Download Pdf The PPT/PDF document "Operator" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Operator’s Manual Installation Instructi
Operator’s Manual Installation Instructions M / XL KACO new energy 3 Operator’s Instructions KACO-proLOG1 About this document The following information will guide you through the entire operator’s manual. Further documents will be valid in conjunction with these operating and installation instructions. We shall not be liable for any damage caused by non-adherence to the instructions given in this manual. 1.1 Pertaining documents During the installation o

f the data logger please observe all ass
f the data logger please observe all assembly and installation instructions for components and other parts of the system. These instructions are shipped together with the respective installation components or supplementary equipment. 1.2 Attachment and Maintenance of documents Please keep these operating and installation instructions in a safe place to ensure that they are available if needed. 1.3 Symbols used in this document Please observe the safety information provided in this manual when operating your inverter! Note! Useful information and remarks! Important1.4 UL Certificat

ion CE labeling is used to document tha
ion CE labeling is used to document that the KACO data logger indicated on the type label meets the fundamental requirements according to UL requirements. 1.5 Type Label The type label indicating the exact device designation is located on the right side of the housing. 2 Safety Information The data logger system for photovoltaic installation must only be connected by authorized skilled personnel. Always make sure that leads and cables do not carry hazardous live voltages before routing or establishing connections.. Operators must read this manual carefully and familiarize them

selves with the device prior to putting
selves with the device prior to putting it into operation. All local regulations and provisions must be observed when operating this device. Damaged instruments must be made inoperable immediately and/or checked by authorized skilled personnel. Manipulating or modifying the devices/instruments is not permissible. Opening the device is not permissible. The safety of the device and operator will no longer be ensured if the device is not operated according to the safety instructions stated in this manual. The proper and safe operation of the device/instrument requires proper transporta

tion, storage, erection and assembly, as
tion, storage, erection and assembly, as well as careful operation and maintenance. 2.1 Transportation The KACO-pro data logger is subjected to extensive testing and inspection in our test field, so as to ensure the superb quality of our products. Our data loggers leave our factory in a proper electrical and mechanical condition. Special packaging ensures that nothing can happen during the transport to our customers. Nevertheless, transport damage may not be ruled out completely. In this case, the forwarding agent/carrier will be responsible. Please check the data logger carefully o

n arrival. Should you discover any visib
n arrival. Should you discover any visible signs of damage on the packaging, which imply that the data logger may be damaged, or should you find any visible signs of damage on the data logger itself, please notify your responsible forwarding agent/carrier immediately. KACO SOLAR INC. will provide assistance as necessary. However, INVitten damage reports must be received by the forwarding agent within six days after receipt of the goods at the latest. Use exclusively the original packaging for returning the data logger – only this material will ensure safe transportation. Caution! Pot

ential hazard for the product and envir
ential hazard for the product and environment! KACO new energy 9 Operator’s Instructions KACO-proLOG5.3.3 Structure of the display menu KACO new energy 11 Operator’s Instructions KACO-proLOGInstallation/Plant The “Power/Energy” field shows the total output of the plant as well as the energy delivered over various different periods o

f time. The “Alarms/Errors” field provi
f time. The “Alarms/Errors” field provides messages about recognized system errors. Energy DI If at least one digital channel is selected to calculate the total output of the installation the respective measuring data will be displayed in the following sub-menus: Latest Output Daily energy yield Previous day’s energy yield Monthly energy yield Annual energy yield Total energy yield Inverter energyinverters are selected for the calculation of installation output and energy yield, the respective values will be displayed in the following submenus: Latest output Daily energy yield

Previous day’s energy Monthly energy yi
Previous day’s energy Monthly energy yield Yearly energy yield Total energy yield Alarms/errors Communication: Error during modem connection buildup System: A system error has occurred. Measuring channels: Error during the detection of measuring channels. Set pasword as 0030 to use a KACO-web plant. KACO new energy 14 Operator’s Instructions KACO-proLOG6.3.1 Windows 95/98 Step 1Select “START / PROGRAMS / ACCESSORIES / COMMUNICATION“ to access

the menu item “Network Connections.” St
the menu item “Network Connections.” Step 2Select “Establish new connection” and assign a name to the new connection to be established. In addition, enter the modem you wish to use for this connection. (A suitable modem must be connected to your PC and installed). If KACO-prois equipped with an internal analog modem, an analog modem or ISDN modem with analog simulation must be used for communication. If KACO-is equipped with an internal ISDN modem, the PC must likewise be equipped with an internal ISDN modem for communication. Step 3Click “NEXT” to set up your connection. Use the

