Team 1 TIA Portal in UAB At the moment support only for S7 1500 PLC series S7 300400 PLCs will be supported in next releases TIA command line interface developed by PCS section 2 Specification File ID: 1015761
Download Presentation The PPT/PDF document "TIA Portal in CPC UCPC" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
1. TIA Portal in CPCUCPC Team1
2. TIA Portal in UABAt the moment support only for S7-1500 PLC seriesS7-300/400 PLCs will be supported in next releasesTIA command line interface developed by PCS section2
3. Specification FileGeneration ToolUser TemplatesInstance GeneratorLogic GeneratorWinCC OA db GeneratorInstance FilesLogic FilesTia Project GeneratorRecomended: Update templatesLogic completion3
4. TIA Portal in UAB: workflow1. Empty project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLC8 Dec 2016TIA Portal in CPC Wizard 1.94
5. TIA Portal in UAB: workflow1. Empty project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLCTake initial empty project containing only hardware & network configuration.5
6. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLCImport tag table (generated .xlsx file) or add tags manually in the project.Tags are „like” symbols – assign names to pieces of memory.However, mapping between block names and numbers is not possible!6
7. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLCImport Sources to „External Sources” folder in the TIA Project structureGenerate blocks from imported sourcesCompile generated blocks7
8. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLCImport Sources to „External Sources” folder in the TIA Project structureGenerate blocks from imported sourcesCompile generated blocks8
9. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLCImport Sources to „External Sources” folder in the TIA Project structureGenerate blocks from imported sourcesCompile generated blocks9
10. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLC10
11. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLCWinCC OA needs to know addresses of communication data blocks......but TIA Portal does not provide any solution to assign them automaticallySolution = TIAcli + mapping file11
12. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLC12
13. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLC13
14. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLC14
15. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLC15
16. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLCTIA Portal project UAB plug-in16
17. TIA Portal in UAB: workflow1. Empty TIA Portal project2. Import tags3. Import Baseline4. Import Instances5. Import Logic6. Generate OBs7. Renumber blocks8. Compile Hardware9. Compile Software10. Load PLC17
18. Future plansAdd support for S7-300/400 PLCsRemove UNICOS-optimisation object blocks for S7-1500 PLCsUse symbolic addressing instead of absolute addressingTurn on memory optimization on the PLC side (S7-1500)Research whether can support S7-1200 PLCsImproving TIAcli using the new openness features18