Download Pdf The PPT/PDF document "V4T2118Volume 4132Circuit ProtectionCA08..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
1 V4-T2-118Volume 4Circuit Protectio
V4-T2-118Volume 4Circuit ProtectionCA08100005EAugust 2016www.eaton.com Molded Case Circuit BreakersSeries CIndustrial Circuit BreakersG-FrameNotesN.I.T.U. is non-interchangeable trip unit and I.T.U. is interchangeable trip unit.Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250 Vdc.Single-pole breakers can be applied in DC systems up to 70 A.CircuitBreakerTypeContinuousAmperePolesVoltsType of Trip Specification W-C-375bUL Listed Interrupting Ratings (rms Symmetrical Amperes)ACDCAC (kA)DC (kA) 120120/240240277480600125 GHB15 100 1120125N.I.T.U.11a6514V4-T2-126GHB15 1002, 3240125/250N.I.T.U.11a10b, 11b6514V4-T2-126GHB15 1001277125N.I.T.U.12b, 14b1414V4-T2-126GHB15 1002, 3480Y/277125/250N.I.T.U.15b141414V4-T2-126HGHB15 301277125N.I.T.U.12c, 13a, 13b652514V4-T2-126GHBS15 301, 2480Y/277656514V4-T1-34GBHS15 201, 2600Y/347N.I.T.U.10V4-T1-34GDB15 502480125/250N.I.T.U.1410V4-T2-124GDB15 1003480250N.I.T.U.
2 ;1410V4-T2-124GD
;1410V4-T2-124GD15 502480125/250N.I.T.U.13b651410V4-T2-123GD15 1003480250N.I.T.U.13b652210V4-T2-123GHC15 1001120125N.I.T.U.12c, 13a65 14V4-T2-131GHC15 1002, 3240125/250N.I.T.U.13b65V4-T2-131GHC15 1001277125N.I.T.U.12c, 13a1414V4-T2-131GHC15 1002, 3480Y/277125/250N.I.T.U.13b141414V4-T2-131HGHC15 301277125N.I.T.U.652514V4-T2-131 V4-T2-126Volume 4Circuit ProtectionCA08100005EAugust 2016www.eaton.com Molded Case Circuit BreakersSeries C Typical GHB DescriptionPageProduct Overview. . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-116Standards and Certifications. . . . . . . . . . . . . . . . . . .V4-T2-117Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-118G-Frame (15 100 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-121F-Frame (10 225 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-135J-Frame (70 250 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-153K-Frame (70 400 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-161L-Frame (125 600 Amperes) . . . . .
3 . . . . . . . . . . . . .V4-T2-185M-Fra
. . . . . . . . . . . . .V4-T2-185M-Frame (300 800 Amperes). . . . . . . . . . . . . . . . . .V4-T2-211N-Frame (400 1200 Amperes). . . . . . . . . . . . . . . . .V4-T2-222R-Frame (800 2500 Amperes) . . . . . . . . . . . . . . . . .V4-T2-237Motor Circuit Protectors (MCP) . . . . . . . . . . . . . . . .V4-T2-256Motor Protection Circuit Breakers (MPCB). . . . . . . .V4-T2-267Type ELC Current Limiter Attachment (Size 0 4) . . . . .V4-T2-269Current Limiting Circuit Breaker Module . . . . . . . . . . .V4-T2-270Internal Accessories. . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-273External Accessories . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-304Types GHB and HGHB Bolt-On Standards and CertificationsThese breakers meet the requirements of Federal Specification W-C-375b as Type GHB, 120 and 240 V:Single-pole: Class 11aTwo-, three-pole: Classes 10b, 11b, 12b, 14b, 15bUL/CSAType GHB, 277 and 480Y/277V:Single-pole: Classes 12c, 13aTwo-, three-pole: Class 13bType HGHB 277VType GHQ 277V Volume 4Circuit ProtectionCA08100005EAugust 2016www.eaton.comV4-T2-127 Molded Case Circuit BreakersSeries CProduct SelectionType GHB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units Type HGHB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Uni
4 ts Notes480Y/277 V, circuit breakers (Ty
ts Notes480Y/277 V, circuit breakers (Type GHB) not suitable for three-phase delta (480 V).Single-pole breakers can be applied in DC systems from 15 through 70 amperes; 80 through 100 amperes devices are not suitable for DC application.Use two outside poles.Uses 0.190 (4.83) 32 screw type clamp terminals.Add suffix HID for High Intensity Discharge (HID) applications. 15 and 20 ampere, single-pole are SWD rated.15 and 20 ampere, single-pole are SWD rated.Continuous Ampere Ratingat 40 °C277/480 Vac Maximum, 125 Vdc Maximum 277/480 Vac Maximum, 125/250 Vdc Maximum277/480 Vac Maximum, 125/250 Vdc Maximum Single-PoleTwo-PoleCatalogCatalogNumberCatalogNumberGHB1015 GHB2015 GHB3015 GHB1020 GHB2020 GHB3020 GHB1025GHB2025GHB3025GHB1030GHB2030GHB3030GHB1035GHB2035GHB3035GHB1040GHB2040GHB3040GHB1045GHB2045GHB3045GHB1050GHB2050GHB3050GHB1060GHB2060GHB3060GHB1070GHB2070GHB3070GHB1080GHB2080GHB3080GHB1090GHB2090GHB3090100GHB1100GHB2100GHB3100Continuous Ampere Rating at 40 °C277 Vac Maximum, 125 Vdc MaximumSingle-PoleCatalog HGHB1015 HGHB1020 HGHB1025HGHB1030 Typical GHB V4-T2-130Volume 4Circuit ProtectionCA08100005EAugust 2016www.eaton.com Molded Case Circuit BreakersSeries CDimensionsApproximate Dimensions in Inches (mm)GHB-Frame, Three-Pole 3.00(76.2) 2.63(66.7) 4.00(101.6) Front ViewSide Vi