Performing A Software Update on the IFD Performing A Software Update on the IFD

Performing A Software Update on the IFD - PowerPoint Presentation

jane-oiler
jane-oiler . @jane-oiler
Follow
360 views
Uploaded On 2020-01-10

Performing A Software Update on the IFD - PPT Presentation

Performing A Software Update on the IFD Avidyne Factory Authorized Installation Training 10231 Getting the software 2 Nothing in the following video constitutes an approval to install software on the IFDs ID: 772388

drive software upgrade usb software drive usb upgrade file avidyne running settings update select failure data repair windows ifd

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Performing A Software Update on the IFD" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Performing A Software Update on the IFD Avidyne Factory Authorized Installation Training 10.2.3.1

Getting the software 2 Nothing in the following video constitutes an approval to install software on the IFD’s This software constitutes a “Minor A lteration,” so by FAA regulation (43.3, 43.5 and 43.7) must be “signed off” by an appropriately rated Repair Station / A&P / or IA If this software update is performed by someone other than an Avidyne Authorized Dealer, you should understand: A) If something goes wrong during the update, and the unit needs to be returned to Avidyne for repair, charges will apply, and would be charged in advance B) These charges are NOT covered under Avidyne Warranty C) Advanced exchange and standard exchange will not be an option. Units needing repair under these circumstances will be eligible for repair and return only, which may take up to 10-15 business days for turn time

Effectivity 3

To verify Current Software 4

Load Times 5

Formatting the USB Drive 6 For this software update, a PC with on of the following operating systems is REQUIRED: Windows XP, Windows Vista, Windows 7 or Windows 8 PC with an available USB port. NOTE: MAC/Apple products are NOT compatible A USB Flash Drive of 8GB or 16GB is also required Insert the thumb drive to your PC, and go to “My Computer” Right click on the corresponding drive Select “Format” from the dropdown Under “File System” select FAT32 Put a checkmark next to “Quick Format” and hit “Start” NOTE: Any data currently on the USB drive will be erased, so make sure any important data has been saved elsewhere

Formatting the USB Drive 7

Downloading the software 8 Once you have downloaded the software .zip file, you will need to “Extract” the data. To do this, right click on the 10.2.3.1_Update.zip file and select “Extract All” from the dropdown

Downloading the software 9 Open the folder containing the “Extracted” files. It should look like this:

Downloading the software 10 Select and move all of the files except the Service Bulletin to the USB drive you just reformatted. Click drag and drop the files will prevent the runonce file getting .txt file extension. Open and print out the Service Bulletin Once completed, your USB thumb drive should look like this:

Recording System Settings 11 Maintenance Mode Configuration Settings:

Recording System Settings 12 NOTE: Avidyne will not have any record of how these items are configured. If this data is lost, the unit will have to be configured from scratch.

Upgrading Multiple IFDs 13

Upgrading the IFDs on a bench setup 14

Beginning the upgrade 15

Running the upgrade 16

Running the upgrade 17

Running the upgrade 18

Running the upgrade 19 After hitting “Cancel” to the prompt for backing up the settings/configs Go record all settings and configs IAW section 2.2.1 Once all settings/configs are recorded the following will restart the software load at the point where it was previously canceled out:

Running the upgrade 20

Running the upgrade 21

Post accomplishment 22

Post accomplishment 23

In the event of a failure 24 If the IFD has passed everything up to the “Conformity” test, and you see this error: This indicates the “Create Gold Master” file has not run. Toggle off the “Update” tab, then back to it. Select ONLY “Create Gold Master” and hit “Proceed” This should correct the issue.

In the event of a failure 25 Snap a picture of the failure screen on the IFD DO NOT power off the unit! DO NOT remove the USB drive! Email the photo of the failure screen to techsupport@avidyne.com and put “IFD Failure” in the subject line Include a name, a good phone number, and what step of the Service Bulletin you’re on, and someone from tech support will call you ASAP (M-F, 8-5 Eastern Time).