“GENERAL” tab to enter the phone number
“GENERAL” tab to enter the phone number of the line you wish to communicate with LOGAll other settings already exist as defaults and do not need to be changed. Please note that an external call prefix may be necessary when entering the telephone number. In most cases, this external call prefix will be assigned a preceding “0”. KACO new energy 16 Operator’s Instructions KACO-proLOG6.3.2 Windows 2000 Step 1 Click “START / PROGRAMS / ACCESSORIES / COMMUNI

CATION“ to access the menu item “(Networ
CATION“ to access the menu item “(Network and Remote Communication).”Activate this menu item to open the “DFÜ Network” dialog. Step 2Select “Establish new Connection” and assign a name of your choice to the new connection to be established. In addition, enter the modem you wish to use for this connection. (A suitable modem must be connected to your PC and installed). If KACO-prois equipped with an internal analog modem, an analog modem or ISDN modem with analog simulation must be used for communication. If KACO-is equipped with an internal ISDN modem, the PC must likewise be equipped

with an internal ISDN modem for communic
with an internal ISDN modem for communication. Step 3Click “PROCEED“ or set up your connection. Use the “GENERAL” tab to enter the phone number of the line you wish to communicate with LOGAll other settings already exist as defaults and do not need to be changed. KACO new energy 17 Operator’s Instructions KACO-proLOGPlease note that an external call prefix may be necessary when entering the telephone number. In most cases, this external call pre

fix will be assigned a preceding “0”. St
fix will be assigned a preceding “0”. Step 4Double-click the new connection to open the “Connect to” dialog. Click the “Connect” button to initiate the dialing process. “Admin” must be entered as the user name and password. [ w ], [ , ] and blank characters between the digits of the telephone numbers are commands for the telephone system (wait until externall call prefix is established). More detailed information is given in the description of the telephone system In the dialog “Connect to KACO-LOG”, click(Features) to open another window. Highlight [Internetprotokoll (TCP/IP)] and

click (Features). In the new dialog (F
click (Features). In the new dialog (Features of Internet Protocol TCP/IP), highlight the (Use the following IP address) and enter the IP address 192.168.200.51. Enter 1.0.0.0. for [DNS-Server]. KACO new energy 23 Operator’s Instructions KACO-proLOG7.2 Online values This field shows various measuring values of the sensors and meters/counters connected to the analog and digital inputs. If inverters are connected to the RS485 interface, you will also

be able to poll the inverter values. 7.
be able to poll the inverter values. 7.2.1 Analog/Digital Inputs Sum of Selected Digital Inputs Designation Unit Designation Current power: 0.000 kW Current monthly energy yield: 0.000 kWh Current daily energy yield: 0.000 kWh Current annual energy yield: 0.000 kWh Previous day energy yield: 0.000 kWh Total energy yield 0.000 kWh Example:The plant consists of two sub-sections which have separate meters connected to KACO. To obtain correct sums you must activate these two separate meters under “Admin – Measurement” �- Energy – Digital Channels”. Details of digital

inputsInput Details Channel Design
inputsInput Details Channel Designation Value Minimum Maximum Unit Meter Unit 1 Meter 1 0.000 0.000 0.000 kW 2.041 kW 2 Meter 2 0.000 0.000 0.000 kW 2.040 kW 3 Meter 3 0.000 0.000 0.000 kW 2.040 kW 4 Meter 4 0.000 0.000 0.000 kW 2.050 kW This box shows the measured values separately for each digital input. Current outputThe metering pulses are converted to the respective output value (display in kW) by means of a pulse constant. MinimumShows the smallest measured value of the current day. MaximumShows the greatest measured value of the current day. Meter countSh

ows the total sum of measured pulses. Th
ows the total sum of measured pulses. This display can be compared/aligned to the actual value of the energy meter (see menu item “Admin – Measurement -� Digital Channels“; display in kWh). Details – analog inputsDetails Analog Inputs: Channel Designation Minimum Maximum 1 Free - - - - 2 Free - - - - 3 Free - - - - 4 Free - - - - The analog values are listed along with the channel number and description; the following information is provided: ValueCurrent online value (updated every 10 seconds) This field gives you a summary of the total energy output of a plant.

