/
www.Fisher.comFisher Specification Manager www.Fisher.comFisher Specification Manager

www.Fisher.comFisher Specification Manager - PDF document

sherrill-nordquist
sherrill-nordquist . @sherrill-nordquist
Follow
409 views
Uploaded On 2016-04-15

www.Fisher.comFisher Specification Manager - PPT Presentation

Fisher Specification ManagerDecember 2012 Fisher Specification ManagerDecember 2012General Overview3Software Installation4Installation From Emerson External Website4Launching the Application for the F ID: 280911

Fisher Specification ManagerDecember 2012 Fisher Specification

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "www.Fisher.comFisher Specification Mana..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

www.Fisher.comFisher Specification Manager Fisher Specification ManagerDecember 2012 Fisher Specification ManagerDecember 2012General Overview3Software Installation4Installation From Emerson External Website4Launching the Application for the First Time8More Important Features20Duplicate20Save Projects & Save Projects As21Compare21Cv Plot22Next Tag & Previous Tag22Save As Template23Help & About23Drawings23Report Generation Process24Profile Features25User Profile25Project Profile26Update your Software27 Fisher Specification ManagerDecember 2012GENERAL OVERVIEWEnabling engineers to be more productive at control valve sizing & selection.Create an ISA specification sheet with ease using Fisher Specification Manager software. Simply navigate through theIts All About EfficiencyConvenient hot buttons and rightclick options provide quick access to view Cv plots and create new projects, tags, Fisher Specification ManagerDecember 2012SOFTWARE INSTALLATIONInstallation From Emerson External Website Fisher Specification ManagerDecember 2012 Fisher Specification ManagerDecember 2012 7. Once the download has completed, select Run on the below dialog box. Fisher Specification ManagerDecember 2012 Fisher Specification ManagerDecember 2012Now that your Fisher Specification Manager installation is complete, you will need to learn how to navigate 3. We will want to size a valve for this project, therefore we need to CREATE a New Project by clicking the Project 4. A project folder will appear within the Tree View on the left hand side of the screen. At this point you can modifythe Project Name (e.g. Project1Ž) if you like. For this samples purpose, we will leave it as Project1Ž, and click theNew TagŽ button just to the right of the New ProjectŽ button. You can also rename the Tag to something more Fisher Specification ManagerDecember 2012 a. Style GlobeŽb. Rating CL300Žc. Nominal Inlet Pipe Size 2Žd. Nominal Outlet Pipe Size- 2Že. End Connection RF FlgŽf. Insulation NoneŽg. Allowable Noise 90Žh. Body to Bonnet bolt & nuts material Manufacturer StandardŽi. Packing Flange Studs & Nuts Manufacturer StandardŽj. Design Pressure 100Ž, psigŽk. Design Temperature 60Ž, deg FŽl. ANSI Shutoff- ANSI CL IIŽm. Service Description Service Description SampleŽ Fisher Specification ManagerDecember 2012 Long NamesOthersŽ. These are call (also known as Sizing or Process Conditions). Under the Žcolumn, make sure the values look as follows: a. Gasb. Mass Flow Rate Gas lb/hŽc. Inlet Pressure psigŽd. Pressure differential psiŽe. Inlet Temperature deg FŽf. Molecular Weight / Specific Gravity SGŽg. Kinematic viscosity cStŽh. Ratio of specific heatsi. Inlet Compressibility Factorj. Pressure Drop ratio factor (xt)k. Recovery Factor (Fl) Fisher Specification ManagerDecember 2012l. Valve style modifier (Fd)m. Upstream pipe size inŽn. Upstream pipe scheduleo. Downstream pipe size inŽp. Downstream pipe scheduleq. Valve Diameter inŽr. Valve/Trim for aerodynamic noises. Aerodynamic distance Rn ftŽt. Valve Outlet Area in2Žu. Outlet temperature deg FŽv. Outlet Compressibility Factora. Gas AIRŽb. Mass Flow Rate Gas 15000Žc. Inlet Pressure 100Žd. Pressure differential 101Že. Inlet Pressure 102Žf. Molecular Weight / Specific Gravity 1Žg. Kinematic viscosityh. Ratio of specific heats 1.4Ži. Inlet Compressibility Factor 0.01Žj. Pressure Drop ratio factor (xt) 0.65Žk. Recovery Factor (Fl) 0.9Žl. Valve style modifier (Fd) 0.35Žm. Upstream pipe size 2Žn. Upstream pipe scheduleo. Downstream pipe size 2Žp. Downstream pipe scheduleq. Valve Diameter 2Žr. Valve/Trim for aerodynamic noise Globe/AngleŽs. Aerodynamic distance Rn 5Žt. Valve Outlet Area 6Žu. Outlet temperature 7Žv. Outlet Compressibility Factor 8Ž Fisher Specification ManagerDecember 2012 Paste Condition To AllŽ. This will paste all yourŽ. A list of Valve products will be listed in the top pane of theform.