PAHE PROJECT PAHE PROJECT

PAHE PROJECT - PDF document

cadie
cadie . @cadie
Follow
343 views
Uploaded On 2021-07-02

PAHE PROJECT - PPT Presentation

Vesa Riikonen Virpi Kouhia Lauri Pyy Joonas Telkk ID: 851394

experiment containment water flow containment experiment flow water interim vessel heat pool kyt2022 safir2022 seminar joint temperature sparger system

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "PAHE PROJECT" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 PAHE PROJECT Vesa Riikonen, Virpi Kouhia
PAHE PROJECT Vesa Riikonen, Virpi Kouhia, Lauri Pyy, Joonas Telkkä JOINT INTERIM SEMINAR OF SAFIR2022 AND KYT2022 LUT University Nuclear Engineering PASI FACILITY Joint Interim seminar of SAFIR2022 and KYT2022 PASI represents an open passive heat removal loop The reference system is the passive heat removal system for containment (PHRS - C) designed for the AES - 2006 type PWR PASI comprises containment vessel, heat exchanger, riser and downcomer lines, sparger, water pool ▪ Height

2 scaling 1:2 → height of the loop 9.9
scaling 1:2 → height of the loop 9.9 m ▪ Maximum pressure inside containment 5 bar ▪ Maximum temperature inside containment 170 ▪ C ▪ Higher water pool and sparger NATURAL CIRCULATION EXPERIMENT Joint Interim seminar of SAFIR2022 and KYT2022 A natural circulation experiment with the low sparger and water pool to characterize the basic facility operation modes in 2018 ▪ Flow oscillations were observed in the experiment, which ended before the system reached quasi - steady

3 two - phase flow conditions ▪ A new
two - phase flow conditions ▪ A new test was done in 2019 to test if the flow oscillations will even out when the temperature in the system increases to the saturation temperature of the water pool ▪ Pre - test calculations with APROS were done with the PASI simulation model provided by VTT to find experiment parameters In the new experiment, the loop mass flow rate fluctuated strongly (average oscillation frequency about 0.01 Hz) Oscillation continued approximately for one ho

4 ur, until the end of the experiment Ass
ur, until the end of the experiment Assumed attenuation of the flow oscillation was not achieved in this experiment EXPERIMENTS FOR VTT PROJECTS (1/2) Joint Interim seminar of SAFIR2022 and KYT2022 EXPERIMENT WITH STEAM (high sparger and water pool) To observe the natural circulation behavior of the PASI facility under different steam mass flow rates to the containment How much condensate can be collected from the bottom of the containment vessel and from the walls of the containmen

5 t vessel Experiment began from cold cond
t vessel Experiment began from cold conditions and steam supply flow was increased stepwise starting from a low value Experiment contained several steps, between each step the conditions in the facility was let stabilize to get as good steady state conditions as reasonable possible It was possible to measure the amount of condensate from the heat exchanger, but the wall condensation was minimal (most of the time it was below the measurement range of the smallest available flow measu

6 rement device) Temperatures in the conta
rement device) Temperatures in the containment stratified - most likely due to the condensate in the bottom of the containment EXPERIMENTS FOR VTT PROJECTS (2/2) Joint Interim seminar of SAFIR2022 and KYT2022 HEAT LOSS EXPERIMENT ( high sparger and water pool) Heat losses from the containment Loop was empty, and the vessel was heated up using electrical heaters inside the vessel instead Only minor temperature stratification inside the containment vessel was observed Inner and outer

7 wall temperatures were clearly higher at
wall temperatures were clearly higher at the lowest elevation The containment tank temperature at the lowest elevation was closer to the wall temperatures EXPLOITATION OF THE RESULTS AND THE SAFETY SIGNIFICANCE Joint Interim seminar of SAFIR2022 and KYT2022 Different organizations can use data in the development and validation of system and CFD codes for the safety analyses of nuclear power plants Project maintained and extended the research expertise needed for the experimental work