Detection Scheme of  Single Shot Time Resolved X-ray Emission Spectroscopy of Chemical Detection Scheme of  Single Shot Time Resolved X-ray Emission Spectroscopy of Chemical

Detection Scheme of Single Shot Time Resolved X-ray Emission Spectroscopy of Chemical - PowerPoint Presentation

thousandnike
thousandnike . @thousandnike
Follow
343 views
Uploaded On 2020-06-30

Detection Scheme of Single Shot Time Resolved X-ray Emission Spectroscopy of Chemical - PPT Presentation

Kathleen R Geyer August 12 2010 Mentor Dennis Nordlund SULI Presentation August 12 2010 Kathleen Geyer geyerslacstanfordedu UHV End Station Soft Xrays 012 to 12 KeV PES XAS and XES ID: 789867

kathleen geyer slac stanford geyer kathleen stanford slac 2010 suli august presentation smile presentationaugust ideal ssrl background run gain

Share:

Link:

Embed:

Download Presentation from below link

Download The PPT/PDF document "Detection Scheme of Single Shot Time Re..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

Detection Scheme of Single Shot Time Resolved X-ray Emission Spectroscopy of Chemical Dynamics at LCLS

Kathleen R. GeyerAugust 12, 2010Mentor: Dennis Nordlund

SULI PresentationAugust 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Slide2

UHV End Station

Soft X-rays: 0.12 to

12 KeVPES, XAS, and XES

Slide3

How it Works

Slide4

How it works

Slide5

Ideal Smile

SULI Presentation

August 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Slide6

Ideal Spectrum

SULI Presentation

August 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Slide7

Adimec Opal-1000m/Q

High Speed CCD Camera1 Megapixel resolution

SULI PresentationAugust 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Slide8

Camera SettingsFocus

Field of viewMinimizing BackgroundFPSExposure timeGain Settings

SULI PresentationAugust 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Slide9

Gain Setting

Gain = Number of electrons per pixel/number of counts per pixel (ADUs)

SULI Presentation

August 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Slide10

SSRL Run: Smile

SULI Presentation

August 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Slide11

SSRL Smile

Ideal Smile

Slide12

SSRL Run: Spectrum

SULI Presentation

August 12, 2010

Kathleen Geyer

geyer@slac.stanford.edu

Raw Data

Removed Background

Slide13

ConclusionAveraging of images using background discriminator does not work

Next Step: Blob finder program