Use “Admin Measuremen�t - Energy
Use “Admin Measuremen�t - Energy – Digital Channels “ to determine the calculation of this total sum. MinimumShows the smallest measured value of the current day. MaximumShows the greatest measured value of the current day. KACO new energy 25 Operator’s Instructions KACO-proLOG 7.3.2 Inverters Failure messages provides information about the last alarm message, recipient of this alarm message and send type. Quick Info summarizes all the connected in

verters, including their addresses and d
verters, including their addresses and device statuses. 7.4 Configuration 7.4.1 Plant data Plant data will be needed at different points – LOG needs this information on the first page (start page), i.e. to obtain a quick overview of the system. To enable the definition of failure messages the “plant data” information is available in the field “Admin – Monitoring / Formulas.” This field allows entering information about the plant operator, plant capacity, module types, orientation, etc.,and concerning the transmissionof error messages, scan rate, etc. Plant designation: This entr

y appears on the start page and is displ
y appears on the start page and is displayed for all alarm messages. Operator: For documenting purposes only. Installed power: This parameter is used to calculate alarm criteria. Module area: Used for calculating alarm criteria. Module efficiency: Used for calculating the alarm critera. Inverter efficiency: Used for calculating the alarm criteria Number of subsystems: Used for calculating the alarm criteria Storage interval: Data compression to 300, 600, 900, 1800, 3600 sec Orientation: Provides information about the orientation of the installation (e.g. towards the S

outh) Inclination: Refers to the (angl
outh) Inclination: Refers to the (angle of) inclination of modules Module type: Module data Inverter type: e.g. KACO 5000xi Email contact for data transfer: shows the destination (recipient) of read data External call prefix: Used to enter the digit of the external line (this depends on the type of telephone installation) Dial tone or pulse dialing Used to select the dialing method Timeout (analog modem): Sets the max. time allowed between two bell signals Language: Allows selecting between German and English Connection Acceptance On / Off: The “connection acceptance” functi

on of the data logger may be restricted
on of the data logger may be restricted to a certain period of time. More detailed information is given on the next page. Bell signal (analog modem): Defines the number of bell signals until KACOproLOG responds Contact for daily file transfer via fax: Daily files can additionally be sent by fax at a defined hour. Possible options: Inactive, contact 1-4, standard contact. KACO new energy 27 Operator’s Instructions KACO-proLOG7.5 Admin - Monitoring 7.5.1 Net

work The Network field is subdivided int
work The Network field is subdivided into 4 sub-fields. 1. SettingsThe settings refer to the network settings for the web server of KACO-IP Server Address IP address of KACO-LOG after dialing in by modem / ISDN /GSM (standard setting: 192.168.200.1). network mask of the server: Do not change. Caller IP AddressDo not change. (Standard setting: 192.168.200.51 Server Telephone NumberThis phone number is used for documenting purposes only; it shows the number at which KACO-proLOG can be reached. Lan-Interface settings (Ethernet)These settings refer to the local network settings of LOGCur

rent IP AddressShows the current IP addr
rent IP AddressShows the current IP address of KACO-proBoot ProtocolSelectable between none, DHCP, BOOTP, RARP. A description of protocols is given on page 10.Static IP addressUsed to enter the desired IP address, if no boot protocol is used. Network MaskThis field defines the network mask to be used, if no other network mask is assigned by the BOOTP or DHCP server. GatewayDefines the gateway, if no other gateway is assigned by the BOOTP or DHCP server. 1st DNS serverUse this field to enter the DNS server. 2nd DNS serverUse this field to enter an alternative DNS server. The ISDN Ter

minal adapter settings refer to the ISDN
minal adapter settings refer to the ISDN settings of KACO-LOG. If the device is to be used at ISDN extension you must enter the appropriate extension number. Number of the ISDN extension – usually a phone number without area code. The settings under Check of message pathsare used to test if KACO proLOG has connected successfully. This option allows checking the contacts by made email, fax and SMS. Test ContactThis field is used to enter the contact person to receive the test message. You may either select the standard contact or one of four contact addresses. To select the type of co

ntact (by email, fax or SMS), simply ena
ntact (by email, fax or SMS), simply enable the appropriate checkbox with a tick mark. Changes will not be active until the “Save” button is pressed. 2. Internet This field is used to set the Internet access points (provider) used by KACO-proLOG to log into the Internet. You must enter the description, dial-in number, user name and password. Providers are listed under “Network� - Email“. Changes will not be active until the “Save” button is pressed. 3. Email Used to enter the settings required to send emails. The SMTP server (outgoing mail) setting defines information conc

erning IP address and email address. The
erning IP address and email address. These entries are mandatory if KACO-proLOG is to send emails. IP address of serverIndicates the IP address of the email server to be logged into. The IP address of our computer center is 213.179.128.176. KACO new energy 33 Operator’s Instructions KACO-proLOG8.3.1 Basic principle of monitoringThis example is based on the physical ratio between the solar radiation (insolation) and the generated power; under ideal conditio

