Dampers for Vibration Control Presenting by JITHINK MTech Machine Design Roll No 9 Guided by Dr KGJolly HOD Mechanical Dept INTRODUCTION Viscoelastic and fluid film dampers ID: 534623
Download Presentation The PPT/PDF document "Self-Sensing Active Magnetic" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
Slide1
Self-Sensing Active MagneticDampers for Vibration Control
Presenting by, JITHIN.K M-Tech, Machine Design Roll No: 9
Guided by,
Dr.
K.G.Jolly
H.O.D
Mechanical Dept.Slide2
INTRODUCTION
Viscoelastic and fluid film dampers.Passive, semi-active and active dampers.Electromechanical dampersAbsence of all fatigue and tribology issues.Smaller sensitivity to the operating conditions.
Wide possibility of tuning even during operation.
Predictability of the behavior.
Active magnetic bearingsShaft is completely supported by electromagnets
2Slide3
Active magnetic dampersRotor is supported by mechanical means and the electromagnetic actuators are used only to control the shaft vibrations.
The combination of mechanical suspension with an electromagnetic actuator is advantageous.The system can be designed to be stable even in open loop.
Actuators are smaller compared to AMB configuration.
Our aim is to investigate self sensing approach in the case of AMD configuration.
The self sensing system is based on the Luenberger observer.
Parameters can be obtained in two different ways
Nominal ones and identified ones.
3Slide4
Modeling and Experimental Setup
A single degree of freedom mass spring oscillator actuated by two opposite electromagnets.4Adoption of mechanical stiffness in parallel to electromagnets allows to compensate the -
ve
stiffness induced by electromagnets.
The back-electromotive force produced can be exploited to estimate mechanical variables from the measurement of electrical ones.
Fig. 1 Model
Nominal modelSlide5
This leads to the so-called selfsensing configuration that consists in using the electromagnet either as an actuator and a sensor.
Voltage and current are used to estimate the airgap.Each electromagnet can be considered as a two-port element (electrical and mechanical).The energy stored in the electromagnet
j
is expressed as:
5
where the force can be obtained as
(1)
(2)Slide6
6
The total flux and the coil current are
related by a nonlinear function
(3)
where is the radial airgap of electromagnet
j
(4)
where is the nominal airgap
Owing to Newton’s law in mechanical domain, the
Faraday and
Kirchoff
law in the electrical domain, the
dynamic equations of the system are
(5)Slide7
7
where, R = coil resistance
= voltage applied to electromagnet
j
=
disturbance force applied to the mass
The system dynamics is
linearized
around a working
point corresponding to a bias voltage imposed to both
electromagnets
(6)
where is the initial force generated by the electromagnet due to the current .Slide8
8
The resulting
linearized
state space model is
where A,B and C are dynamic, action and output matrices respectively, defined as
(7)
(8)
with the associated input and output state vectors
and . Slide9
9The terms in the matrices derive from the linearization of
the nonlinear functions defined in eqs. (2) and (3)
(9)
where are the inductance, the current-force factor, the back-electromotive force factor, and the negative stiffness of one electromagnet respectively.
Assuming that ferromagnetic material of the actuator does not saturate, has infinite magnetization and there is no magnetic leakage in the air gap,
(10)Slide10
10
Where , characteristic factor of electromagnets.
S = cross-sectional area of the magnetic circuit.
The presence of a mechanical stiffness large enough to overcome the negative stiffness of the electromagnets makes the linearization point stable and compels the system to oscillate about it.
As far as the linearization is concerned, the larger is stiffness
k
relative to | |, the more negligible the nonlinear effects become.Slide11
11Identified Model
The system used is a test rig used for static characterization of radial magnetic bearings.
Fig. 2 Photo of the test rig
This rig consists in a horizontal arm hinged at one extremity with a pivot and actuated with a single axis magnetic bearing.
Six springs in parallel are placed to provide a stabilizing stiffness to the system.
Fig. 3 Test rig schemeSlide12
12It consist of two electromagnets, power amplifier,
Bently Proximitor eddy current sensor and current sensor.Damping may be introduced into the structure by simply feeding back the position sensor signal by means of a proportional-derivative controller.Two sets of parameters have been used to build the models.
Based on expression
Have been identified experimentally under two assumptions.
k,
c
, and m are determined from physical dimensions, direct measurements, and impact response in open-circuit electromagnets conditions.
The electromechanical parameters and are equal.Slide13
13
The proposed identification procedure isObtain the transfer function admittance in Fig. 4.Measure the resistance value R
at low frequency 1 Hz in our case.
Identify based on the high frequency slope of
Identify such that the zero-pole pair due to the mechanical resonance corresponds to the experimental ones.Slide14
14
The good correlation between the experimental and identified plots validates the proposed procedure.Slide15
15Controller unit
To introduce active magnetic damping into the system.The control is based on the Luenberger observer approach.
It consists in estimating in real-time the unmeasured states
- displacement and velocity from the processing of the
measurable states i.e. the current.Slide16
16Experimental results
The open-loop voltage to displacement transfer function obtained from the model and experimental tests are compared.The same transfer functions in closed-loop operation with the controller designed are compared in the case of identified parameters.In this case, the correspondence is quite good, which corroborates the control approach, and validates the whole procedure.Slide17
17Slide18
18The damping performances are evaluated by analyzing the time response of the closed-loop system when an impulse excitation is applied to the system.
The controller based on the identified electromechanical parameters give better results than the nominal model.Good damping can be conveniently achieved for active magnetic dampers obtained with the simplified model.This controller does not destabilize the system, as it is the case for full suspension self-sensing configurations.Slide19
19Slide20
20CONCLUSION
The study of an observer-based self-sensing active magnetic damper has been presented both in simulation and experimentally.The closed-loop system has good damping performances than open-loop system.The modeling approach and the identification procedure have been validated experimentally comparing the open-loop and the closed-loop frequency response to the model.
The self-sensing configuration provides good robustness performances even for relatively large parameter deviations.Slide21
21References
A.Tonoli, N. Amati, M. Silvagni, 2008, “Transformer Eddy Current Dampers for the Vibration Control,” ASME J. Dyn
. Syst., Meas., Control, 130, p.031010.
E. H.
Maslen, D. T. Montie and T. Iwasaki, 2006, “Robustness Limitations in Self-Sensing Magnetic Bearings,” ASME J.
Dyn
. Syst., Meas., Control, 128, pp. 197–203.V.P.Singh
, “Mechanical Vibrations”.Slide22
22Thank you…