detectorSlide22

22

How Does It Work?

Sample

gas diffused into Optical Chamber through filterLithium/Pyroelectric sensors provide output to patent pending software

Adjustable pulse

rate 4Hz at 50% Duty

Reduces background Interference to nearly Zero

Detector signals consist of ripples superimposed on DC offsetSlide23

23

Genareal Infrared Measurement SystemSlide24

24

Multiple Detectors

Reference Detector Has Minimal Filtering

Hydrocarbon Active Detector Filter Transparent to strong absorption band of

gases

CO2 Active Detector Filter Only Passes absorption band Inerrant to CO2

Allows

short optical path yet maintains good resolution

Output ripple is reduced as radiation is attenuated

Built In Temperature Sensor For Temperature Compensation

Ratio

differences determines

level of target gasSlide25

25

Operational Bloodhounds Found World Wide

Arkansas, Texas, Oklahoma,

Utah, North Dakota, South Dakota, Pennsylvania, New York, Illinois

, Indiana, New Mexico, Ohio,

Kansas

, Colorado,

Kentucky, Turkey

,

Azerbajain

, Morocco,

Ukraine

, South Africa, Belize, Chile,

New Zealand…Slide26

26

CavitatorGas

Extraction SystemSlide27

Cavitator – Multiple Motor System

Explosion Proof AC, DC, And Air Motor Design

27

Related Contents