Keratech Astigmatic Rule Keratech Astigmatic Rule

Keratech Astigmatic Rule - PDF document

daniella
daniella . @daniella
Follow
342 views
Uploaded On 2022-08-16

Keratech Astigmatic Rule - PPT Presentation

Fig 1 Fig 2 Fig 3 Fig 4 Instructions Altomed Limited 2 Witney Way Boldon Business Park Tyne Wear England NE35 9PE For further assistance or to place orders please contact customer servi ID: 936762

device rule astigmatism image rule device image astigmatism circular lens axis shape clock fig figure distance aligned instrument flat

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "Keratech Astigmatic Rule" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Fig 1. Fig 2. Fig 3. Fig 4. Keratech Astigmatic Rule - Instructions Altomed Limited, 2 Witney Way, Boldon Business Park, Tyne & Wear, England, NE35 9PE. For further assistance or to place orders, please contact customer services on: Tel: (0) 191 519 0111 Fax: (0) 191 519 0283 . Determining the end - point with the Keratoscopic Rule. This diagram shows an example of the change in the elliptical image from astigmatism with - the - rule to the end - point (a circular image) and beyond to against the rule 1. Prepara tion (figure 1).  Close the wound water tight  Re - inflate the anterior chamber with balanced salt solution to a normal physiological pressure  Release the superior rectus suture  A tight wound will give astigmatism with - the - rule 2. Set the distance (figure 2 ).  Hold the instrument so that the inner edge of the circular (0) lens is just aligned with the limbus; this sets the distance the rule should be held from the eye (i.e. 20mm)  Always keep the inner edges of the lenses aligned with the limbus at 9 o’clock and 3 o’clock to keep the distance set 3. Align the axis (figure 3).  Again using the circular lens (0) align the handle of the instrument with the long axis of the corneal image  Be sure not to tilt the instrument as this changes the shape of the image and gives a false reading  With - the - rule astigmatism will have the long axis of the image at 180º, 3 o’clock to 9 o’clock 4. Observe the image shape (figure 4).  Note the image produced by each lens in turn  The end point is when the imag e becomes most circular  Remember to keep the distance set and axis aligned correctly  The magnitude of astigmatism in dioptres is given by the lens number Form ALT I019 Issue 0 4 / 1114 The Keratech Astigmatic Rule is a rack of elliptical Kerat oscopic lenses corresponding to increasing magnitudes of astigmatism. The amount of corneal astigmatism (in dioptres) is determined by noting the lens that causes the reflection from the cornea to be circular. Pre - Use Checks 1. Ensure the device is flat and has not been warped during processing 2. Ensure the device is not physically damaged or discoloured 3. Ensure the scale is clearly visible Sterilization 1. Wash device to remove any visible contaminants using hospital approved pH neutral detergent 2. Plac e the device flat in the autoclave. If the device is not flat the shape may become distorted. 3. Autoclave on a standard 134°C (max 137°C) cycle with a 3 minute holding time. 4. Follow the Department of Health Guidelines for management and decontamination of med ical devices where appropriate. Note: Although the plastic is heat stable and the device can be autoclaved many times, it will eventually start to become opaque an d the shape may distort. It is recommended to replace the device once this starts to happen.