LEED Credits Recycled Content  Waste Recycled Regional Rapidly LowEmitting Daylight Acoustical LEED Credits Recycled Content  Waste Recycled Regional Rapidly LowEmitting Daylight Acoustical

LEED Credits Recycled Content Waste Recycled Regional Rapidly LowEmitting Daylight Acoustical - PDF document

giovanna-bartolotta
giovanna-bartolotta . @giovanna-bartolotta
Follow
654 views
Uploaded On 2015-01-15

LEED Credits Recycled Content Waste Recycled Regional Rapidly LowEmitting Daylight Acoustical - PPT Presentation

Assemblies available to meet STC and IIC requirements Accepts Type F and Type G light fixtures Assembly selector with downloadable revit files available at usgdesignstudiocom Options available for severe environmental conditions ICCES evaluated appr ID: 31584

Assemblies available meet

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "LEED Credits Recycled Content Waste Rec..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

USG DRYWALL SUSPENSION SYSTEM FLAT CEILINGS FEATURES AND BENEFITS Installs faster than traditional framing methods.More than 60 UL re-resistive designs. Assemblies available to meet STC and IIC requirements.Easily frames openings for Type F and Type G light xtures. Evaluated for building code compliance according to ICC ESR-1222. 1 1 / 2 " USG Drywall Suspension System/USG Sheetrock® Brand Gypsum Panels USG Ceiling Solutions YEAR LIMITED SYSTEM WARRANTY• No Visible Sag• Mold/Mildew Protection USG DRYWALL SUSPENSION SYSTEM FLAT CEILINGSThe trademarks USG, CGC, COMPÄSSO, FIRECODE, SHEETROCK,IT’S YOUR WORLD. BUILD IT., the USG/CGC logo, the design elementsand colors, and related marks are trademarks of USG Corporationor its aliates. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specication and installation. Rated Load ASTM ClassLengthHeightItem No.Fire RatingIBC Seismic DesignHanger Spacing–lb./LF24"36"48" L/240L/360L/240L/360L/240L/360SYSTEM COMPONENTSStraight Main Tees DGLW 15/8"nom. 1 1 / 2 " Heavy Duty12'1.617"DGLW26DGLW26E(G90) A-F129Wall-to-Wall System Straight Tee** DGW 15/8"nom. 1 1 / 2 " Heavy Duty6' to 14'1.617"DGW26sClass AA-F131Span L/360 lb./LFSpanValueCross Tees DGLW 1 1 / 2 " 11/2" 1-1/2"DGLW224 A-F24"99.926"1-1/2"DGLW2624 A-F26"93.11-1/2"DGLW424DGLW424E (G90) A-F48"15.950"1-1/2"DGLW50 50"14.172"1-1/2"DGLW624 72"4.7 DGW     1.617"DGW-6026DMDGW-7226DMDGW-8426DMDGW-9626DMClass AA-F60"72"84"96"Moldings 1" 11/2" 12'DGWM24DGWM24EA-F 1 1 5/8" 12'DGCM27EA-F      12'DGLC-12A-F AccessoriesDGSC180 Splice Clip*DGTC90 Transition ClipDGC4, DGC6, DGC8 USG Compässo™ Drywall ClipDGWC Wall Attachment ClipCMAC-1 Close Mount Attachment Clip        * See AC3152 for alternative splice details ** See AC3230 for expanded wall-to-wall data Firecode®PHYSICAL DATA/FOOTNOTESProduct literature and samplesData sheet: AC3117Data sheet wall-to-wall: AC3230Samples: 257202Direct mount install guideMaterialMin. G40 hot-dipped galvanized steel.G90 hot-dipped galvanized steel available for select items.Online toolsusgdesignstudio.com or cgcdesignstudio.comInstallationInstall according to ASTM C636, ASTM E580, ASTM C754 CISCA and USG requirements. Alternate installation methods may be used when approved by the authority having jurisdiction.LimitationsFor exterior applications, the suspension system should be reviewed by a structural engineer. Please refer to SC2561 for more information about exterior ceiling applications. LA Research Report - RR 25764Refer to usg.com for most current version.ICC Evaluation Services, LLC. Report ComplianceFor areas under ICC jurisdiction, see ICC-ES Evaluation Report ESR-1222 for allowable values and conditions of use. Reports are subject to reexamination, revision and possible cancellation. Refer to usg.com for most current version.Notes1. Manufactured and tested in accordance with ASTM C635, ASTM A653, and ASTM C645.2. Spanning tees for Direct Mount System mfg. with cross tee connection clip at one end and ush-end at other. 3. Products with 'E' in name are made of G90 HDG steel. AC3117/rev. 7-20© 2020 USG Corporation and/or its aliates. All rights reserved.Printed in U.S.A.Manufactured byUSG Interiors, LLC550 West Adams StreetChicago, IL 60661 NoticeThe information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document. Revit is the trademark of Autodesk Inc. ORDERSAMPLES/LITERATUREUSG: samplit@usg.comfax: 888 874-2348 | usg.comCGC: contact Sales Representative TECHNICAL SERVICES800 USG.4YOU (874-4968)FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOLusgdesignstudio.comcgcdesignstudio.com