ns, this ratio would be as follows: [gen
ns, this ratio would be as follows: [generated power] = [Insolation * AreaModule Moduleeta inverter Assuming a PV module having a degree of efficiency of 12%, an inverter efficiency of 91% and a module area of 10 square meters, the ideal ratio is shown in the graph below: 0,10,20,30,40,50,60,70,80,91,1010020030040050060070080090010001100Einstrahlung in [W/m²]Leistung in [kW]Pac = Gmod * eta mod * eta WR * FlächeAs in reality this ratio is not exactly linear over the entire range (smaller amount of solar radiatio�n = lower degree of efficiency), a solution must be found to ob

tain a functional error messaging criter
tain a functional error messaging criterion. We are therefore “opening up” a range in which two read values can occur. This requires two formulas for calculating straight curves, which form the upper and lower limits of a “plausible” range. -0,4-0,20,20,40,60,81,21,401002003004005006007008009001000Einstrahlung in [W/m²]Leistung in [kW]idealGrenze untenGrenze obengültiger BereichStörmeldung:obere GernzüberschreitungStörmeldung:untere GernzüberschreitungTo gain more freedom and flexibility when selecting a range, two different gradients can be defined. The shift of the straight

line by tupper and tlower is to be defin
line by tupper and tlower is to be defined as an absolute value (e.g.: 0.2kW). The limiting lines are now defined by the following formulas: Lower limit: nennWRPVArryModulePtloweretaetaAGmlowerPacUpper limit: nennWRPVArryModulePtupperetaetaAGmupperPacWith: mlower = 0.85 tlower = - 0.25 mupper = 1.1 tupper = 0.15 8.3.2 Parameterization of the measuring device Settings via the menu item: “Admin – monitoring – formulas / criterion X”: First the general definitions are determined for this alarm parameter: Designation: “Power generated by solar insolation”

Status: “active“ Time: “Interval“ Alar
Status: “active“ Time: “Interval“ Alarm target (contact) “Standard contact“ Type of message: E-Mail Delay: “8“ (triggering an alarm delay of 2 hours at a measuring interval of 2 hours). To send an alarm message the contact must be defined in the menu under: [ Admin – Monitoring / Contact addresses / contact x ] ! Then the formula entries are as follows: Y Generation PVA m (lower limit) 0.85 m (upper limit) 1.1 x Insolation module (ana_0);plant surface; * ;etaPV;*;etaINV;* c (lower limit) 200 c (upper limit) 200


KACO new energy 34 Operator’s Instructions KACO-proLOG8.4 Programming criteria based on the example of an inverter comparison In this example the daily yield of INV4 is compared to that of INV5 and in case of a power anomaly an alarm will be activated. Varios kinds of inverters can be compared. Please create relations in the settings and activate the criteria. Then enter if you wish to calculate the criterion at each logging interval or once per day. In the field “formula settings”, e

nter the daily yield abbreviation of the
nter the daily yield abbreviation of the respective inverter under x,y. (In our example this is EINV_3, E_INV4). The shift of addresses results from the fact the proLOG addresses start with “0” (daily energy of INV 5 EINV_4). This value is subsequently divided by the installed generator capacity, thus allowing a comparison of the values of different inverters. The upper and lower limits can be set under item c; the gradient is set under item m. The gradient may remain unchanged in most cases.

KAC
KACO new energy 36 Operator’s Instructions KACO-proLOG10 Technical data Ambient temperatures Operation: 32°F to +131°F Storage and transport: -4°F to +149°F Electrical Data Voltage supply: 110 Vac Analog inputs: 0 Vdc to 10Vdc / PT-1000 Resistance measurement: (configurable) Digital inputs: Low = 0 Vdc to 7 Vdc High = 9 Vdc to 24 Vdc Voltage input: 0.5% of input value (EW) Current input: 1% of input value (EW) Interface 1: PSTN connection External modem ISDN connection Interface 2: Ethernet connection

Interface 3: RS – 485 Mechanical Da
Interface 3: RS – 485 Mechanical Data Dimensions (WxHxD): 230 x 225 x 85mm Installation: Wall - mounted Protection Class: IP21 Weight: 1 kg A lithium cell of the type Li2032 is used as battery. This battery can be stored for more than 10 years. The battery life (if the battery is inside the device) is longer than 5 years. Battery change by unsoldering/soldering at the manufacturer’s site. Alarm options of the various modem typesAlarm via email Direct connection to the PC only possible via network card. Alarm via email, sms Direct connection to the PC onl