Measurement  of  dE /dx Measurement  of  dE /dx

Measurement of dE /dx - PowerPoint Presentation

fanny
fanny . @fanny
Follow
0 views
Uploaded On 2024-02-16

Measurement of dE /dx - PPT Presentation

resolution with resistive Micromegas P Colas S Suvorov M Zito dE dx essential in detailed Higgs and top analysis PID for B and charm reconstruction b charge ID: 1046388

2018de resistive resolution charge resistive 2018de charge resolution track modules rows dependence pads drift beam data 2014 140 distance

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Measurement of dE /dx" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1. Measurement of dE/dx resolution with resistive MicromegasP. Colas, S. Suvorov, M. Zito

2. dE/dx essential in detailed Higgs and top analysis (PID for B and charm reconstruction, b charge tagging)So far used successfully in the T2K ND280 TPCfor e/µ separationBut this was a standard anode TPC, with no charge sharing. We have to investigate the effect of charge sharing on dE/dx resolution, using DESY test beam data.Introduction29/05/2018dE/dx with resistive Micromegas2K. Abe et al., ‘Measurement of the intrinsic electron neutrino component in the T2K neutrino beam with the ND280 detector’, Phys.Rev. D89 (2014) 092003pads meshEB~100m Amplification gap: resistive foil: ~75minsulator: ~100m

3. Data 2014 middle module (mod 3) is extremely stableother modules show degradation in timestrategy: make pseudo-long track from 8 different tracks crossing the middle moduleData 2015long tracks along all three modules can be usednot all the pads can be used strategy: extract dead pads from the study29/05/2018dE/dx with resistive Micromegas3Used 2014 and 2015 campaigns to estimate dE/dx resolution. 5 GeV/c electron beam along the pad columns24 rows (the 1st and 24th receive 50% of the charge, the other 50% are lost in the crack between modules due to E-field distortion)Method:For each pad take maximum charge from ADC ()Sum up pads in a row to make a cluster ()For each track sort in increasing order (N clusters per track)Take first clusters.Truncated mean energy per clusterVary to reach best resolution 

4. 29/05/2018dE/dx with resistive Micromegas4Calibration: equalize row-charge most probable valuesDo not use 1st and 24th line (they receive only part of the charge), but count them as inefficient, to be conservative.rowrowMost probable charge per roww/o calibrationw/ calibrationCharge per row

5. 29/05/2018dE/dx with resistive Micromegas5First check: 1 module 22 rows x 7 mm B = 0 w/o calibrationw/ calibrationE = 140 V/cmE = 230 V/cm

6. 29/05/2018dE/dx with resistive Micromegas6No significant dependence on drift distance observed (B=0 data)Drift, cmResolutionDrift, cmE = 140 V/cmE = 230 V/cm

7. 29/05/2018dE/dx with resistive Micromegas7rowDrift (cm)No dependence on drift distance observedB= 1T Data

8. 29/05/20188Charge per rowData samples taken in 2015Some pads were disconnected  exclude them from PID studydE/dx with resistive Micromegas

9. 9Cross check of the dead pads with the variation of the beam positiondead pads29/05/2018dE/dx with resistive Micromegas

10. 29/05/2018dE/dx with resistive Micromegas10Apply multi-module selection (one long track across 3 modules)Vary to reach the best resolution : =0.7Use 20+19+21=60 rows, 42.5 cm , which corresponds to , for the full length (8 modules) RESULTS truncation parameter) dE/dx resolution

11. 29/05/2018dE/dx with resistive Micromegas11The dE/dx resolution for the ILD TPC track length (8 modules of 24 rows) is 5.0 % -> no significant degradation by the resistive foilStudy the dependence of the resolution on the drift distance, energy, peaking time, was performed: no dependence is observed 230 V/cm field is slightly better than 140 V/cmTo be studied: correlation between rows (due to transverse diffusion or charge spreading) might increase the dE/dx uncertainty and affect the L-0.5 track length dependence of the resolution. CONCLUSIONS