Ž.17. Click the plussign to the left of Equal Percent:data within the bottom pane of the form. Fisher Specification ManagerDecember 2012 dropdown box. Select Cast IronŽ fromthe grid, and click OK. 22. Click the OptionsŽ button to the right of the click OK.23. Click the OptionsŽ button to the right of the  Fisher Specification ManagerDecember 2012 26. Lets move on to Actuator Sizing by click the  a. Type Spring & DiaphragmŽb. Spring action/fail mode OpenŽc. Hand Wheel Side MountedŽd. Note Actuator Note SampleŽ Fisher Specification ManagerDecember 2012 The Actuator Sizing screen Fisher Specification ManagerDecember 2012a. Operating Range(std) 033 psiŽb. Pa 0.00ŽpsigŽc. Pb 33.00ŽpsigŽd. Valve Body Size 2.0ŽinŽe. Port Diameter 1.3125ŽinŽf. Unbalanced Area 0.16Žin2g. Valve Travel 0.75ŽinŽh. Valve Stem Size .5ŽinŽi. Valve Friction 230.00ŽlbfŽj. Additional Friction 0.00ŽlbfŽk. Seat load force 5.000Žlbf/inŽl. P1 Max 100.000ŽpsigŽm. P2 Min 0.00ŽpsigŽn. Unbal Frce @ Open 0.00ŽlbfŽo. Fluid Neg. Gradient 0.000ŽinŽp. dP Flowing 0.00ŽpsiŽq. With Side MO YesŽ a. Type PneumaticŽb. Manufacturer FisherŽc. Model 3582Žd. Positioner Input Signal Foundation FieldbusŽe. Positioner Action DirectŽf. Gauges- YesŽg. Hazardous Area ASME ApprovedŽh. Note Positioner Note SampleŽa. Manufacturer FisherŽb. Model i2P100Žc. Output 018 psiŽd. Note IP Transducers Note SampleŽ Fisher Specification ManagerDecember 2012a. Manufacturer FisherŽb. Model Mfg. StandardŽc. Air Set Pressure 60Žd. Gauges YesŽe. Note Air Set Regulator Note SampleŽ 40. Populate the Solenoid Valve frame with the following data:a. Manufacturer- ASCOŽb. Model 55102025Žc. Bug Vent Required YesŽd. To VentActuator EnergizeŽe. Voltage 110 VDCŽf. Material BrassŽ Fisher Specification ManagerDecember 2012a. Type MechanicalŽb. Manufacturer WestLockŽc. Model 7313524A2Žd. Contacts Form SPSTŽe. Actuation Points 1 OpenŽf. Current Rating 1ŽAŽg. Voltage Rating 2ŽVŽh. Frequency 3ŽHzŽi. Note Limit Switches Note SampleŽ 44. The whole point of filling out all of these tabs is to generate an overall summary of your valve that you sized, and Fisher Specification ManagerDecember 2012Here is a screen shot of what your ISA Sheet should look like: Fisher Specification ManagerDecember 2012More Important Features RESULT Fisher Specification ManagerDecember 2012 Fisher Specification ManagerDecember 2012 Fisher Specification ManagerDecember 2012 Fisher Specification ManagerDecember 2012menubar. The Select Drawing dialog window will appear. Select the first row of the grid, and click the View DrawingŽ Report Generation Process 3. The Reports dialog window will appear. Click a check mark in the following checkboxes.a. DataSheetb. Valve Sizing Calculationc. Project Summary Fisher Specification ManagerDecember 2012 Profile Features Fisher Specification ManagerDecember 2012 of the time when youre sizing a valve (within the Valve Sizing tab). We will not utilize the Edit Pull DownsŽ for thisProject Profile1. This feature is project specific. Click ProfileŽ on the menubar to expand the submenu, and select ProjectŽ. you entered in the Project Profile setup.4. Also, if you generate a DataSheet, Valve Sizing Calculation, and/or Actuator Sizing Calculation report, the 4heading lines that you entered will show up there. Fisher Specification ManagerDecember 2012Update Your Software 3. Similar to the full installation of Fisher Specification Manager, click RunŽ to both messages that appear during thedownload process. NOTE: This requires you to have installation privileges. If you do not have installation privilegesplease click SaveŽ to the messages and have a system administrator perform the installation for you. Fisher Specification ManagerDecember 2012 Emerson Process Management 2010, 2012 Fisher Controls International LLC. All rights reserved.