/
Bartek Szejna, OASIS team Bartek Szejna, OASIS team

Bartek Szejna, OASIS team - PowerPoint Presentation

yoshiko-marsland
yoshiko-marsland . @yoshiko-marsland
Follow
382 views
Uploaded On 2016-07-17

Bartek Szejna, OASIS team - PPT Presentation

Round table 28052013 HyperManager Spinnaker project PLAN Spinnaker project EConnectWare ECW HyperManager upon ECW HyperManager Indicators Implementation Demo Conclusion 2 PLAN Spinnaker project ID: 408943

hypermanager ecw spinnaker gateway ecw hypermanager gateway spinnaker site ecwhypermanager plan equipments projecteconnectware indicatorsimplementationdemoconclusions customer indicators project rfid local software state central

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Bartek Szejna, OASIS team" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

Bartek Szejna, OASIS teamRound table, 28/05/2013

HyperManager Spinnaker projectSlide2

PLAN

Spinnaker projectEConnectWare (ECW)HyperManager upon ECW

HyperManager IndicatorsImplementationDemoConclusion2Slide3

PLAN

Spinnaker projectEConnectWare (ECW)

HyperManager upon ECWHyperManager IndicatorsImplementationDemo

Conclusions3Slide4

Spinnaker project

Transform the current state of the art in RFID-based systems and enable more widespread adoption

of the technology, particularly in retail and healthcare sectorsImprove the performance and real-time interconnectivity of wireless-sensing systems Throughout

the supply chain, from manufacturing, distribution, and retail through to the end customer experience.Lead by TAGSYS8 research labs 4 industrial entities

4Slide5

Spinnaker project

Partners:INSIDE SecureLegrand

High-frequency communicationINRIA - OASISINP Grenoble – LCIS – ORSYSMicroelectronics Center of ProvenceInstitut d’électronique et de télécommunications de Rennes

François Rabelais UniversityESEO SchoolUniversity Pierre & Marie Curie LaboratoryAcoustics Laboratory of the University of MaineUniversité Paris-Est Marne-la-Vallée – ESYCOM

5Slide6

PLAN

Spinnaker projectEConnectWare (ECW)

HyperManager upon ECWHyperManager IndicatorsImplementationDemo

Conclusions6Slide7

Econnect

ware

By TagsysRFIDNew generation for a cloud hosted middlewareGather RFID

information, collected by RFID readers deployed on the client sites (factories, warehouses, shops, etc.)Set of advanced management and administrative functionsBuilt using Scalagent JMS

Configuration consist of a server and several gateways7Slide8

PLAN

Spinnaker project

EConnectWare (ECW)HyperManager upon ECWHyperManager IndicatorsImplementationDemo

Conclusions8Slide9

HyperManager

HyperManager in Spinnaker project (abstraction level)

9

ECW

HMOtherPartnersBare metal, RFID, etc..SoftwareSlide10

HyperManager

Monitor and to act automatically on each element of the architecture

10

Equipments

EquipmentsEquipmentsEquipmentsHMCustomerECW CentralGateway

L2

HM

Site

ECW Site

Gateway

HM

Site

ECW Site

Gateway

L1

HM

Gateway

ECW

Gateway

HM

GW

ECW

GW

HM

GW

ECW

GW

HM

GW

ECW

GW

L0

HM

Supervisor

L3

Monitor the behavior of local gateway events

Report on the health of the ECW Gateway to the upper layer

Monitoring the behavior

and state of local gateways

Ensuring traceability of local gateways behaviour

Handle failure in an automatic manner

Handling configuration and reconfiguration

Orcheastring firmware and software deployment and updates

Offering client oriented facilities

Managing software versioning

Provide cloud-base hosting for customer’s central

servers, as an alternative to local hosting on the customer premisesSlide11

HyperManager

Component model

11

HM

SiteL1HMGatewayHMGWEquipmentsEquipments

Equipments

Equipments

ECW Central

Gateway

ECW Site

Gateway

ECW Site

Gateway

ECW

Gateway

ECW

GW

ECW

GW

ECW

GW

L0

L2

HM

Customer

HM

Site

HM

GW

HM

GW

HM

Supervisor

L3Slide12

HyperMANAGER USE CASE

12Slide13

PLAN

Spinnaker project

EConnectWare (ECW)HyperManager upon ECWHyperManager IndicatorsImplementationDemo

Conclusions13Slide14

HyperManager Indicators

Different Indicators per levelMachine (Cpu, Memory, ...)Mediation (components, JMS queues,...)

HMIEPCIS errorsAccessibility by:JMXDBNative library

14Slide15

PLAN

Spinnaker project

EConnectWare (ECW)HyperManager upon ECWHyperManager IndicatorsImplementationDemo

Conclusions15Slide16

HyperManager - implementation

Upon ProActive Parallel Suite

Indicators state exchange between levels:PullPush (critical events)19/42 Indicators implemented (25 available) Automatic event handling – 2 casesEvents stored in DB (Hibernate + SQLite) on L1JNI, Plain SQL

16Slide17

HyperManager - implementation

17

HM

Customer

Host with ECW componentsSite1RMHMSiteGW1GW2HMGW

HM

GW

GW3

HM

GW

Site2Slide18

PLAN

Spinnaker project

EConnectWare (ECW)HyperManager upon ECWHyperManager IndicatorsImplementationDemo

Conclusions18Slide19

DEMO

Main starting host (Antofagasta)4 virtual machines2 per 1 site

Critical events simulation on Hypermanager levelTemporary solutionNX technology19

JMX

HMECWSimulationLET’S GO!Slide20

PLAN

Spinnaker project

EConnectWare (ECW)HyperManager upon ECWHyperManager IndicatorsImplementation

DemoConclusion20Slide21

Conclusion & FUTURE WORK

Extend a list of implemented indicators

GUI improvementImplement other remaining levelsLack of support from Tagsys 

21Slide22

Questions

22