frame2 and 3 1 Higher pressure drop for frame 3 Frame 2 nd design with heater 31103 Heaters resistance inlet 598 589 586 59 604 outlet 1053 1035 1032 1034 1062 ID: 914321

design frame 3111 heater frame design heater 3111 3rd power device 31107 resistance heaters pt100 digital 557 3100 857

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "Hydraulic qualification" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

Hydraulic qualificationframe2 and 3

1

Higher

pressure drop for frame 3

Slide2

Frame 2nd design with

heater #31103

Heaters resistance

inlet

59.8

58.958.65960.4outlet105.3103.5103.2103.4106.2104.7103.2102.6103105.1inlet59.158.1~5858.9outlet

2

Massflow

: 10 g/s

Cooling

unit

setpoint

: -20°C

Slide3

Frame 3rd design (second device

) with heater #31107

3

Massflow

: 10 g/s

Cooling unit setpoint : -20°CHeaters resistanceinlet~57.857.557.959.3outlet98.4100.396.3100.3102.9102.1100.699.7100102.2inlet56.1~56.556.657.8

outlet

Slide4

Frame 3rd design (second device) with

heater #31107

4

Heaters resistance

inlet

~57.857.557.959.3outlet98.4100.396.3100.3102.9102.1100.699.7100102.2inlet56.1~56.556.657.8

outlet

Graph showing behavior of right digital part if we assume that all heaters are working

Slide5

Frame 3rd design (second device) with

heater #31107

5We noticed that there is a ∆T of almost 6°C between the temperatures of the digital and the analog part.

We think that it’s due to the difference of about 2

Ω

between the digital Pt100 and the sensor Pt100 (resistance of the lines).Pt100 resistanceinlet111.2111.3111.4111.3111.3outlet113.4113.1113.1113112.2inlet111.4111.3111.3111.3111.2outletAfter correction, we obtain the following graph :

Slide6

Frame 3rd design (second device) with

heater #31107

Power values taken with the power supplies monitoring on LabVIEW

Power values taken with the reading of

multimeters

for the current and reading of the power supply display for the voltage6