/
PRINTED IN JAPAN 2008  NIHON SEIMITSU SOKKI CO LTD PRINTED IN JAPAN 2008  NIHON SEIMITSU SOKKI CO LTD

PRINTED IN JAPAN 2008 NIHON SEIMITSU SOKKI CO LTD - PDF document

elise
elise . @elise
Follow
348 views
Uploaded On 2021-07-05

PRINTED IN JAPAN 2008 NIHON SEIMITSU SOKKI CO LTD - PPT Presentation

AAA batteries at FINGER no wires 4075 resistance NIHON SEIMITSU SOKKI CO LTD 250813 Nakago Shibukawa Gunma 3770293 JapanECRepresentative JPI Trading GmbH Holzbrücke 7 20459 Hamburg Germany ID: 853889

spo2 measurement 800 approximately measurement spo2 approximately 800 finger rate pulse environment condensation circumference patient accuracy performance 100 nihon

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "PRINTED IN JAPAN 2008 NIHON SEIMITSU SO..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 PRINTED IN JAPAN 2008 © NIHON SEIMITSU S
PRINTED IN JAPAN 2008 © NIHON SEIMITSU SOKKI CO., LTD. AAA batteries at FINGER no wires 40-75 resistance NIHON SEIMITSU SOKKI CO., LTD. 2508-13 Nakago Shibukawa Gunma 377-0293 JapanEC-Representative: JPI Trading GmbH, Holzbrücke 7, 20459 Hamburg, Germany 040-82 22 80 510web site http://www.nissei-jp.com ೔ຊਫ਼ີଌثגࣜձࣾ No Wire ConnectionsWith no wires to connect, BO-800 embodies convenient and handy measurement of %SpO2.his or her finger, no matter how big or small it is as long as its circumference is not over 75 mm or below 40 mm. The displayed. Soon after, you will be able to confirm patient's %SpO2. Take off BO-800 from your patient's finger when you are done with measurement. BO-800 will automatically stops measurement and turns off. That is how easy underestimate its accuracy, performance and durability. With light emission element developed by our own and high optical sensitivity of BO-800. Dual-gain-cont

2 rol and auto-off-set function with DAC a
rol and auto-off-set function with DAC are adapted for measurement stability. Breath-controlled-measurement Model BO-800Principle of measurement Double wavelength lights absorption methodIndicator LCDMeasuring range %SPO2 0 to 100 % pulse rate 30 to 240 pulses/min (pulse rate)Accuracy %SPO2 70~100%; ±2% pulse rate ±3%/±1 digitPower supply 2 alkaline AAA (LR03) batteriesPower consumption approximately 0.09WOperating environment +10°C to +40°C, 30% to 85% RH (no condensation)Storage environment -20°C to +60°C, 10% to 95% RH (no condensation)Applicable finger circumference 40 to 75 mmDimensions approximately 61(H) X 34 (W) X 32(D) mmWeight approximately 37g without batteriesbattery life approximately 40 hours of continuous use, (4800 times of 30-second-spot measurements)Water resistance IPX2 (IEC 60601-1)Specifications are subject to change without prior notice due to improvements in performance and quality.