/
Endovascular AAA Dr. Sal Scali, University of Florida, Gainesville Endovascular AAA Dr. Sal Scali, University of Florida, Gainesville

Endovascular AAA Dr. Sal Scali, University of Florida, Gainesville - PowerPoint Presentation

quinn
quinn . @quinn
Follow
66 views
Uploaded On 2023-12-30

Endovascular AAA Dr. Sal Scali, University of Florida, Gainesville - PPT Presentation

Deidentified case review IRR variable variation discussion General Q amp A for EVAR Agenda Independent audit Please do not ask for any help from anyone ie other data abstractorsphysicians ID: 1035942

leave blank select open blank leave open select unfit iliac type max branch repair left diameter unknown aneurysm sac

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Endovascular AAA Dr. Sal Scali, Universi..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1. Endovascular AAADr. Sal Scali, University of Florida, Gainesville

2. De-identified case reviewIRR variable variation discussion General Q & A for EVARAgenda:

3. Independent audit: Please do not ask for any help from anyone (i.e. other data abstractors/physicians/etc). No dates includedInstructed if they could not find a data element, it was ok to leave it blank and submit without validation Limitations of the IRR project:

4. Total fluoroscopy time during the index procedure.Min/max range: 1 to 300 minutes Q1: Fluoroscopy Time

5. 4.54040.340.32 40.540.5341OtherUnknown (leave blank) Select A1: Fluoroscopy Time

6. 4.54040.340.32 40.540.5341OtherUnknown (leave blank) A1: Fluoroscopy Time

7. Any Intraoperative EndoleakProximal(Ia) = Proximal attachment site [type Ia];Distal Right (Ib) = Distal attachment site right iliac [type Ib];Distal Left (Ib) = Distal attachment site left iliac [type Ib];Lumbar Branch (II) = Lumbar branch [type II] retrograde filling of sac via lumbar artery;IMA Branch (II) = IMA branch [type II] retrograde filling of sac via inferior mesenteric artery;Accessory Renal Branch (II) = Accessory renal branch [type II] retrograde filling of sac via accessory renal artery;Mid Graft Separation (III) = Mid-graft separation [type III] = Filling of sac via leak at limb overlap sites or limb separation;Midgraft Fabric Hole = Mid-graft fabric hole [type III] = Filling of sac via hole in graft fabric;Indeterminate = Endoleak seen but type is not certain.Q2: Intra Op Endoleak

8. NoYesUnknown (leave blank)Select A2: Intra Op Endoleak

9. NoYesUnknown (leave blank)A2: Intra Op Endoleak

10. Most recent left ventricular ejection fraction (%), by Echo, nuclear scan, or cath estimate, within 6 months;If none within 6 months, choose not done;Choose unknown if it is not known whether a test was done, or if the result cannot be determinedQ3: Ejection Fraction

11. <30%30-50% >50%Not DoneUnknown (leave blank)Select A3: Ejection Fraction

12. <30%30-50% >50%Not DoneUnknown (leave blank)A3: Ejection Fraction

13. Endovascular repair performed because patient was considered too high risk by surgeon for open repair, i.e., mandatory endovascular repairQ4: Unfit for Open Repair

14. NoYesUnknown (leave blank)Select A4: Unfit for Open Repair

15. NoYesUnknown (leave blank)A4: Unfit for Open Repair

16. List reasons the surgeon considered the patient unfit for open surgeryThis field is required if Unfit for Open AAA Repair is [Yes]Q5: Reason Unfit for Open

17. CardiacPulmonaryFrailtyHostile AbdomenNot Unfit for Open (so question not asked) Select A5: Reason Unfit for Open

18. CardiacPulmonaryFrailtyHostile AbdomenNot Unfit for Open (so question not asked)Select A5: Reason Unfit for Open

19. Aneurysm defined as Iliac diameter at least 2.0 cmQ6: Iliac Aneurysm

20. NoRightLeftBilateralUnknown (leave blank) Select A6: Iliac Aneurysm

21. NoRightLeftBilateralUnknown (leave blank) A6: Iliac Aneurysm

22. Adjunctive procedure performed to facilitate delivery of the endovascular devicesQ7: Left Iliac Adjunct

23. NonePTAStentStent GraftOther Unknown (leave blank)Select A7: Left Iliac Adjunct

24. NonePTAStentStent GraftOther Unknown (leave blank)A7: Left Iliac Adjunct

25. Use max diameter measured at right angle to centerline. If not possible, use max AP diameter. If multiple imaging modalities, use most accurate in following hierarchy:CT>MRI>Ultrasound>arteriogramMin/max range: 20 to 150 mm Q8: Max AAA Diameter

26. 52 57OtherUnknown (leave blank) Select A8: Max AAA Diameter

27. 52 57OtherUnknown (leave blank) A8: Max AAA Diameter

28. Maximum angle between axis of suprarenal aorta and aneurysm neck, optimally measured with 3-D CT imaging softwareQ9: Aortic Neck Angle

29. < 45 Degrees45-60 Degrees61-75 Degrees76-90 Degrees90 Degrees Unknown (leave blank)Select A9: Aortic Neck Angle

30. < 45 Degrees45-60 Degrees61-75 Degrees76-90 Degrees90 Degrees Unknown (leave blank)A9: Aortic Neck Angle

31. Questions